PubMed Health⌕ Search

Biomedical subjects

J Rantanen

Publications and source records attributed to J Rantanen.

At least 19 recordsLinked to original sources

Development and characterization of aqueous amylose-rich maize starch dispersion for film formation.

Development and characterization of amylose-rich starch dispersion for film forming was performed. The influence of dispersion preparation temperature on amylose-rich maize starch (Hylon VII) film formation, and the physical properties of the films were investigated. The film-forming ability of the dispersions was evaluated with free films plasticized with glycerol and sorbitol, and the films were prepared at an elevated temperature (70 degrees C) by a casting technique. The solid-state and particle properties of dispersions were investigated by means of X-ray diffraction (XRD), Fourier transform near infrared (FT-NIR) spectroscopy and laser diffraction particle size analysis. Free films were characterized with respect to their appearance, by FT-NIR spectroscopy, and by XRD. Mechanical stress-strain properties were also studied. Increasing the temperature of dispersion preparation results in higher crystallinity, thus affecting the film forming ability. Mechanically strong and elastic films can be formed from amylose-rich starch dispersion formed at 40 degrees C. The more crystalline precipitate complex (obtained at 80 degrees C) and the entirely amorphous gel (obtained at 10 degrees C) formed non-continuous and cloudy films. The better film-forming properties of the dispersion formed at 40 degrees C are probably due to the highly amorphous structure and smaller particle size. The study shows the possibility of using ambient tempered amylose-starch dispersion for film forming.

Amylose↗

Acute traumatic extension deficit of the knee.

The purpose of this study was to evaluate the events leading to acute traumatic extension deficit of the knee and the arthroscopic findings in these patients. A total of 78 consecutive patients treated in the Turku university hospital during the years 1994-1996 were included. The mean annual incidence of acute traumatic extension deficits of the knee in our study was 1.1 per 10 000 inhabitants. The single most common (33%) event causing the extension deficit was non-sports related twisting of the knee. Various sports related activities accounted for 42% of the extension deficits, and soccer was the most common sport in this group. In conclusion, acute traumatic extension deficit of the knee is usually a sign of serious intra-articular damage, and the most likely finding (in 82% of the patients in our study) is either a meniscal rupture, an anterior cruciate ligament (ACL) rupture, a patellar dislocation, or a combination of these. The lesions in these knees require prompt evaluation by an orthopaedic surgeon mainly because of the high number of bucket-handle and menisco-capsular insertion ruptures of the menisci, which are possibly suitable for repair.

Acute Disease↗

The long-term results of Lubinus interplanta hemiarthroplasty in 228 acute femoral neck fractures. A retrospective six-year follow-up.

BACKGROUND AND AIMS: We retrospectively studied survival of patients treated with Lubinus interplanta (IP) semiendoprosthesis in acute hip fracture. MATERIALS AND METHODS: The long-term results of Lubinus interplanta (IP) hemiarthroplasty in 228 acute medial fractures of the femoral neck in 222 patients were reviewed. RESULTS AND CONCLUSIONS: The mean age of the patients was 80.3 years. The mean duration of post-operative follow-up was 6.3 years (range 5-8 years). There were 12 reoperations (5.3%), of which 8 were revisions (3.5%). Dislocation rate was 3.5%. Survival was 93% at three years and 88% at six years (Kaplan-Meier-survival analysis). CONCLUSIONS: These results surpass those previously published after Thompson and Moore hemiarthroplasties. The Lubinus prosthesis has a greater CCD (caput,collum, diaphyse) angle and a longer stem compared to Thompson and Moore implants. The need for resection of calcar cortex is also limited. These biomechanical facts may explain the good long-term results of Lubinus hemiarthroplasty.

Aged↗

Acute traumatic hemarthrosis of the knee. Is routine arthroscopic examination necessary? A study of 320 consecutive patients.

BACKGROUND AND AIMS: Distortions and contusions of the knee are common. Fairly often they will result in hemarthrosis. The purpose of this study was to evaluate the findings in patients with acute traumatic hemarthrosis of the knee and based on these findings estimate the necessity of acute arthroscopic examination. MATERIAL AND METHODS: A total of 320 patients were examined arthroscopically between the years 1994 to 96 in the Turku University Hospital. Patients with other than chondral or osteochondral fractures were excluded. RESULTS: The most common arthroscopic findings were rupture of the ACL (45%), dislocation of the patella (23%) and meniscal tear (21%). In only 113 (35%) cases an immediate therapeutic procedure was performed in addition to the arthroscopic examination. CONCLUSIONS: Based on our findings we believe that routine arthroscopic examination is not necessary in patients with acute traumatic hemarthrosis of the knee. In our opinion the patient should be examined and followed by an orthopedic surgeon and if a lesion requiring operative treatment is diagnosed or suspected, an arthroscopic examination should be scheduled. The timing of the procedure should be such that all possible lesions encountered can be treated in the same operation.

