Light quenching of fluorescence: a new method to control the excited state lifetime and orientation of fluorophores.

Experimental studies have recently demonstrated that fluorescence emission can be quenched by laser light pulses from modern high-repetition rate lasers, a phenomenon we call "light quenching." In this overview article, we describe the possible effects of light quenching on the steady-state and time-resolved intensity and anisotropy of fluorophores. One can imagine two classes of experiments. Light quenching can occur within the single excitation pulse, or light quenching can be accomplished with a second time-delayed quenching pulse. The extent of light quenching depends on the amplitude of the emission spectrum at the quenching wavelength. Different effects are expected for light quenching by a single laser beam (within a single laser pulse) or for a time-delayed quenching pulse. Depending upon the polarization of the light quenching beam, light quenching can decrease or increase the anisotropy. Remarkably, the light quenching can break the usual z-axis symmetry of the excited state population, and the measured anisotropy (or polarization) depends upon whether the observation axis is parallel or perpendicular to the propagation direction of the light quenching beam. The polarization can increase to unity under selected conditions. Quenching with time-delayed light pulses can result in step changes in the intensity or anisotropy, which is predicted to result in oscillations in the frequency-domain intensity and anisotropy decays. These predicted effects of light quenching, including oscillations in the frequency-domain data, were demonstrated to occur using selected fluorophores. The increasing availability and use of pulsed laser sources requires consideration of the possible effects of light quenching and offers the opportunity for a new class of two-pulse or multiple-pulse time-resolved experiments where the sample is prepared by the excitation pulse and subsequent quenching pulses to modify the excited state population, followed by time- or frequency-domain measurement of the optically prepared excited fluorophores.

Fluorescence Polarization↗

Fluorescence study of conformational flexibility of RNase S-peptide: distance-distribution, end-to-end diffusion, and anisotropy decays.

Frequency-domain fluorescence resonance energy transfer and anisotropy measurements were performed to characterize conformational dynamics of an analog of the RNase S-peptide (residues 1-20). Trp was used as a donor by replacing Phe 8, and a dansyl acceptor group was introduced at position 1 or 18. The distance-distribution parameters, half width of the distribution, end-to-end diffusion coefficient, and to some extent anisotropy decays were sensitive to changes in the S-peptide conformation. The observed mean distance of about 13-14 A between residues 1 and 8 in the presence of 50% TFE and when bound to RNase S-protein is in reasonable accord with the X-ray structure of RNase. The mean distance of 9.3 A between residues 8 and 18 in the presence of 50% TFE is, however, significantly smaller than 15.3 A found for the S-protein complex. The half-width of the distance distribution increased from about 9 to 18 A for residues 1-8 and from about 6 to 14 A for segment 8-18 with the loss of helical structure. The half-widths of 9 A in the case of 1-8 segment when peptide is helical suggests the presence of considerable conformational heterogeneity. Also, the 14 A half-width for segment 8-18 when it is random-coil is smaller than that expected for a random coil 11-residue segment. The donor-to-acceptor diffusion coefficients were less than 1 x 10(-7) cm2/s at 2 degrees C for both segments and increased to 1-2 x 10(-6) cm2/s at 35 degrees C.(ABSTRACT TRUNCATED AT 250 WORDS)

Dansyl Compounds↗

Time-resolved energy transfer measurements of donor-acceptor distance distributions and intramolecular flexibility of a CCHH zinc finger peptide.

Time-resolved frequency-domain fluorescence energy transfer measurements have been used to investigate the solution structure of a single-domain CCHH-type zinc finger peptide. These measurements reveal not only the range of accessible distances for a given donor-acceptor pair within the molecule but also the degree of conformational flexibility that occurs in solution. Two donor-acceptor (D-A)-pair zinc finger peptides have been synthesized. A single tryptophan residue located at the midpoint of the sequence was the energy donor for two different acceptors. One acceptor, attached at the amino terminus was a 5-(dimethylamino)-1-naphthalenesulfonyl (DNS) group; the second acceptor was a 7-amino-4-methyl-coumarin-3-acetyl (AMCA) group, attached to the epsilon-amino function of a carboxy-terminal lysine residue. Distance distributions and the mutual site-to-site diffusion coefficients were determined for these two D-A-labeled peptides under zinc-bound, metal-free, and denatured conditions. The D-A distance distributions determined for these two peptides under metal-free and zinc-bound conditions indicated a shorter distance and a unique conformation (narrow distribution) when metal was bound and a longer distance with greater conformational flexibility when metal ion was absent. No site-to-site diffusion was detected for the zinc-bound peptide, whereas an appreciable amount of diffusion was measured for both metal-free and denatured peptide. Anisotropy measurements on the peptides indicated increased flexibility of all regions of the peptide chain in the absence of zinc and a more compact, less flexible structure when zinc was bound. It was concluded from these results that the metal-bound conformation represents a unique, well-defined structure. Comparison of distance distributions measured for metal-free and denatured peptide indicated that there is some residual structure present in the metal-free peptide.

