Restenosis after coronary angioplasty: the paradox of increased lumen diameter and restenosis.

Restenosis after coronary angioplasty is the single complication that most limits this revascularization procedure in clinical practice. The process is largely unpredictable and the lesion-related factors predisposing to restenosis are poorly understood, with little consensus in published reports. In this study using detailed quantitative angiographic measurements to assess 490 lesions, the simple lesion characteristics associated with restenosis were defined and the relation to the restenosis process documented. Restenosis was defined as an absolute deterioration in the minimal lumen diameter by greater than or equal to 0.72 mm, a criterion based on the 95% confidence intervals for repeat angiographic measurements. This was chosen in an attempt to separate spurious changes due to a poor angiographic result and the variability of angiographic measurements from significant changes due to the restenosis process. The principal determinants of restenosis were found to be a large improvement in the minimal lumen diameter at the time of dilation (1.13 mm for the restenosis group compared with 0.86 mm for the no restenosis group [p less than 0.0001]) and an optimal postangioplasty result (minimal lumen diameter 2.28 mm in the restenosis group compared with 2.05 mm [p less than 0.001] in the no restenosis group, corresponding to a 25% and a 30% diameter stenosis, respectively [p less than 0.0001]). These observations reported for the first time suggest that the distinction needs to be made between a "clinical restenosis" of greater than or equal to 50% diameter stenosis and the "restenosis process" as measured by the absolute changes occurring during and after angioplasty.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary

Does the measurement of left ventricular isovolumic relaxation time allow early prediction of cardiac allograft rejection?

In order to evaluate the value of isovolumic relaxation time measurement for the diagnosis of moderate acute rejection episodes in cardiac allograft recipients a comparison was made with the histological results from the endomyocardial biopsy. A total of 202 isovolumic relaxation time measurements from 26 patients were compared to the biopsy results. The technique used to record isovolumic relaxation time was dual M-mode echocardiography. In addition a combined phonoechocardiography was used for 54 isovolumic relaxation time measurements from 17 patients. A good correlation was found between these two methods. When the biopsy results were normal the isovolumic relaxation time was 71.4 +/- 15.1 ms. When moderate acute rejection episodes were present isovolumic relaxation time decreased to 50.2 +/- 21.2 ms (p < 0.001). In spite of the close correlation detected at group level, there was a large variability of the measurements without accompanying changes in the biopsy specimen. At the same time a significant overlap was found between the measurements taken during rejection and non-rejection periods making it impossible to use these methods for clinical decision making. We conclude that isovolumic relaxation time measured with these methods is not a sufficiently sensitive parameter for the diagnosis of moderate acute rejection episodes in the individual patient, and in our experience, it is not a substitute for endomyocardial biopsy and can not be applied for clinical decision making.

Adolescent

Does intravenous milrinone have a direct effect on diastolic function?

Bipyridine derivatives have recently been introduced as a new class of inodilator drugs in the intravenous therapy of heart failure. A member of this class is milrinone, which improves the inotropic state and reduces ventricular afterload, leading to improved hemodynamics. Because systolic and diastolic function are intimately related, it can be expected that the diastolic muscle properties are influenced by changes in systolic function and therefore by milrinone therapy. Since end-diastolic pressure may shift as a result of a change in ventricular volume alone, a complete left ventricular diastolic pressure volume (LVDPV) relationship must always be measured before one can make firm conclusions regarding changes in diastolic function. After a LVDPV relationship is obtained, one should identify the variables that can modify this relationship without directly affecting the intrinsic diastolic muscle properties. These variables can be divided into static effects (coronary vascular bed volume, right ventricular pressure, and pericardial pressure) and dynamic effects (viscoelasticity and myocardial active relaxation). Increments in coronary perfusion pressure of perfusion flow (vascular bed volume) are known to stiffen the cardiac wall (turgor effect). Changes in right ventricular pressure or pericardial pressure are other factors affecting the LVDPV relationship by changing transmural pressure. This effect is more pronounced when the ventricle is already stiff, such as in patients with myocardial hypertrophy. Dynamic effects become important when a LVDPV relationship is measured during isolated cardiac cycles; they include viscoelasticity and abnormal myocardial relaxation. Clinical assessment of diastolic cardiac performance assumes a model in which the heart is considered an elastic body (while in fact it is viscoelastic).(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiotonic Agents

The relative contributions of myocardial wall thickness and ischemia to ultrasonic myocardial integrated backscatter during experimental ischemia.

