PubMed Health⌕ Search

Biomedical subjects

J R Varvel

Publications and source records attributed to J R Varvel.

11 recordsLinked to original sources

Pharmacokinetics of inhaled liposome-encapsulated fentanyl.

BACKGROUND: Pulmonary administration of fentanyl solution can provide satisfactory but brief postoperative pain relief. Liposomes are microscopic phospholipid vesicles that can entrap drug molecules. Liposomal delivery of fentanyl has the potential to control the uptake of fentanyl by the lungs and thus provide sustained drug release. To demonstrate that inhalation of a mixture of free and liposome-encapsulated fentanyl can provide a rapid increase and sustained plasma fentanyl concentrations (CfenS), this study determined the pharmacokinetic profiles after the inhalation of free and liposome-encapsulated fentanyl in healthy volunteers. METHODS: After obtaining institutional approval and informed consent, ten healthy volunteers (five men, five women) were studied. Each subject received 200 micrograms intravenous fentanyl and inhaled 2,000 micrograms of free (50%) and liposome-encapsulated fentanyl (50%) on separate occasions. Frequent venous blood samples were collected, and CfenS were determined by radioimmunoassay. The pharmacokinetics and absorption characteristics of the inhaled mixture of free and liposome-encapsulated fentanyl were determined using moment analysis and least-squares numeric deconvolution. RESULTS: The mean (+/- SD) volume of distribution at steady-state and clearance of fentanyl after the intravenous administration were comparable to previous studies: 435 +/- 1821 and 0.584 +/- 0.209 l.min-1, respectively. The mean (+/- SD) peak Cfen was significantly greater for the intravenous administration compared to the aerosol mixture of free and liposome-encapsulated fentanyl (4.67 +/- 1.87 vs. 1.15 +/- 0.36 ng.ml-1). However, CfenS at 8 and 24 h after aerosol administration were greater compared to intravenous (0.25 +/- 0.14 and 0.12 +/- 0.16 ng.ml-1 for aerosol versus 0.16 +/- 0.10 and 0.05 +/- 0.06 ng.ml-1 for intravenous). The peak absorption rate, time to peak absorption, and bioavailability after inhalation were 7.02 (+/- 2.34) micrograms.min, -1(16) (+/- 8.0) min, and 0.12 (+/- 0.11), respectively. CONCLUSIONS: The data suggest that this analgesic method offers a simple and noninvasive route of administration with a rapid increase of Cfen and a prolonged therapeutic fentanyl concentration. Future studies are required to determine the optimal liposome composition that would produce a sustained stable Cfen within analgesic therapeutic concentrations.

Adult↗

Application of semilinear canonical correlation to the measurement of opioid drug effect.

To examine the relationship between the electroencephalograph (EEG) and plasma opioid concentration, one would like to collapse the high-dimensional EEG signal into a univariate quantity. Such a simplification of the EEG is desirable because a univariate quantity can be modeled using standard nonlinear regression techniques, and because most of the information in the EEG is redundant or unrelated to drug concentration. In previous studies of the EEG response to opioids, the manner in which a univariate component was extracted from the EEG was ad hoc. In this paper, this extraction was performed optimally using a new statistical technique, semilinear canonical correlation. Data from 15 patients who received an intravenous infusion of the semisynthetic opioid alfentanil were analyzed. The components of the EEG that were nearly maximally correlated with plasma drug concentration were found, based on a standard pharmacokinetic-pharmacodynamic model. Two new EEG components were produced from the powers in the frequency spectrum of the EEG: a weighted sum of the logarithms of the powers, and a weighted sum of the powers expressed as percentages of the total power. These components both had a median R2 of 0.84, compared to median R2s ranging from 0.37 to 0.83 for five commonly used ad hoc EEG components. The new components also had less variability in R2 between subjects.

Adult↗

Measuring the predictive performance of computer-controlled infusion pumps.