Amino Acid Sequence↗

Optical measurements of pH using fluorescence lifetimes and phase-modulation fluorometry.

We measured the pH-dependent fluorescence decay times of the seminaphthofluoresceins (SNA-FL), seminaphthorhodafluors (SNARF), and BCE-CF using phase-modulation fluorometry. The phase and modulation values were found to be strongly pH-dependent in the physiological pH range, over the easily accessible range of light modulation frequencies from 10 to 300 MHz, making these probes useful as lifetime-based pH sensors. The phase and modulation values are dependent on excitation and emission wavelength as well as pH. This dependence allows the range of pH sensitivity to be chosen by selection of the wavelength(s) and enables increased precision of the pH measurements by use of phase and/or modulation measurements at several wavelengths. These probes can be excited using a a green He-Ne laser at 543 nm, which allows their use in low cost instrumentation. Phase and modulation measurements are especially suitable for sensing applications because they are insensitive to the changes in signal intensity that result from photobleaching, probe washout, and/or light losses.

Fluoresceins↗

Phase-resolved fluorescence lifetime measurements for flow cytometry.

A flow cytometer capable of measuring fluorescence lifetimes by the phase shift method has been built and evaluated. Under optimal conditions, the resolution of the fluorescence lifetime measurement is shown to be under 200 picoseconds. Pulse intensity variations are normalized using limiting amplifiers and electronic filtering. Normalization of signal intensities provides a lifetime measurement that is independent of fluorescence intensity over at least a 50-fold (17 dB) range in fluorescence intensity. The fluorescence lifetimes of unbound dye, fluorescent beads, cells stained with ethidium bromide, propidium iodide, and phycoerythrin-conjugated monoclonal antibodies have been measured. The fluorescence lifetimes measured for these particles are well correlated with lifetime measurements made using a standard fluorimeter. Cells stained with ethidium bromide and propidium iodide at various nucleotide-to-dye ratios are shown to exhibit similar behavior to static cuvette measurements. The fluorescence lifetime parameter is also shown to resolve phycoerthyrin fluorescence from propidium iodide fluorescence.

Cells, Cultured↗

Homogeneous model immunoassay of thyroxine by phase-modulation fluorescence spectroscopy.

We describe a homogeneous competitive model immunoassay for determination of thyroxine by multifrequency phase-modulation fluorescence. Using a nonradiative energy transfer transduction mechanism, B-phycoerythrin conjugated to thyroxine is the energy donor and a carboxymethylindocyanine dye conjugated to anti-thyroxine antibody is the energy acceptor. Energy transfer from B-phycoerythrin to the acceptor results in a decreased lifetime and/or phase angle. The fluorescence lifetime change reflects the extent of energy transfer. In the competitive immunoassay format, the donor-thyroxine conjugate and an analytical sample of thyroxine compete for acceptor-antibody binding sites, resulting in a phase angle change which is dependent on the amount of thyroxine in the sample. Dose-response curves of phase angle versus thyroxine concentration are comparable to steady-state intensity curves. Since phase-modulation lifetime measurements are largely independent of total signal intensity, sources of optical interference are minimized. The potential for whole blood measurements exists since the energy transfer lifetime method can be extended to longer wavelengths.

Antibodies↗

Styryl-based wavelength-ratiometric probes: a new class of fluorescent calcium probes with long wavelength emission and a large Stokes' shift.

