PubMed Health⌕ Search

Biomedical subjects

J R Montiès

Publications and source records attributed to J R Montiès.

At least 19 recordsLinked to original sources

Late results of double-valve replacement with biologic or mechanical prostheses.

BACKGROUND: We previously showed that the risk of reoperation for structural degeneration of bioprostheses was higher in cases involving patients older than 65 years (p = 0.003) and double-valve replacement (p = 0.02). The purpose of this study was to compare late outcome of mitral-aortic valve replacement using bioprostheses or mechanical valves. METHODS: The bioprosthesis group included all mainland France residents (n = 48) between 55 and 65 years old operated on between 1980 and 1995 for mitral-aortic valve replacement using bioprostheses. The mechanical valve group was obtained by matching each of these patients with a patient operated on using mechanical valves at approximately the same time during the study. RESULTS: In the bioprosthesis group, 10-year survival was 45%+/-8% versus 62%+/-7% in the mechanical valve group (not significant). The linearized reoperation rate was 6.8 per patient-year versus 1.1 per patient-year (p = 0.001), and the linearized reoperative mortality rate was 1.8 per patient-year and 0.7 per patient-year (not significant), respectively. CONCLUSIONS: The reoperative mortality risk after mitral-aortic valve replacement using two bioprostheses does not significantly decrease overall survival after age 65 years.

Aged↗

Centrifugal pumps and heparin-coated circuits in surgical treatment of giant cerebral aneurysms.

Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive series of 8 patients were operated on for giant cerebral aneurysms with the combined use of deep hypothermia. The protocol included careful preoperative cardiovascular assessment, perfect intraoperative synergy between neurosurgical and cardiac teams, minimally invasive peripheral vascular access including two femoral vein (21 F) and single arterial (17 F) femoral cannulation, use of total Carmeda coating on BioMedicus pumps in closed circuits, and reduced heparinization without Protamine reversal. All cerebral aneurysms were successfully treated through deep hypothermia (15-18 degrees C) as assessed by intraoperative fluoroscopic controls and Doppler vascular assessment. Mean circulatory support time was 174.2 +/- 29.6 min. Circulatory arrest period was 20 +/- 12 min. All patients survived and were extubated within 48 h. No major deficit was observed clinically or on postoperative CT scan. No hemorrhagic complications occurred (mean transfusions was 2.2 blood units). This work supports an extensive use of heparin-coated surfaces for complex circulatory assist techniques, either for cardiac or extra cardiac complex procedures.

Adolescent↗

Clinical evaluation of heparin-coated circuits for routine coronary artery bypass grafting surgery: a prospective randomized study.

The aim of this study was to demonstrate the clinical and biological benefits of heparin-coated circuits in routine coronary artery bypass grafting (CABG). A prospective, randomized study was conducted in 80 patients undergoing routine CABG. Patients were randomized to either noncoated circuits (Group 1) or heparin-coated circuits (Group 2). A complete clinical evaluation was performed preoperatively at Days 0, 1, 2, and 3 and at discharge day and combined with extensive laboratory tests for hemostasis and inflammatory response. This study did not prove any major statistically significant clinical benefit of heparin-coated circuits in low risk patients. Postoperative bleeding, significantly less in the heparin-coated group, did not decrease significantly the number of transfused patients. Biological values were not changed significantly except for factor II and monocytes, which were higher in Group 2. Heparin-coated circuits offer minimal clinical and biological benefits for routine CABG surgery. However, they may prove beneficial for complex procedures or at-risk patients.

Aged↗

Study of left ventricular bypass using Wankel type semipulsatile blood pump.

The influence of the Wankel type semipulsatile left ventricular assistance on hemodynamics was investigated with a computer simulation and an animal experiment. A simulation circuit was constructed to express the circulatory system. A current source was added to create a semipulsatile blood pump. The left and right ventricles were replaced by variable compliances. Left heart failure was simulated by decreasing the amount of compliance change of the left ventricle. Under the condition of heart failure when semipulsatile assist flow increased, the mean aortic pressure (AoP), tension time index (TTI), and diastolic pressure time index (DPTI) increased, and the cardiac output, pulse pressure (PP), and pulsatility indicator (PI) decreased. In an animal experiment, a Wankel type blood pump was used in a calf. With the increase of the assist flow, AoP curves became less pulsatile, and PP and PI decreased in accordance, which was predicted by the numerical simulation.

Animals↗

Cora rotary pump for implantable left ventricular assist device: biomaterial aspects.