Current measures of the performance of computer-controlled infusion pumps (CCIPs) are poorly defined, of little use to the clinician using the CCIP, and pharmacostatistically incorrect. We propose four measures be used to quantitate the performance of CCIPs: median absolute performance error (MDAPE), median performance error (MDPE), divergence, and wobble. These measures offer several significant advantages over previous measures. First, their definitions are based on the performance error as a fraction of the predicted (rather than measured) drug concentration, making the measures much more useful to the clinician. Second, the measures are defined in a way that addresses the pharmacostatistical issue of appropriate estimation of population parameters. Finally, the measure of inaccuracy, MDAPE, is defined in a way that is consistent with iteratively reweighted least squares nonlinear regression, a commonly used method of estimating pharmacokinetic parameters. These measures make it possible to quantitate the overall performance of a CCIP or to compare the predictive performance of CCIPs which differ in either general approach (e.g., compartmental model driven vs. plasma efflux approach), pump mechanics, software algorithms, or pharmacokinetic parameter sets.

Adult↗

Thiopental pharmacodynamics. II. Quantitation of clinical and electroencephalographic depth of anesthesia.

This study examined the relationship among pseudo-steady-state (constant) serum thiopental concentrations, clinical anesthetic depth as assessed by several perioperative stimuli, and the electroencephalogram (EEG). Twenty-six ASA physical status 1 or 2 patients participated in the study. Two constant serum thiopental concentrations were maintained in each patient using a computer-controlled infusion pump. The first randomly assigned target serum concentration of 10-30 micrograms/ml was maintained for 5 min to allow serum:brain equilibration. Then the following stimuli were applied at 1-min intervals: verbal command, tetanic nerve stimulation, trapezius muscle squeeze, and laryngoscopy. A second, higher, randomly assigned target serum concentration of 40-90 micrograms/ml was then achieved and maintained by the computer-controlled infusion pump. The previously described stimuli were reapplied, after which laryngoscopy and intubation was performed. A positive response was recorded if purposeful extremity movement or coughing was observed. Using the quantal movement or cough response and the measured constant serum thiopental concentration, the probability of no movement to each stimulus was characterized using logistic regression. The serum thiopental concentrations that produced a 50% probability of no movement response for the clinical stimuli were as follows: 15.6 micrograms/ml for verbal command, 30.3 micrograms/ml for tetanic nerve stimulation, 39.8 micrograms/ml for trapezius muscle squeeze, 50.7 micrograms/ml for laryngoscopy, and 78.8 micrograms/ml for laryngoscopy followed by intubation. The EEG was analyzed using aperiodic waveform analysis to derive the number of waves per second. A biphasic relationship between constant serum thiopental concentration and the EEG number of waves per second was observed. Loss of responsiveness to verbal stimulation occurred when the EEG was activated at 15-18 waves/s.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Pharmacokinetics, pharmacodynamics, and rational opioid selection.

Fentanyl, alfentanil, and sufentanil have important pharmacokinetic and pharmacodynamic differences. Selecting one of these opioid analgesics as an adjunct to general anesthesia requires appreciation of the relationship between the pharmacokinetic and pharmacodynamic characteristics of these drugs and the onset of and recovery from drug effect. Using a pharmacokinetic-pharmacodynamic model, the authors simulated the decrease in plasma fentanyl, alfentanil, and sufentanil concentration after intravenous administration by either bolus injection, brief infusion, or prolonged infusion. The percentage change in concentration, rather than absolute concentration, was simulated to permit comparison of the relative opioid concentration independently of drug potency. These computer simulations quantified the relationship between infusion duration and the time required for recovery after termination of the infusion. The analysis suggests that alfentanil is best used for operations longer than 6-8 h when a rapid decrease in effect site (i.e., biophase) opioid concentration is desired after discontinuation of the infusion. Alfentanil may also be the most appropriate drug to provide a transient peak effect after a single bolus. Although sufentanil has longer distribution and elimination half-lives than alfentanil, recovery from sufentanil infusions may be more rapid than recovery from alfentanil infusions for operations shorter than 6-8 h. These computer simulations demonstrate that simply comparing pharmacokinetic parameters (e.g., half-lives) of different drugs will not predict the relative rates of decrease in effect site concentrations after either an intravenous bolus or a continuous infusion.