We describe the chemical synthesis and fluorescence spectral characterization of a styryl-benzothiazole probe which contains the Ca2+ chelating group BAPTA as an integral part of the chromophoric system. The visible absorption spectrum of this probe displays a dramatic shift in the long wavelength maxima from 508 to 407 nm upon complexation with Ca2+, with a Ca2+ dissociation constant of 1.5 microM. The emission maximum centered at 615 nm is well shifted from the absorption. The emission spectrum displays a small blue shift upon binding Ca2+, allowing this probe to possibly be used as an emission wavelength-ratiometric probe using a single-excitation wavelength. This probe is likely to be the first of a series of long-wavelength ratiometric Ca2+ probes whose structure can be modified for improved quantum yield or altered Ca2+ affinity.

Calcium↗

End-to-end diffusion coefficients and distance distributions from fluorescence energy transfer measurements: enhanced resolution by using multiple acceptors with different Förster distances.

We measured distance distributions and end-to-end diffusion coefficients of donor-acceptor pairs linked by a flexible methylene chain using frequency-domain fluorescence energy transfer measurements. The donor was an indole group, and two acceptors with different Förster distances were used. The uncertainties in the recovered parameters describing the end-to-end distance distribution and diffusion coefficient were rather large when each donor-acceptor pair was analyzed separately. It was not possible to resolve distance distributions in the presence of intra-molecular diffusion when the Förster distance was comparable to the mean and half-width of the distribution. Global analysis using two acceptors dramatically improved the resolution. Surprisingly, the Förster distances need not be very different, and a 20% difference between the two R0 values resulted in substantial improvements in resolution. Both the simulations and the experiments suggest the benefit of using global analysis with different Förster distances to obtain reliable distance distribution parameters in the presence of diffusion.

Benzenesulfonates↗

Characterization of p-bis(O-methylstyryl)benzene as a lifetime and anisotropy decay standard for two-photon induced fluorescence.

We describe the fluorescence spectral properties of p-bis(O-methylstyryl)benzene (bis-MSB) as a standard for time-resolved measurements of two-photon induced fluorescence. Bis-MSB displays the same single exponential intensity decay in several solvents for one- and two-photon excitation. The anisotropy decay displays the same single correlation time of one- and two-photon excitation. The amplitudes of the anisotropy decay are distinct for one- and two-photon excitation. At some excitation wavelengths the anisotropy amplitude appears to be solely the result of one- and two-photon photoselection, but at shorter wavelengths the anisotropy amplitudes are not related by single constant factor. The absorption range of bis-MSB makes it a suitable standard for one- and two-photon excitation of intrinsic protein fluorescence and extrinsic fluorophores.

Fluorescence↗

Intensity and anisotropy decays of [Leu5] enkephalin tyrosyl fluorescence by 10 GHz frequency-domain fluorometry.

The technique of 10 GHz frequency-domain fluorometry was used to resolve the complex picosecond intensity and anisotropy decays of the tyrosyl emission of [Leu5] enkephalin. Enhanced resolution of anisotropy decay was obtained by using acrylamide quenching of the tyrosyl fluorescence and global analysis of the frequency-domain anisotropy data obtained with different amounts of acrylamide. The data indicates a 44 ps correlation time for local tyrosine motions, and a 219 ps correlation time for overall rotational diffusion of the pentapeptide. Our data are consistent with an initial loss of fluorescence anisotropy from r0 = 0.4 to a value of r0 = 0.326 occurring during the first two picoseconds after excitation.

Acrylamides↗

Calcium-dependent fluorescence lifetimes of Indo-1 for one- and two-photon excitation of fluorescence.

We characterized the fluorescence intensity decays of Indo-1, which is commonly used as an emission wavelength-ratiometric calcium probe. The apparent lifetime of the long-wavelength side of the emission of Indo-1 is dependent on Ca2+. This long-wavelength emission displays the characteristics of an excited-state reaction, that is, a negative preexponential component in the multiexponential analysis. The emission spectra and lifetime of Indo-1 appear to be identical for one-photon and two-photon excitation at 351 and 702 mn, respectively, suggesting that the relative one- and two-photon cross sections are similar for the calcium-free and calcium-bound forms of Indo-1. Also, the two-photon cross section of Indo-1 is relatively high, about 4 x 10(-49) cm4 s/photon molecule at 690 nm for both the calcium-free and calcium-bound forms. Hence, Indo-1 can be used for calcium imaging based on one- or two-photon excitation, using either emission wavelength ratios or lifetime imaging methods.

