PubMed Health⌕ Search

Biomedical subjects

J Reisman

Publications and source records attributed to J Reisman.

At least 19 recordsLinked to original sources

Treating asthma with omega-3 fatty acids: where is the evidence? A systematic review.

BACKGROUND: Considerable interest exists in the potential therapeutic value of dietary supplementation with the omega-3 fatty acids. Given the interplay between pro-inflammatory omega-6 fatty acids, and the less pro-inflammatory omega-3 fatty acids, it has been thought that the latter could play a key role in treating or preventing asthma. The purpose was to systematically review the scientific-medical literature in order to identify, appraise, and synthesize the evidence for possible treatment effects of omega-3 fatty acids in asthma. METHODS: Medline, Premedline, Embase, Cochrane Central Register of Controlled Trials, CAB Health, and, Dissertation Abstracts were searched to April 2003. We included randomized controlled trials (RCT's) of subjects of any age that used any foods or extracts containing omega-3 fatty acids as treatment or prevention for asthma. Data included all asthma related outcomes, potential covariates, characteristics of the study, design, population, intervention/exposure, comparators, and co interventions. RESULTS: Ten RCT's were found pertinent to the present report. CONCLUSION: Given the largely inconsistent picture within and across respiratory outcomes, it is impossible to determine whether or not omega-3 fatty acids are an efficacious adjuvant or monotherapy for children or adults. Based on this systematic review we recommend a large randomized controlled study of the effects of high-dose encapsulated omega-3 fatty acids on ventilatory and inflammatory measures of asthma controlling diet and other asthma risk factors. This review was limited because Meta-analysis was considered inappropriate due to missing data; poorly or heterogeneously defined populations, interventions, intervention-comparator combinations, and outcomes. In addition, small sample sizes made it impossible to meaningfully assess the impact on clinical outcomes of co-variables. Last, few significant effects were found.

Adult↗

A comparison of inhaled fluticasone and oral prednisone for children with severe acute asthma.

BACKGROUND: Inhaled corticosteroids are effective in the treatment of children with asthma. It is uncertain how inhaled corticosteroids compare with oral corticosteroids in the management of severe acute disease. METHODS: We performed a double-blind, randomized trial involving 100 children five years of age or older who had severe acute asthma (indicated by a forced expiratory volume in one second [FEV1] that was less than 60 percent of the predicted value) and in whom the results could be evaluated. All were treated with an aggressive bronchodilator regimen and received one dose of either 2 mg of inhaled fluticasone through a metered-dose inhaler with a spacer or 2 mg of oral prednisone per kilogram of body weight. They were assessed hourly for up to four hours. RESULTS: The mean (+/-SD) base-line FEV1 as a percentage of the predicted value was 46.3+/-12.5 in the fluticasone group (51 subjects) and 43.9+/-9.9 in the prednisone group (49 subjects). The FEV1 increased by a mean of 9.4+/-12.5 percentage points in the fluticasone group and by 18.9+/-9.8 percentage points in the prednisone group four hours after therapy (P< 0.001). None of the children in the prednisone group had a reduction in FEV1 as a percentage of the predicted value from base line to four hours, as compared with 25 percent of those in the fluticasone group (P<0.001). Sixteen (31 percent) of the children treated with fluticasone were hospitalized, as compared with five (10 percent) of those treated with prednisone (P=0.01). CONCLUSIONS: Children with severe acute asthma should be treated with oral prednisone and not with inhaled fluticasone or a similar inhaled corticosteroid.

Administration, Inhalation↗

Does ketotifen have a steroid-sparing effect in childhood asthma?