Acute Disease↗

Process analysis of fluidized bed granulation.

This study assesses the fluidized bed granulation process for the optimization of a model formulation using in-line near-infrared (NIR) spectroscopy for moisture determination. The granulation process was analyzed using an automated granulator and optimization of the verapamil hydrochloride formulation was performed using a mixture design. The NIR setup with a fixed wavelength detector was applied for moisture measurement. Information from other process measurements, temperature difference between process inlet air and granules (T(diff)), and water content of process air (AH), was also analyzed. The application of in-line NIR provided information related to the amount of water throughout the whole granulation process. This information combined with trend charts of T(diff) and AH enabled the analysis of the different process phases. By this means, we can obtain in-line documentation from all the steps of the processing. The choice of the excipient affected the nature of the solid-water interactions; this resulted in varying process times. NIR moisture measurement combined with temperature and humidity measurements provides a tool for the control of water during fluid bed granulation.

Excipients↗

Novel identification of pseudopolymorphic changes of theophylline during wet granulation using near infrared spectroscopy.

The purpose of this study was to demonstrate the efficiency of near infrared (NIR) spectroscopy in studying the pseudopolymorphic changes and the state of water during the wet granulation process. Anhydrous theophylline was granulated in a planetary mixer using water as granulation liquid. NIR spectra and differential scanning calorimetric (DSC) and wide-angle X-ray scattering (WAXS) patterns of theophylline granules, anhydrous theophylline, and theophylline monohydrate were measured. At a low level of granulation liquid (0.3 mol of water per mole of anhydrous theophylline), water absorption maxima in the NIR region occurred first at around 1475 and 1970 nm. These absorption maxima were identical to those of theophylline monohydrate. At higher levels of granulation liquid (1.3-2.7 mol of water per mole of anhydrous theophylline), the increasing absorption maxima occurred at 1410 and 1905 nm due to OH vibrations of free water molecules. X-ray diffraction patterns confirmed the transformation of anhydrous theophylline to theophylline monohydrate during wet granulation. NIR spectroscopy was able to detect different states of water molecules during the wet granulation process faster and in a more flexible manner than conventional methods.

Calorimetry, Differential Scanning↗

Microcrystalline cellulose-water interaction--a novel approach using thermoporosimetry.

PURPOSE: To study the physical state of water in microcrystalline cellulose (MCC) and in silicified microcrystalline cellulose wet masses and the effect of granulation on different water fractions. METHODS: Thermoporosimetry, together with the solute exclusion technique, was used to measure different water fractions and pore size distributions of wet granules. To understand the effect of granulation on the physical state of water, both ungranulated and granulated wet masses were studied. In addition, dynamic and isothermal step melting procedures were compared. RESULTS: Four distinct fractions of water (nonfreezing, freezing bound, free, and bulk water) could be detected in MCC wet masses. Granulation decreased the volume of bulk water and increased the volume of freezing bound and free water. Consequently, granulated wet masses were able to hold more water inside the particles compared to ungranulated wet masses. Thus, granulation had a similar effect on MCC as beating has on cellulose fibers in the papermaking proces CONCLUSIONS: Thermoporosimetry and solute exclusion increased the understanding of MCC-water interaction and showed how the physical state of water in MCC wet masses changes during granulation.

Algorithms↗

Near infrared reflectance spectroscopy for the fast identification of PVC-based films.

Near infrared (NIR) reflectance spectroscopy was used to develop a non-destructive and rapid qualitative method for the analysis of plastic films used by the pharmaceutical industry for blistering. Three types of films were investigated: 250 microm PVC [poly(vinyl chloride)] films, 250 microm PVC films coated with 40 g m(-2) of PVDC [poly(vinylidene dichloride)] and 250 microm PVC films coated with 5 g m(-2) of TE (Thermoelast) and 90 g m(-2) of PVDC. Three analyses were carried out using different pre-treatment options and a PLS (partial least squares) algorithm. Each analysis was aimed at identifying one type of film and rejecting all types of false sample (different thickness, colour or layer). True and false samples from four plastics manufacturers were included in the calibration sets in order to obtain robust methods that were suitable regardless of the supplier. Specificity was demonstrated by testing validation sets against the methods. The tests showed 0% of type I (false negative identification) and 1% of type II errors (false positive identification) for the PVC method, 13 and 3%, respectively, for the PVC-PVDC method and no error for the PVC-TE-PVDC method. Type II errors, mostly due to the slight sensitivity of the methods to film thickness, are easily corrected by simple thickness measurements. This study demonstrates that NIR spectroscopy is an excellent tool for the identification of PVC-based films. The three methods can be used by the pharmaceutical industry or plastics manufacturers for the quality control of films used in blister packaging.

