Multiple-region gradient arrays for extended field of view, increased performance, and reduced nerve stimulation in magnetic resonance imaging.

This article presents a novel design for magnetic resonance imaging (MRI) gradient systems. This design may allow the development of MRI scanners that are capable of imaging large regions with high performance while minimizing the potential for nerve stimulation. The general concept of the gradient system is that spatial oscillation is incorporated such that each gradient coil creates multiple, approximately linear gradient regions that oscillate in gradient polarity. Separate radiofrequency (RF) coil arrays are designed to be sensitive to the signals within each linear region and thus allow signal measurements to be obtained separately from each region. Enabling image acquisition in the transition region that separates each pair of adjacent linear regions requires a second gradient system with imaging regions that overlap and coincide with the transition regions of the first gradient system. Imaging the extended field of view (FOV) is accomplished by interleaved operation of the two gradient systems. Simulated annealing is used to create designs for both longitudinal and transverse gradient systems with two imaging regions.

Computer Simulation↗

Relative RF coil performance in carotid imaging.

PURPOSE: Computer simulations and measurements on human volunteers were used to test the extent to which the quality of carotid imaging might be improved by coil arrays that are not limited by a constraint on the number of RF coil receiver ports. METHODS: Analytic near-field equations for the magnetic and electric fields of a rectangular loop resonator were used to estimate the relative signal-to-noise ratio (rSNR) along the length of a simulated carotid artery as a function of loop size, loop position and vessel depth. The sizes, positions and number of elements in a linear coil array that resulted in the maximum composite SNR along the length of a simulated carotid artery were then estimated. The linear array results were used to predict the total number of elements needed for optimal imaging of the carotid arteries. Also, three normal volunteers were imaged with a variety of RF coils, and the rSNR measurements along the lengths of the carotid artery were evaluated for each coil combination. RESULTS: The analytic simulation and the human volunteer measurements both show that improved SNR (e.g., >300% at the bifurcation) can be obtained with coils tailored to each specific region of the carotid artery in comparison to that obtained with four-element arrays designed and used to image the entire carotid artery. CONCLUSIONS: The resulting number of coil ports, 16 to 24, required for full coverage of the carotid arteries is consistent with the number of channels just becoming available on recently developed clinical scanners.

Adult↗

Measuring magnetic fields generated by DC currents in receive-only coils.

DC decoupling currents applied to receive-only coils during radiofrequency transmission can create stray magnetic fields capable of changing the resonant frequency of nearby nuclei. It is difficult to measure these fields with conventional field-mapping techniques because the fields are not present when the signal is acquired. The stray fields can be measured empirically with cardiac tags.

Magnetic Resonance Imaging↗