In view of the possible systemic side-effects of inhaled corticosteroids (ICS), a study was performed to determine whether ketotifen (versus placebo) can replace or allow a reduction in the dose of ICS required for the maintenance treatment of childhood asthma. Sixty six children (aged 6-13 yrs) with asthma (confirmed by methacholine challenge), who were maintained on ICS, at a dose of < or = 1 mg.day-1, were selected, and 52 subjects completed the trial. Children on long-term oral steroids or cromoglycate were excluded. After a 4 week baseline period, the children were randomized to receive ketotifen, 2 mg.day-1, or placebo for 32 Weeks. Between weeks 13-20 of the study, the daily dose of steroid was tapered by 25% every second week to the minimum dose tolerated by the patients. For the remainder of the study (Weeks 21-32) the patients continued on this dose (if tolerated). Beta 2-agonists were allowed, as necessary, for symptom relief. During the baseline period, the mean daily ICS dosage was 432 micrograms in the ketotifen group versus 408 micrograms in the placebo group (NS). Among the-patients who completed the study, the average ICS dosage during the final phase of the study (Weeks 21-32) was only 18% of baseline in the ketotifen group versus 35% in the placebo group (NS). Lung function, diurnal variability in peak flow rates and methacholine sensitivity (provocative concentration producing a 20% fall in forced expiratory volume in one second (PC20)) remained unchanged in both groups throughout the study. During the last 12 weeks of the study, the ketotifen-treated patients were symptomatically better controlled. In the present study, ketotifen did not have a greater steroid-sparing effect than placebo.

Administration, Inhalation↗

Maximal expiratory flows generated by rapid chest compression following end-inspiratory occlusion or expiratory clamping in young children.

Partial forced expiratory flow-volume curves obtained by the rapid chest compression technique are being widely used to assess pulmonary function in infants and young children. The aim of this study is to assess whether in this age group flow limitation is achieved with the partial forced expiratory flow-volume curve with rapid chest compression. In eight infants and young children sedated with chloral hydrate, flow-volume curves were obtained by regular rapid chest compression technique, end-inspiratory airway occlusion prior to rapid chest compression, and expiratory clamping prior to rapid chest compression. In each technique, beginning with a cuff pressure of 20 cmH2O, the cuff pressure was increased by 10 cmH2O increments until the compression pressure reached 90 cmH2O. Maximal flow-volume curves were generated by each technique. End-inspiratory occlusion prior to rapid chest compression caused higher flows over the entire phase of expiration than the regular rapid chest compression. This increase could be observed over the entire phase of expiration. Forced expiratory flow at 50% and at 75% of vital capacity (V50 and V75) with regular rapid chest compression were 207 +/- 44 ml.s-1 (mean +/- SD) and 138 +/- 59 ml.sec-1, respectively. When end-inspiratory occlusion preceded rapid chest compression, V50 and V75 increased to 283 +/- 114 and 206 +/- 61 ml.sec-1 respectively, with a mean increase in V50 of 34% and in V75 of 31%. When expiratory clamping preceded the compression, even higher expiratory flows resulted.(ABSTRACT TRUNCATED AT 250 WORDS)

Child, Preschool↗

Efficacy of albuterol administered by nebulizer versus spacer device in children with acute asthma.

The aim of this study was to compare the response to inhaled albuterol after administration by nebulizer with the response after administration by a metered-dose inhaler and spacer device (MDI-spacer) to children with acute asthma. In a double-blind fashion, 33 children (6 to 14 years of age) with forced expiratory volume in 1 second (FEV1) between 20% and 70% of predicted values, and who were seen in the emergency department with acute asthma, were studied. They were treated with aerosolized albuterol or placebo by MDI-spacer, followed immediately by albuterol or placebo administered by nebulizer with oxygen. The dose ratio for albuterol by MDI-spacer versus nebulizer was 1:5. Outcome measures included a clinical score, respiratory rate, arterial oxygen saturation, and FEV1, measured before and 10, 20, and 40 minutes after treatment. With the exception of heart rate (which increased in the nebulizer group and decreased in the MDI-spacer group (p < 0.05), no difference in the rate of improvement of clinical score, respiratory rate, arterial oxygen saturation, or FEV1 was noted during the 40-minute study period between children who received albuterol by nebulizer and those who received it by MDI-spacer. We conclude that spacers and nebulizers are equally effective means of delivering beta 2-agonists to children with acute asthma.