Drug Packaging↗

Characterization of wet massing behavior of silicified microcrystalline cellulose and alpha-lactose monohydrate using near-infrared spectroscopy.

The purpose of this study was to investigate the energetic state of water in silicified microcrystalline cellulose (SMCC) and alpha-lactose monohydrate wet masses using near-infrared (NIR) spectroscopy. The applicability of NIR spectroscopy to studying pharmaceutical wet masses at a wide moisture range was evaluated in comparison with mixer torque rheometry (MTR). With increasing moisture content changes in the physical properties of the samples resulted in an apparent increase in log (1/R) throughout the whole spectrum. The upward displacement of baseline and the relative height of water bands were greatest with materials that had a poor liquid-retention capacity. In the case of SMCC and 1:1 mixture of SMCC and alpha-lactose monohydrate, the height of the baseline-corrected water bands increased linearly at low moisture contents, thereafter achieving a plateau stage. According to the MTR results, the plateau stage of the band heights indicated a capillary state of liquid saturation. The second derivative spectrum was capable of distinguishing monohydrate, absorbed, and adsorbed water, which overlapped in the absorbance spectrum. When water was absorbed to the internal structure of the material (SMCC), the water bands were first seen at higher wavelengths, then followed by a shift to lower wavelengths. When water was only adsorbed onto the surface of the particles (glass ballotini), the water bands were seen directly in the region of bulk water.

Crystallization↗

The expression of intermediate filament protein nestin as related to vimentin and desmin in regenerating skeletal muscle.

Intermediate filament (IF) proteins show specific spatial and temporal expression during development of skeletal muscle. Nestin, the least known muscle IF, has an important role in neuronal regeneration. Therefore, we analyzed the expression pattern of nestin as related to that of vimentin and desmin during skeletal muscle regeneration. Nestin and vimentin appear at 6 h post-injury in myoblasts, with maximum expression around day 3-5 post-injury. Thereafter, vimentin expression ceases completely, whereas that of nestin is downregulated to remain only in the sarcoplasm next to neuromuscular and myotendinous junctions. Desmin appears at 6-12 h post-injury and becomes the predominant IF in myofibers simultaneously with the appearance of cross-striations. The expression pattern and colocalization of nestin and vimentin, known to form heteropolymers, suggests that they are essential during the early dynamic phase of the myofiber regeneration when migration, fusion, and structural modeling of myogenic cells occurs, whereas desmin is responsible for keeping myofibrils in register in mature myofibers. In conclusion, the expression of nestin is dynamically orchestrated with that of vimentin and desmin during skeletal muscle regeneration and recapitulates that seen during myogenesis, i.e. these IFs have key functional roles in the construction and restoration of skeletal myofibers.

Animals↗

Next generation fluidized bed granulator automation.

A system for fluidized bed granulator automation with in-line multichannel near infrared (NIR) moisture measurement and a unique air flow rate measurement design was assembled, and the information gained was investigated. The multivariate process data collected was analyzed using principal component analysis (PCA). The test materials (theophylline and microcrystalline cellulose) were granulated and the calibration behavior of the multichannel NIR set-up was evaluated against full Fourier Transform (FT) NIR spectra. Accurate and reliable process air flow rate measurement proved critical in controlling the granulation process. The process data describing the state of the process was projected in two dimensions, and the information from various trend charts was outlined simultaneously. The absorbence of test material at correction wavelengths (NIR region) and the nature of material-water interactions affected the detected in-line NIR water signal. This resulted in different calibration models for the test materials. Development of process analytical methods together with new data visualization algorithms creates new tools for in-process control of the fluidized bed granulation.

Calibration↗

Prediction of aqueous solubility for a diverse set of organic compounds based on atom-type electrotopological state indices.

We describe robust methods for estimating the aqueous solubility of a set of 734 organic compounds from different structural classes based on multiple linear regression (MLR) and artificial neural networks (ANN) model. The structures were represented by atom-type electrotopological state (E-state) indices. The squared correlation coefficient and standard deviation for the MLR with 34 structural parameters were r(2) = 0.94 and s = 0.58 for the training set of 675 compounds. For the test set of 21 compounds, the equivalent statistics were r(2)(pred) = 0.80 and s = 0.87, respectively. Neural networks gave a significant improvement using the same set of parameters, and the standard deviations were s = 0.52 for the training set and s = 0.75 for the test set when an artificial neural network with five neurons in the hidden layer was used. The results clearly show that accurate models can be rapidly calculated for the estimation of aqueous solubility for a large and diverse set of organic compounds using easily calculated structural parameters.