Calcium↗

Frequency domain imaging of absorbers obscured by scattering.

Multiple pixel, frequency domain measurements of phase shift, theta, and modulation, m, in a phantom containing an absorber obscured by a relatively non-absorbing scattering solution are presented in combination with a theory of photon migration imaging. Results employing a single point source show that two dimensional theta measurements made in the presence (theta presence) and in the absence (theta absence) of an absorber can be used to create delta theta images. delta theta (theta absence-theta presence) images can be used to detect as well as locate the three dimensional position of the absorber. Images of mpresence measured in the presence of the absorber normalized by mabsence also provided detection and two dimensional location of its position. Images of % mpresence/mabsence at higher modulation frequencies provided greater resolution as predicted by photon migration theory. Neither theta nor m images alone could be used to detect or locate the presence of the absorber.

Light↗

Fluorescence lifetime imaging.

We describe a new fluorescence imaging methodology in which the image contrast is derived from the fluorescence lifetime at each point in a two-dimensional image and not the local concentration and/or intensity of the fluorophore. In the present apparatus, lifetime images are created from a series of images obtained with a gain-modulated image intensifier. The frequency of gain modulation is at the light-modulation frequency (or a harmonic thereof), resulting in homodyne phase-sensitive images. These stationary phase-sensitive images are collected using a slow-scan CCD camera. A series of such images, obtained with various phase shifts of the gain-modulation signal, is used to determine the phase angle and/or modulation of the emission at each pixel, which is in essence the phase or modulation lifetime image. An advantage of this method is that pixel-to-pixel scanning is not required to obtain the images, as the information from all pixels is obtained at the same time. The method has been experimentally verified by creating lifetime images of standard fluorophores with known lifetimes, ranging from 1 to 10 ns. As an example of biochemical imaging we created life-time images of Yt-base when quenched by acrylamide, as a model for a fluorophore in distinct environments that affect its decay time. Additionally, we describe a faster imaging procedure that allows images in which a specific decay time is suppressed to be calculated, allowing rapid visualization of unique features and/or regions with distinct decay times. The concepts and methodologies of fluorescence lifetime imaging (FLIM) have numerous potential applications in the biosciences. Fluorescence lifetimes are known to be sensitive to numerous chemical and physical factors such as pH, oxygen, temperature, cations, polarity, and binding to macromolecules. Hence the FLIM method allows chemical or physical imaging of macroscopic and microscopic samples.

Algorithms↗

Fluorescence lifetime imaging of free and protein-bound NADH.

We introduce a methodology, fluorescence lifetime imaging (FLIM), in which the contrast depends on the fluorescence lifetime at each point in a two-dimensional image and not on the local concentration and/or intensity of the fluorophore. We used FLIM to create lifetime images of NADH when free in solution and when bound to malate dehydrogenase. This represents a challenging case for lifetime imaging because the NADH decay times are just 0.4 and 1.0 ns in the free and bound states, respectively. In the present apparatus, lifetime images are created from a series of phase-sensitive images obtained with a gain-modulated image intensifier and recorded with a charge-coupled device (CCD) camera. The intensifier gain is modulated at the light-modulation frequency or a harmonic thereof. A series of stationary phase-sensitive images each obtained with various phase shifts of the gain-modulation signal, is used to determine the phase angle or modulation of the emission at each pixel, which is in essence the lifetime image. We also describe am imaging procedure that allows specific decay times to be suppressed, allowing in this case suppression of the emission from either free or bound NADH. Since the fluorescence lifetimes of probes are known to be sensitive to numerous chemical and physical factors such as pH, oxygen, temperature, cations, polarity, and binding to macromolecules, this method allows imaging of the chemical or property of interest in macroscopic and microscopic samples. The concept of FLIM appears to have numerous potential applications in the biosciences.

In Vitro Techniques↗

Electroluminescent lamp-based phase fluorometer and oxygen sensor.