Acute Disease↗

Using a sensory integrative approach to treat self-injurious behavior in an adult with profound mental retardation.

The treatment of self-injurious behavior in adults with mental retardation is a major challenge. A critical review of the literature compares sensory-based treatment studies by behavioral psychologists with sensory integrative treatment studies by occupational therapists. In general, therapists have used direct intervention in concentrated daily sessions. This report includes a single subject study that (a) demonstrates the clinical reasoning involved in the assessment and treatment planning process, (b) documents the efficacy of multiple short treatment sessions spread throughout the day, and (c) presents an alternative model of service provision in which direct care staff provide sensory and adaptive activities under the supervision of an occupational therapist. The use of sensory integration with adults with profound handicaps is presented as a valid application of a theory and treatment that was originally developed from work with higher functioning children with learning disabilities.

Adaptation, Psychological↗

Prediction of mortality in patients with cystic fibrosis.

BACKGROUND: The majority of patients with cystic fibrosis die in early adulthood of lung disease. Lung transplantation is a treatment option for patients with advanced pulmonary disease, although the waiting period for organs may be as long as two years. Our purpose was to determine whether the risk of death due to respiratory failure could be predicted one or two years in advance on the basis of pulmonary function, blood gas levels, and nutritional status. METHODS: The study cohort consisted of 673 patients followed between 1977 and 1989. In each patient, pulmonary function, blood gas levels, nutritional status, and vital status were assessed between 1977 and 1987. Cox proportional-hazards regression analysis was used to compute the relative risk of death within one or two years after particular measurements. The effects of age and sex on mortality were also included in the analysis. RESULTS: One hundred ninety patients (28 percent) died during the study period. Overall, patients with a forced expiratory volume in one second (FEV1) less than 30 percent of the predicted value, a partial pressure of arterial oxygen below 55 mm Hg, or a partial pressure of arterial carbon dioxide above 50 mm Hg had two-year mortality rates above 50 percent. Among the laboratory measurements, the FEV1 was the most significant predictor of mortality, but age and sex were also significant in predicting risk. After adjustment for age and sex, the relative risk of death within two years was 2.0 (95 percent confidence interval, 1.9 to 2.2) for each decrement in the FEV1 of 10 percent below the predicted value. Among patients with the same FEV1, the relative risk of death was 2.0 (95 percent confidence interval, 1.5 to 2.6) in patients 10 years younger than other patients, and 2.2 (1.6 to 3.1) in female patients as compared with male patients. CONCLUSIONS: Patients with cystic fibrosis should be considered candidates for lung transplantation when the FEV1 falls below 30 percent of the predicted value. Female patients and younger patients may need to be considered for transplantation at an earlier stage.

Adolescent↗

Macular capillary hemodynamic changes associated with Raynaud's phenomenon.

BACKGROUND: Raynaud's phenomenon is an episodic, reversible spasm of the digital arterioles. Previous studies have suggested that Raynaud's phenomenon may be associated with alterations in the ocular circulation. The authors used the blue field entoptic simulation technique to study macular retinal capillary hemodynamics in patients with Raynaud's phenomenon. METHODS: Forty-two volunteers participated in the study: 18 with a connective tissue disease and secondary Raynaud's phenomenon, 8 with a connective tissue disease and no Raynaud's phenomenon, and 16 healthy volunteers. The mean of three blue field entoptic density and velocity measurements was determined before as well as during and 10 minutes after the immersion of one hand in ice water. RESULTS: Patients with severe Raynaud's phenomenon demonstrated a statistically significant 30% decrease in retinal capillary flow during immersion of a hand in ice water (P less than 0.05), which remained 17% reduced (P less than 0.05) for at least 10 minutes after removal. The decrease in capillary flow was not observed in control individuals or in individuals with connective tissue disease who demonstrated minimal or no Raynaud's phenomenon. CONCLUSION: The prolonged reduction in retinal capillary flow observed in subjects with Raynaud's phenomenon is probably caused by retinal arteriolar vasoconstriction and is similar to concurrent arteriolar vasoconstriction reported in other systemic vascular beds. In the retina, the recurrent ischemic episodes may result in dysfunction or injury.