Alfentanil↗

Absorption and bioavailability of oral transmucosal fentanyl citrate.

Oral transmucosal fentanyl citrate (OTFC) is a novel, noninvasive dosage form of fentanyl used to provide children and adults with sedation, anxiolysis, and analgesia. In order to determine the bioavailability and absorption of fentanyl from OTFC, 12 volunteers were given intravenous fentanyl citrate or OTFC 15 micrograms/kg on each of two occasions. On a third occasion, the authors assessed oral administration (gastrointestinal absorption) by giving eight of the same volunteers the same dose of a solution of fentanyl citrate to swallow. In each study, arterial blood samples were taken over 24 h for analysis of plasma fentanyl. After intravenous (iv) administration of fentanyl, clearance (mean +/- standard deviation) was 0.67 +/- 0.15 l/min; volume of distribution at steady state was 287 +/- 79 l; and the terminal elimination half-life was 425 +/- 102 min. Peak plasma concentrations of fentanyl were higher (3.0 +/- 1.0 vs. 1.6 +/- 0.6 ng/ml, P = 0.01) and occurred sooner (22 +/- 2.5 vs. 101 +/- 48.8 min, P = 0.003) after OTFC than after oral solution administration. Plasma concentrations of fentanyl after OTFC decreased rapidly, to less than 1.0 ng/ml within 75-135 min after the beginning of administration. Peak absorption rate was greater (11.1 +/- 4.3 vs. 3.6 +/- 2.1 micrograms/min, P = 0.004) and occurred much sooner after OTFC than after oral solution administration (19 +/- 2.6 vs. 87.5 +/- 38.1 min, P = 0.001). Systemic bioavailability was greater after OTFC administration than after the oral solution (0.52 +/- 0.1 vs. 0.32 +/- 0.1, P = 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Oral↗

The prospective use of population pharmacokinetics in a computer-driven infusion system for alfentanil.

Maitre et al. recently evaluated the accuracy of a set of previously determined population pharmacokinetic parameters for the opioid alfentanil using data from an earlier study in which the drug had been administered using a computer-controlled infusion pump (CCIP). The present study evaluated the accuracy of these same parameters in a CCIP prospectively in two groups of clinically dissimilar patients: 29 healthy female day surgery patients and 11 relatively older and less healthy male inpatients. In addition, another set of pharmacokinetic parameters, previously determined by Scott et al. in the CCIP in 11 male inpatients was also evaluated. The bias and inaccuracy were assessed by the median performance error (MDPE) and the median absolute performance error (MDAPE) in which the performance error was determined as the difference between measured and target serum concentration as a fraction of the target serum concentration. Unlike Maitre et al., the current study found a consistent bias in both populations. The MDPE was +53% and the MDAPE was 53%, with no difference between patient groups. In the 11 patients studied using the Scott et al. pharmacokinetic parameters, the MDPE was +1% and the MDAPE was 17%. The parameters of Scott et al. were further tested by simulating the serum concentrations that would have been achieved had they been used in the CCIP in the first 40 patients; results indicated MDPE of +2% and an MDAPE of 18%. Therefore, reasonably reliable and accurate target serum concentrations of alfentanil can be achieved using the pharmacokinetic parameters of Scott et al. in a CCIP.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Pharmacokinetics of fentanyl administered by computer-controlled infusion pump.