Our group is developing a left ventricular assist device based on the principle of the Maillard-Wankel rotative compressor: it is a rotary, not centrifugal, pump that produces a pulsatile flow. Stringent requirements have been defined for construction materials. They must be light, yet sufficiently hard and rigid, and able to be machined with high precision. The friction coefficient must be low and the wear resistance high. The materials must be chemically inert and not deformable. Also, the materials must be biocompatible, and the blood contacting surface must be hemocompatible. We assessed the materials in terms of physiochemistry, mechanics, and tribology to select the best for hemocompatibility (determined by studies of protein adsorption; platelet, leukocyte, and red cell retention; and hemolysis, among other measurements) and biocompatibility (determined by measurement of complement activation and toxicity, among other criteria). Of the materials tested, for short- and middle-term assistance, we chose titanium alloy (Ti6Al4V) and alumina ceramic (Al2O3) and for long-term and permanent use, composite materials (TiN coating on graphite). We saw that the polishing process of the substrate must be improved. For the future, the best coating material would be diamond-like carbon (DLC) or crystalline diamond coating.

Adsorption↗

Value of Doppler echocardiography in the detection of low-grade rejections after cardiac transplantation.

Modifications of the diastolic parameters pressure half-time (PHT) and isovolumic relaxation time (IVRT), recorded using cardiac Doppler echocardiography (CDE), were studied in 23 heart transplant recipients and compared to the results of 345 endomyocardial biopsies (EMB) performed on the same day. Two different protocols, analyzing respectively (1) a decrease of 20% or more in IVRT and/or PHT with respect to the mean and (2) a decrease of 20% or more in IVRT and/ or PHT with respect to its preceding value, were used to evaluate the efficiency of CDE in diagnosing mild and moderate rejections. When a mild rejection was detected by EMB, a statistically significant decrease was found in the average CDE parameter values of the patient population. However, these variations were weak and did not differ from the spontaneous variations observed in each patient in the absence of rejection. Thus, it is not surprising that the sensitivity of CDE in the detection of mild rejections was very low (45%) using the most sensitive protocol (variations of the parameters from their preceding value). We conclude that CDE alone does not seem to be sufficient to perform the noninvasive diagnosis of low-grade rejections and must be complemented by other noninvasive methods.

Adult↗

Experimental use of a semipulsatile rotary blood pump for cardiopulmonary bypass.

We tested our valveless pulsatile rotary blood pump (CORA) extensively in animals, but only as a temporary implantable left ventricular assist device. To expand the scope of future clinical applications, we recently undertook experiments to assess the feasibility of our pump for use in a standard cardiopulmonary bypass circuit. We conducted 4 experiments in adult sheep (body weight, 40 kg): 2 with CORA and 2 with the BioMedicus pump (BP) for comparison. In all experiments, a currently used extracorporeal circuit with reservoir, filter, and membrane oxygenator (Sorin monolith) was installed, and open chest extracorporeal circulation (ECC) was performed for 6 h. Hemodynamic performance and hemolysis were evaluated. CORA provided semipulsatile systemic flow at a level comparable to that of the BP. Free plasma hemoglobin levels were slightly higher with CORA, but the decrease in platelet count was the same for both devices. There was no significant difference in the extent of blood trauma. We conclude that CORA could be successfully used for ECC with an oxygenator. Negative pressure can be prevented by our specially designed control system.

Animals↗

Clinical situations and results of cardiopulmonary support by peripheral access for resuscitation and recovery.

Use of cardiopulmonary support (CPS) by peripheral access with a membrane oxygenator has made considerable progress as a result of the development of centrifugal pumps, percutaneous cannulation, and preheparinized circuits. We have used CPS for resuscitation in 3 cases, for recovery after cardiotomy in 6 cases (myocardial insufficiency, 4; pulmonary arterial hypertension, 1; respiratory insufficiency, 1), and after heart transplantation in 1 case. Of these 10 patients, 3 died during CPS, 5 were successfully weaned, and 2 underwent heart transplantation. Use of CPS is expanding for emergency cardiac assistance. Installation is simple and rapid. It allows recovery of organs pending more invasive and costly techniques.

Adult↗

[Repeated heart valve replacements: prognosis and results].