Adult↗

Binding of nonmucoid Pseudomonas aeruginosa to normal human intestinal mucin and respiratory mucin from patients with cystic fibrosis.

Lung infections due to Pseudomonas aeruginosa and Pseudomonas cepacia are common in patients with cystic fibrosis. Initial colonization is due to nonmucoid P. aeruginosa, while later mucoid variants emerge and are associated with chronic infection. P. cepacia colonization tends to be more prevalent in older patients. The present study was conducted to discover whether highly purified mucins (from cystic fibrosis sputum and control intestinal secretions) exhibited specific binding of nonmucoid P. aeruginosa. In vitro solid phase microtiter binding assays (with or without a blocking agent) as well as solution phase assays were conducted. Bacteria bound to both mucins via bacterial pili, but no differences in binding capacity were noted between the mucins. Unlike P. cepacia (described in the accompanying manuscript) there was also no preferential binding of P. aeruginosa to mucins versus bovine serum albumin, casein, gelatin, or a host of structurally unrelated proteins and glycoproteins. Carbohydrate hapten inhibition studies did not suggest the existence of specific mucin carbohydrate receptors for P. aeruginosa. In solid phase assays a low concentration (0.05 M) of tetramethylurea abolished P. aeruginosa bacterial binding to both mucins as well as to BSA, whereas in solution phase assays mucin binding to bacteria was not completely disrupted by tetramethylurea. Specific monoclonal antipilus antibodies did not inhibit binding to a greater extent than did Fab fragments of normal mouse IgG. Binding of strains PAO1 and PAK (and isolated PAK pili) to buccal epithelial cells was not influenced by the presence of mucin in binding assay mixtures. Our findings do not support the widely held notion that specific mucin receptors are responsible for the attachment of P. aeruginosa pili, nor do they support the idea that there is a competitive interference by mucins of bacterial binding to respiratory cells. In patients with cystic fibrosis, it would seem unlikely therefore that initial colonization of the lungs by P. aeruginosa is due to a 'selective tropism' of these bacteria for respiratory mucin.

Bacterial Adhesion↗

Performance of the Reflotron in Massachusetts' Model System for Blood Cholesterol Screening Program.

The precision, accuracy, and durability of the Reflotron were evaluated by the Massachusetts Model Systems for Blood Cholesterol Screening Program. Screenings were conducted in diverse community settings over 16 months. Fingerstick samples from 10,428 individuals were tested. None of the four analyzers met the 1992 standards for precision, although two met the 1992 standards for accuracy. More than 40% of Reflotron values differed from the reference laboratory values by upwards of 5%. More than 16% of individuals were misclassified in terms of their risk category. All four instruments malfunctioned during the project.

Bias↗

Wheezing in infants with cystic fibrosis: clinical course, pulmonary function, and survival analysis.