Linear Models↗

In-line moisture measurement during granulation with a four-wavelength near infrared sensor: an evaluation of particle size and binder effects.

Factors affecting in-line near infrared (NIR) moisture measurement with a four-wavelength sensor were evaluated (choice of binder used in granulation liquid and the increase in particle size). An entire NIR spectrum is not necessary for the measurement of water, and often the use of only a few NIR wavelengths around the water band enables reliable and high-speed detection of moisture. Glass ballotini and microcrystalline cellulose (MCC) were used as model test materials. The binders studied were poly[1-(2-oxo-1-pyrrolidinyl)ethylene] (PVP) and gelatin. Full off-line NIR spectra of test materials at different levels of binder solutions were measured. The major spectral features for both the binders were bands around 1700 nm (first overtones CH related stretches) and 2200 nm (combination bands). Gelatin also had an NH band around 1500 nm (first overtones of NH stretches) and combination bands at about 2050 nm. Particle size effects were observed as an increase in spectra baseline. All these factors should be considered when choosing NIR wavelengths used for detection of water with a fixed wavelength set-up. A robust calibration model enables the development of in-process control of wet granulation processes.

Calibration↗

Relation between myofibers and connective tissue during muscle injury repair.

The connective tissue framework in skeletal muscle combines the contractile myofibers into a functional unit, in which the contraction of myofibers is transformed into movement via myotendinous junctions (MTJs) at their ends, where myofibers attach to tendons/fascia. The cytoskeletal contractile myofilament apparatus adheres through subsarcolemmal and transmembrane molecules to the surrounding extracellular matrix, with integrin and dystrophin associated chains of molecules being the two main adhesion complexes. In shearing type of muscle injury both myofibers and the connective tissue framework are ruptured and thereby the functional tendon-muscle-tendon units are disrupted. The stumps of the ruptured myofibers are separated and at the same time joined by a connective tissue scar, through which the ends of regenerating myofibers try to pierce, but as the scar becomes more compact the ends attach to the scar by new mini-MTJs. During the early phase ruptured myofibers try to compensate for the lost MTJ attachment by reinforcing their integrin mediated lateral adhesion, which returns to normal low level after formation of the mini-MTJs and at which time complementary increase of dystrophin and associated molecules on lateral sarcolemma takes place. The stumps appear to remain separated by and attached to the interposed scar for many months, possibly for ever, i.e. the original tendon-muscle-tendon units may have become permanently divided into two consecutive units. Remarkably, axon sprouts are able to penetrate through the interposed scar to form new neuromuscular junctions on those abjunctional stumps which were denervated by the rupture.

Athletic Injuries↗

Use of the near-infrared reflectance method for measurement of moisture content during granulation.

The purpose of this study was to demonstrate the use of a near-infrared (NIR) method for in-process control of a placebo formulation. An NIR setup with a multichannel detector was applied in the measurement of water during fluidized bed granulation. The effects of two critical granulation parameters were studied using the central composite design. The present NIR setup with three wavelengths proved applicable for in-line moisture measurement. The 1990 nm signal was used for measurement of water and the 1745 and 2145 nm signals were used to correct the change in spectra baseline during granulation. Variations in inlet air conditions proved to be critical factors, explaining differences in the granule size distributions. Differences in granule moistening and drying rates resulting from varying inlet air conditions could be measured with the NIR setup. The moisture content of granules at the end of the spraying phase explained part of the differences in granule size distributions. The moisture content of granules at the end of the drying phase affected the tableting behavior of granules. The results suggested that direct measurement of granule moisture content facilitates the in-process control of the granulation.

Drug Compounding↗

Results of surgical treatment of unresolved Osgood-Schlatter lesion.

BACKGROUND AND AIMS: We present our experience with surgical treatment of unresolved, painful, late Osgood-Schlatter disease. MATERIAL AND METHODS: In 70 operations performed in 67 patients (in three bilaterally) an ossicle under the distal patellar tendon was removed in 62 cases. In eight cases, excision of the prominent tibial tubercle and/or drilling of the epiphysis was performed. Additional procedures, such as rasping of the uneven anterior tibial surface, excision of inflammed bursa or the devitalized portion of the tendon, were done 21 times. Most patients were athletes or physically active young people. The mean age was 19.6 years. 54 operations were done on males and 16 on females. They had been followed preoperatively for 18 months and after surgery 2.2 years. RESULTS: The final results were excellent or good in 56, moderate in 9, poor in 3 and unknown in 2 cases. CONCLUSIONS: Osgood-Schlatter's disease may leave an ossicle under the distal patellar tendon, a prominent tibial tubercle or an uneven surface of anterior superior tibia. These may lead to pain and disability due to recurrent injuries or athletic exercises. Surgical treatment gives good results in chronic unresolved cases.

Adolescent↗