In order to determine the prognosis of reoperation for valvular replacement, we reviewed the results of a consecutive series of 124 patients operated in the department between 1974 and 1992 (163 multi redo operations). There were 69 women and 55 men, with a mean age 48 years; 77% of the patients were in functional class III or IV. Operations were performed as an emergency in 30% of cases. Endocarditis was found in 24% of cases and was an important risk factor in this content. The main indications for reoperation were periprosthetic leakage in 28.8% of cases and failure of bioprostheses in 23.7%. The valvular replacement was simple in 61%, double in 32% and triple in 7% of cases. An associated procedure was necessary in 27% of cases. Mechanical devices were implanted in 62.3% of cases. Peroperative mortality was 3% and hospital mortality, mainly from cardiac causes, was 21.7% for the second, 20% for the third and 55.6% for the fourth reoperations. Operative mortality was dependent on the number or reoperations, functional class, emergency surgery, duration of bypass and cross-clamping time. Four per cent of patients were lost to follow-up and 30 patients died secondarily. The actuarial survival rate was 52% at 5 years and 33% at 10 years, actuarial survival rate without valvular complication was 41% at 5 years and 19% at 10 years but the functional results remained good with over 90% of patients in functional class I or II at the end of follow-up.

Adolescent↗

Development of the Marseilles pulsatile rotary blood pump for permanent implantable left ventricular assistance.

We have developed a low-speed, double-lobed hypocycloidal pump that furnishes a pulsatile flow without valves. The pump is coupled to a specially designed electric motor. The motor/pump unit is totally implantable and has been extensively tested in vitro and in vivo in animals. Because this pump is volumetric, it is necessary to control speed precisely to avoid overpumping. Our control system, which is based on analysis of the motor current wave form, can detect and prevent negative pressures before they occur. The physical properties and hemocompatibility of several construction materials have been studied to determine their suitability for clinical use. These materials include a graphite substrate, titanium nitrate surface coating, boric carbon, and amorphous diamond. The pumps currently being tested are made of titanium, but clinical versions will be made of composite materials selected from this preliminary study. In vivo testing of this pump confirmed its good hemodynamic performance, low hemolysis rate, and biocompatibility (i.e., low heat, noise, and vibration levels). Animal experiments were terminated after 15 days because of mechanical failure related to the accumulation of blood components on moving parts. A new pump in which the mechanism is completely sealed from the blood flow has been designed and will soon be tested. If this sealed design is effective, the pump should be ready for use as a permanent implantable ventricular assistance device.

Animals↗

Early detection of heart transplant rejection using cardiac echography combined with the assay of glycosylated residues in plasma by proton NMR spectroscopy.

Early diagnosis of acute cardiac graft rejection by non-invasive methods is required for medical, organizational, psychological and economic reasons. We have monitored 18 heart recipients over a period of 2.5 years using endomyocardial biopsies (EMB), cardiac Doppler-echography (CDE) and proton NMR spectroscopy assay of plasma glycosylated residues. Diastolic parameters of CDE and assay of the glycosylated residues by NMR spectroscopy respectively detect 42 and 45% of the acute low grade (mild or moderate) histological rejections. The combination of the two methods allows the detection of 65% of rejections. The strategy combining plasma NMR spectroscopy and echography is pertinent to the non-invasive detection of acute cardiac rejections with low histological grade.

Adult↗

[Value of magnetic resonance imaging in 2 cases of annular constriction of the ventricles].

Chronic pericarditis can take the form of localised annular bands constricting the atrioventricular grooves, the pulmonary infundibulum and, rarely, the atria. The authors report two cases of pericardial bands surrounding the ventricles and involving the atrioventricular groove resulting in a biloculation of the left ventricle. One case was complicated by adiastole and one by mitral regurgitation due to involvement of the posterior mitral leaflet. Magnetic resonance imaging gave precise definition of these bands and of their extension into the myocardium. This investigation was a valuable complement before surgery of the localised constriction.

Calcinosis↗

[Jet intravenous injection of erythromycin lactobionate. A possible cause of the occurrence of crisis in torsade de pointe].

The authors report one case of torsade de pointe which occurred immediately after fast intravenous injection of a 1-gram dose of erythromycin lactobionate in a female patient who had undergone surgical replacement of the mitral and triscuspid valves 24 hours before. The responsibility of erythromycin was strongly suggested by the clinical data (syncope), electrocardiographic findings (electrocardiogram typical of torsade de pointe, slow rhythm and lengthened QT interval in the basal ECG) and the chronology of the sequence of intravenous injection of the antibiotic and the rhythm disorder. A literature search revealed six similar cases. Its seems that the arrythmogenic property of this drug is related to abnormally elevated serum levels following rapid administration.

Erythromycin↗