Wheezing is a common finding in infants with cystic fibrosis (CF). This study was undertaken to determine the prevalence of wheezing in infants with CF and to compare the clinical outcome of those who wheezed in infancy with that of those who did not. The study cohort included 229 CF patients born between 1965 and 1979 with CF diagnosed before 2 years of age. Fifty-seven (25%) had physician-documented wheezing during the first 2 years of life. Wheezing had resolved by the age of 2 years in 50% of the patients and by the age of 4 years in 75%. Although wheezing seemed to be linked to a family history of allergy and asthma, the frequency of the delta F508 mutation was similar to that of the non-wheezers. There was no significant difference in survival at the age of 13 years between the two groups. At the age of 7 years, patients who had wheezed had significantly lower forced expiratory flow rate at mid-expiratory phase (85 +/- 34% predicted) compared with those with no wheezing history (101 +/- 34% predicted). At the age of 13 years, forced expiratory volume in 1 second values was lower in the wheezing group (69 +/- 24% predicted vs 78 +/- 21% predicted), as was forced expiratory flow rate at mid-expiratory phase (56 +/- 33% predicted vs 69 +/- 30% predicted). In conclusion, although wheezing in infants with CF seems to have diminished with age, pulmonary function abnormalities were more evident at 7 and 13 years of age in the group that wheezed than in the group that did not.

Cohort Studies↗

Efficacy of adding nebulized ipratropium bromide to nebulized albuterol therapy in acute bronchiolitis.

Nebulized ipratropium bromide is though to be synergistic with albuterol in therapy for acute childhood asthma. Because the efficacy of ipratropium in bronchiolitis is uncertain and some infants with bronchiolitis do not respond to nebulized albuterol alone, the following study was undertaken. In this double-blind, placebo-controlled trial, 69 infants between 6 weeks and 24 months of age who exhibited the first episode of acute bronchiolitis were randomly assigned to receive either nebulized albuterol (0.15 mg/kg per dose) and ipratropium bromide (250 micrograms per dose) (group A, n = 36) or nebulized albuterol and normal saline (placebo) (group B, n = 33) for two doses, 1 hour apart. The two groups were comparable at baseline. Both therapies resulted in clinically significant improvement. However, the addition of ipratropium resulted in no additional benefit with respect to decrease in the respiratory rate (mean decreases 10.6/min vs decreases 8.6/min, P = .86), accessory muscle score (range 0 through 3) (decreases 0.92 vs decreases 0.82, z = -0.44), wheeze score (range 0 through 3) (decreases 0.94 vs 0.85, z = -0.20), oxygen saturation (increases 0.25% vs increases -0.33%, P = .86), or hospitalization rate (17 vs 10). The number of "nonresponders" and "clear responders" was also very similar in both groups. No toxicity was noted. The increase in heart rate was mild and similar in both groups (increases 6.7 vs increases 11.1). The power of the study to detect a difference between the two treatment groups in the respiratory rate change > or = 8/min is greater than 90%.(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Disease↗

Results of the Massachusetts Model Systems for Blood Cholesterol Screening Project.

OBJECTIVE: --To evaluate the effectiveness of a model blood cholesterol screening program. DESIGN: --Principal components included physician education, community-based screenings, and follow-up. A lay or professional educator provided counseling and referral advice. Half of the subjects with high blood cholesterol levels received a reminder to see their physician. SETTING: --135 sites in four Massachusetts communities. PARTICIPANTS: --10,428 adults. Males, the young, the poor, the less educated, and minorities were underrepresented. MAIN OUTCOME MEASURES: --Referral completion rates, blood cholesterol changes. RESULTS: --51.5% of those referred had visited their physicians within 2 to 4 months, increasing to 65.6% within 6 to 12 months. Older age (odds ratio [OR], 1.17 per additional decade), more education (OR, 1.17 per additional level), higher blood cholesterol levels (OR, 1.19 per additional 0.51 mmol/L), previous knowledge of level (OR, 1.34), and receiving a reminder (OR, 1.24) were significantly associated with greater likelihood of referral completion, whereas the type of educator providing counseling was not. Physicians had remeasured the blood cholesterol level of 76% of those seen, given dietary counseling to 70%, and prescribed medication to 15%. Significant changes in dietary fat were reported by both compliers and noncompliers with advice to follow up with their physicians. Six months after screening, blood cholesterol levels were 3.6% lower in noncompliers, 4.4% lower in compliers not taking cholesterol-lowering medications, and 8.8% in compliers taking such medications. CONCLUSIONS: --An effective, community-based blood cholesterol screening program can attract diverse populations and can result in most participants with high levels following up with their physicians, making dietary changes, and lowering their cholesterol levels. Additional strategies may be needed to attract underrepresented groups and to reduce the apparent overuse of cholesterol-lowering medications.

