PubMed Health⌕ Search

Biomedical subjects

J Robert Freije

Publications and source records attributed to J Robert Freije.

2 recordsLinked to original sources

Activity-based matrix metallo-protease enrichment using automated, inhibitor affinity extractions.

An automated inhibitor affinity extraction method for the activity-based enrichment of matrix metallo-proteases (MMPs) is presented. Samples containing purified MMP-12 were first extracted at different flow rates in a syringe pump setup, using cartridges packed with an MMP inhibitor affinity sorbent based on an immobilized hydroxamic acid containing peptide (PLG-NHOH) with mumol/L MMP affinity. Faster extractions, a reduced number of manual manipulations, and higher extraction yields (98.9%-99.3%) were obtained over the whole flow rate range compared to batch extractions. Application of the method to synovial fluid from a rheumatoid arthritis patient followed by gelatin-zymography revealed a strong enrichment of distinct MMPs from this biological sample that were not clearly visible in the original sample. The use of an auto-sampler and a solid-phase extraction (SPE) workstation allowed full automation of the extraction procedure with the potential for on-line coupling to further sample preparation and analytical steps. MMP-12 extractions were optimized showing that ligand density is an important factor with a clear extraction yield optimum around 5 to 7.5 mmol/L. Conditioning of the stationary phase for 1 week prior to use resulted in a further slight increase in extraction yield. Under optimal conditions, an extraction yield of 99.5% was reached with a cartridge contact time of only 13 s for MMP-12. The efficacy of the extraction method for activity-based MMP profiling was further improved by the use of a broad-spectrum MMP inhibitor with nmol/L affinity (TAPI-2). This resulted in an increased extraction yield for all tested MMPs. For MMP-1, -7, -8, -10, -12, and -13 extraction yields of at least 98.8% were obtained, while for MMP-9 (full length and catalytic domain) an extraction yield of at least 96.1% was reached.

Adsorption↗

Chemically modified, immobilized trypsin reactor with improved digestion efficiency.

Tryptic digestion followed by identification using mass spectrometry is an important step in many proteomic studies. Here, we describe the preparation of immobilized, acetylated trypsin for enhanced digestion efficacy in integrated protein analysis platforms. Complete digestion of cytochrome c was obtained with two types of modified-trypsin beads with a contact time of only 4 s, while corresponding unmodified-trypsin beads gave only incomplete digestion. The digestion rate of myoglobin, a protein known to be rather resistant to proteolysis, was not altered by acetylating trypsin and required a buffer containing 35% acetonitrile to obtain complete digestion. The use of acetylated-trypsin beads led to fewer interfering tryptic autolysis products, indicating an increased stability of this modified enzyme. Importantly, the modification did not affect trypsin's substrate specificity, as the peptide map of myoglobin was not altered upon acetylation of immobilized trypsin. Kinetic digestion experiments in solution with low-molecular-weight substrates and cytochrome c confirmed the increased catalytic efficiency (lower K(M) and higher k(cat)) and increased resistance to autolysis of trypsin upon acetylation. Enhancement of catalytic efficiency was correlated with the number of acetylations per molecule. The favorable properties of the new chemically modified trypsin reactor should make it a valuable tool in automated protein analysis systems.

Acetonitriles↗