We have tested 454-nm violet-emitting solid state electroluminescent lamps (ELLs) as inexpensive intensity-modulated excitation light sources for phase fluorometric oxygen sensors. Compared with blue-emitting silicon carbide LEDs, planar surface ELLs can be produced in various shapes and in large sizes. Accordingly, the overall optical output power emitted by ELLs is much higher than that of blue LEDs. By arranging a large-size ELL close to a large-size fluorescent chemical sensor, we obtained a large number of fluorescence photons allowing for the use of a pin photodiode instead of a photomultiplier tube as the detector. For a sinusoidal driving voltage at a frequency f, the ELL output light is modulated at 2f and at harmonics of 2f. Because of this nonlinear modulation characteristic, we used a square wave driving signal, resulting in a pulsed light output at a repetition rate twice the square wave frequency. The shortest light pulses obtained had a FWHM close to about 1 microsecond. This means that the violet ELLs used in our tests provide modulation frequencies at twice the square wave driving frequency and at all harmonics thereof up to about 1 MHz. This would allow the use of fluorescent chemical sensors with decay times as short as 30 ns, assuming that a phase shift of 10 degrees is adequate for the application. Due to the high ELL driving voltage, effective shielding is required to avoid electromagnetic interference between the modulated light source and the photodetector. Depending on the driving frequency and voltage applied, the ELLs showed a decrease in the optical output power to 50 or even 10% during the first 100 h of operation.

Biosensing Techniques↗

Fluorescence lifetime imaging of calcium using Quin-2.

We describe the use of a new imaging technology, fluorescence lifetime imaging (FLIM), for the imaging of the calcium concentrations based on the fluorescence lifetime of a calcium indicator. The fluorescence lifetime of Quin-2 is shown to be highly sensitive to [Ca2+]. We create two-dimensional lifetime images using the phase shift and modulation of the Quin-2 in response to intensity-modulated light. The two-dimensional phase and modulation values are obtained using a gain-modulated image intensifier and a slow-scan CCD camera. The lifetime values in the 2D image were verified using standard frequency-domain measurements. Importantly, the FLIM method does not require the probe to display shifts in the excitation or emission spectra, which may allow Ca2+ imaging using other Ca2+ probes not in current widespread use due to the lack of spectral shifts. Fluorescence lifetime imaging can be superior to stationary (steady-state) imaging because lifetimes are independent of the local probe concentration and/or intensity, and should thus be widely applicable to chemical imaging using fluorescence microscopy.

Aminoquinolines↗

Tryptophan fluorescence intensity and anisotropy decays of human serum albumin resulting from one-photon and two-photon excitation.

We measured the emission spectra, intensity decays and anisotropy decays of the single tryptophan residue of human serum albumin (HSA) resulting from one-photon (295-298 nm) and two-photon (590-596) excitation. The emission spectra and intensity decays were independent of the mode of excitation. The anisotropy decays were superficially similar for one- and two-photon excitation. However, upon consideration of the different orientation photoselection for one- and two-photon excitation, the anisotropy data reveal different angles between the absorption and emission oscillators for one-photon and two-photon excitation. This result suggests different relative one-photon and two-photon cross-sections for the 1La and 1Lb transitions of the indole residue. This first report of the time-resolved anisotropy decay of a protein resulting from two-photon excitation suggests that such measurement will yield insights into the complex photophysical properties of tryptophan residues in proteins.

Fluorescence Polarization↗

Resolution of end-to-end diffusion coefficients and distance distributions of flexible molecules using fluorescent donor-acceptor and donor-quencher pairs.

We used time-dependent fluorescence energy transfer, time-dependent collisional quenching, and global analysis of the data resulting from these through-space and contact interactions to recover the end-to-end distance distributions and diffusion coefficients of flexible fluorescent molecules. The fluorescence decays of covalently linked tryptamine-acceptor and tryptamine-quencher pairs were measured by the frequency-domain method. These data were fit using numerical solutions of the differential equation, which predicts the time- and distance-dependent population of the excited state donors in the presence of energy transfer or collisional quenching, followed by transformation to the frequency domain for nonlinear least-squares comparison with the experimental data. We found that the energy transfer data for the donor-acceptor pair alone were adequate to recover the starting distribution and the end-to-end diffusion coefficient; however, the resolution is dramatically improved by the use of both the through-space and contact interactions.

Mathematics↗