Adult↗

Does cholesterol screening result in negative labeling effects? Results of the Massachusetts Model Systems for Blood Cholesterol Screening Project.

Several previous studies that looked at the effects of labeling individuals as hypertensive found increases in psychosocial distress, diminished feelings of well-being, or absenteeism. Other studies found no such effects. Thus far, similar studies relating to labeling for high blood cholesterol levels have not been published. The Massachusetts Model Systems for Blood Cholesterol Screening Project investigated whether labeling effects occurred as a result of the community-based screening, education, and referral programs it conducted in Worcester and Lowell. Nine questions concerning perceptions of physical and psychological well-being were asked on a questionnaire given to screening participants. The same questions were asked as part of a follow-up questionnaire given to all individuals identified as having high blood cholesterol levels at one of the screenings. Comparison of the baseline and follow-up results did not demonstrate significant overall negative effects among any age, sex, racial, income, or educational groups. On the contrary, responses to many of the questions revealed small but statistically significant improvements in perceptions of physical and psychological well-being. The absence of negative labeling effects may be attributable to the positive, supportive approach to participant counseling taken by the project.

Adult↗

Clinical-physiologic correlations in acute asthma of childhood.

Seventy-one patients who presented to the emergency room with acute asthma were evaluated to determine the relationship between common clinical signs and spirometric and transcutaneous arterial oxygen saturation (SaO2) measurements. Prior to treatment, a physical examination was performed, a clinical score assigned, and pulmonary function and SaO2 were measured. Although forced expiratory volume in 1 second (FEV1) and SaO2 had strong correlation with the overall clinical score (r2 = .47, .49 respectively), many patients with low clinical scores and apparent mild clinical disease had low FEV1 values (as low as 20% predicted). Of the individual components of the clinical score (ie, heart rate, respiratory rate, pulsus paradoxus, accessory muscle use, dyspnea, and wheezing), the degree of accessory muscle use correlated most closely with lung function followed by the degree of dyspnea and wheezing. Similarly, the degree of accessory muscle use correlated most closely with SaO2 followed by dyspnea and respiratory rate. Significant correlation (r2 = .59) was found between SaO2 and FEV1, although the range of SaO2 value for a given FEV1 was wide and some patients with low FEV1 values had normal SaO2 values. These results show that although clinically apparent severe disease and hypoxemia were always associated with low FEV1, their absence does not exclude the presence of airflow obstruction. It is concluded that for the optimal evaluation of acute asthma in children in the emergency room, clinical evaluation should be used in conjunction with objective laboratory measurements.

Acute Disease↗

Sequential pulmonary function measurements during treatment of infantile chronic interstitial pneumonitis.

Three infants with histologically confirmed chronic interstitial pneumonitis were treated with monthly intravenously administered high doses of methylprednisolone with or without daily hydroxychloroquine therapy. We applied the multiple occlusion technique to measure the static respiratory system compliance, and the end-inspiratory occlusion technique to measure passive respiratory system compliance, resistance, and time constant. When assessed by clinical criteria and pulmonary function measurements, all three patients showed improvement with this treatment. Clinical improvement was associated with an increase in respiratory system compliance as measured by both techniques (60% to 100% increase in all patients). The passive respiratory resistance and the time constant did not closely reflect the clinical course. We conclude (1) that high doses (pulses) of methylprednisolone and daily oral doses of hydroxychloroquine are effective in the treatment of infantile chronic interstitial pneumonitis and (2) that the respiratory system compliance, measured by both pulmonary function techniques, correlates well with the response to treatment and change in clinical status.

Airway Resistance↗