Fentanyl was administered to 21 patients using a computer-controlled infusion pump (CCIP) based on a pharmacokinetic model. Eleven of the patients were dosed according to the pharmacokinetics described by McClain and Hug, and ten of the patients were dosed according to the pharmacokinetics described by Scott and Stanski. The authors measured the difference between the measured arterial fentanyl concentrations and the concentrations predicted by the CCIP for each pharmacokinetic parameter set. The median absolute performance error (MDAPE) in patients dosed according to McClain and Hug's parameters was 61%, and the MDAPE in patients dosed according to Scott and Stanski's parameters was 33%. The population pharmacokinetics in these 21 patients were analyzed using a pooled data technique. The pharmacokinetics of fentanyl in this population showed a smaller central compartment volume and a more rapid initial distribution half-life than previously estimated for fentanyl. The derived pharmacokinetic parameters described these patients well and also predicted the observed fentanyl concentrations from four previously published fentanyl studies with reasonable accuracy. Comparison of the parameters used by the authors with those of McClain and Hug demonstrated that dosing regimens designed from pharmacokinetic models can be fairly accurate at the times sampled in the original study but may not be accurate at time points not sampled in the original research. The authors concluded that although the pharmacokinetics of fentanyl administered by CCIP are the same as the pharmacokinetics of fentanyl administered by a bolus or constant rate infusion, a pharmacokinetic study using a CCIP may be particularly effective at characterizing the most rapid distribution pharmacokinetic parameters, and thus may provide parameters appropriate for subsequent use in a CCIP.

Adult↗

A comparison of parametric with semiparametric analysis of the concentration versus effect relationship of metocurine in dogs and pigs.

We investigated the ability of two pharmacokinetic modeling techniques to estimate the equilibration delay (i.e., hysteresis) between plasma drug concentration and observed drug effect. The data were from 20 animals (15 dogs, 5 pigs) receiving an infusion of metocurine, a neuromuscular blocking drug. An effect compartment model was used to model the hysteresis and characterize the relationship between drug concentration and effect. The effect compartment model requires identification of ke0, the rate constant of drug elimination from the effect compartment. Two methods were used to estimate ke0. The first technique was to fit the plasma metocurine concentration-time curve to a two-compartment pharmacokinetic model and then to use this pharmacokinetic model, along with the neuromuscular blockade vs. time curve to estimate ke0 and the parameters of a pharmacodynamic model (the Hill equation). The second technique was to directly estimate ke0 by a recently described semiparametric technique that does not require either a pharmacokinetic or pharmacodynamic model, although it does assume that drug flux to and from the effect compartment is a first-order process. This semiparametric technique only estimates a single parameter, ke0. The results from the new semiparametric analysis technique were similar to the results from the parametric analysis. In the few animals where the results differed, the semiparametric analysis produced a better description of the data.

Animals↗

Absorption characteristics of transdermally administered fentanyl.

Fentanyl was administered intravenously and transdermally to eight surgical patients to determine the systemic bioavailability and rate of absorption of the transdermally administered drug. Serum fentanyl concentrations reached a plateau approximately 14 h after placement of the transdermal fentanyl delivery system. This plateau was maintained until removal of the system at 24 h. The decline in serum fentanyl concentrations after removal of the transdermal system had a terminal half-life of 17.0 +/- 2.3 h (mean +/- SD), considerably longer than the terminal elimination half-life seen after intravenous administration of fentanyl in the same patients (6.1 +/- 2.0 h). The rate of fentanyl absorption, predicted to be 100 micrograms/h from in vitro data, appeared to be relatively constant during a period starting 4-8 h after placement of the transdermal system until removal of the system at 24 h. The rate of absorption during this period was 91.7 +/- 25.7 micrograms/h. After removal of the transdermal fentanyl delivery system, absorption continued at a declining rate. This indicates that the long terminal half-life of serum fentanyl concentrations after transdermal system removal is due to continued slow absorption of fentanyl, probably from a cutaneous depot of drug at the site of prior transdermal system placement. At the time of removal of the transdermal fentanyl system, 1.07 +/- 0.43 mg of drug remained in this depot. Systemic fentanyl bioavailability was found to be 0.92 +/- 0.33, with no evidence of significant cutaneous metabolism or degradation by the skin's bacterial flora. The transdermal administration of fentanyl produces relatively constant serum fentanyl concentrations for significant periods of time in the postsurgical patient requiring analgesic therapy.

Administration, Cutaneous↗