The purpose of this study was to assess the empirical relationship between myocardial integrated backscatter (IB) and myocardial wall thickness (WT) in normal myocardium. A second object was to estimate the additional contribution to acute ischemic integrated backscatter levels given this relationship. Myocardial IB measurements and simultaneous myocardial WT measurements were made in 16 open-chested pigs with intact coronary circulation (normal myocardium) and 10 min after the flow in the left anterior descending coronary artery had been reduced to 20% of its baseline value (ischemic myocardium). Measurements were made 50 times during one cardiac cycle and averaged over 10 cardiac cycles. IB and WT measurements were normalized with respect to the nonischemic end-diastolic values. The relationship between IB and WT in normal myocardium was estimated in every individual pig by simple linear regression. Estimates of IB during ischemia were calculated on the basis of this relationship and the ischemic WT measurements. Differences of the estimator and the actual measurement made during ischemia depict the actual contribution of the state of acute ischemia, without the influence of WT. The slope of the relationship between IB and WT during normal myocardial contraction ranged from -0.16 to 0.03 dB/% (mean = -0.036 dB/%, SD = 0.06 dB/%). The additional contribution of ischemia ranged from -3.84 to 5.56 dB (mean = 0.31 dB, SD = 2.72 dB). It was concluded that the average contribution of ischemia to IB measurements is insignificant if the IB dependency on WT is removed from the data and that the higher level of ischemic IB measurements can be explained by the decrease in wall thickness during ischemia and not by the ischemia itself.

Animals

Quantitative angiography after directional coronary atherectomy.

OBJECTIVE: To assess by quantitative analysis the immediate angiographic results of directional coronary atherectomy. To compare the effects of successful atherectomy with those of successful balloon dilatation in a series of patients with matched lesions. DESIGN: Case series. SETTING: Tertiary referral centre. PATIENTS: 62 patients in whom directional coronary atherectomy was attempted between 7 September 1989 and 31 December 1990. INTERVENTIONS: Directional coronary atherectomy. MAIN OUTCOME MEASURES: Increase in minimal luminal diameter of coronary artery segment. RESULTS: Angiographic success on the basis of intention to treat was obtained in 54 patients (87%). In four patients the lesion could not be crossed by the atherectomy device; all four had an uneventful conventional balloon angioplasty. Four of the 58 patients who underwent atherectomy were subsequently referred for coronary bypass surgery because of failure or complications; three of them sustained a transmural infarction. In the successful cases, coronary atherectomy resulted in an increase in the minimal luminal diameter from 1.1 mm to 2.5 mm with a concomitant decrease of the diameter stenosis from 62% to 22%. In the subset of 37 patients in which the changes induced were compared with conventional balloon angioplasty atherectomy increased the minimal luminal diameter more than balloon angioplasty (1.6 v 0.8 mm; p less than 0.0001). Conventional histology showed media or adventitia in 26% of the atherectomy specimens. In hospital complications occurred in six patients who had undergone a successful procedure: two transmural infarctions, two subendocardial infarctions, one transient ischaemia attack, and one death due to delayed rupture of the atherectomised vessel. All patients were clinically evaluated at one and six months. One patient had persisting angina (New York Heart Association class II), one patient sustained a myocardial infarction, one patient underwent a percutaneous transluminal coronary angioplasty for early restenosis, and one patient underwent coronary bypass surgery because of a coronary aneurysm formation. At six months 80% (36/47) of the patients were symptom free. CONCLUSIONS: Coronary atherectomy achieved a better immediate angiographic result than balloon angioplasty; however, in view of the complication rate in this preliminary series, which may be related to a learning curve, a randomised study is needed to show whether this procedure is as safe as a conventional balloon angioplasty.

Angioplasty, Balloon, Coronary

Recovery of regional myocardial dysfunction after successful coronary angioplasty early after a non-Q wave myocardial infarction.

More aggressive therapy has been suggested for patients who have a non-Q wave myocardial infarction (MI) because of the frequency of subsequent unstable angina, recurrent MI, and high mortality rate compared to patients with Q wave MI. The present study was undertaken to investigate the effect of coronary angioplasty on regional myocardial function of the infarct zone in patients with angina early after a non-Q wave MI. The study population consisted of 36 patients undergoing successful coronary angioplasty within 30 days of a non-Q wave MI, in whom sequential left ventricular angiograms of adequate quality were obtained before the initial procedure and at follow-up angiography. The global ejection fraction increased significantly from 60 +/- 9% to 67 +/- 6% (p = 0.0003). This significant increase in the global ejection fraction was primarily due to a significant improvement in the regional myocardial function of the infarct zone. The results of the present study show not only that ischemic attacks early after a non-Q wave MI may lead to prolonged regional myocardial dysfunction but more important that this depressed myocardium has the potential to achieve normal contraction after successful coronary angioplasty.

Angiography

Ultrasonic myocardial integrated backscatter and myocardial wall thickness in animal experiments.

The purpose of this study was to distinguish between normal and ischemic myocardium using ultrasonic integrated backscatter (IB) measurements and to relate IB with myocardial wall thickness. IB was measured in 9 open-chested Yorkshire pigs (24-30 kg) before, after 30 minutes of partial occlusion of the proximal left anterior descending coronary artery (LADCA), and after 60 minutes of subsequent reperfusion. The ultrasound transducer (4 MHz) was sutured onto the epicardial surface perfused by the LADCA. IB measurements were made with a repetition rate of 50 times per heart rate simultaneously with a left ventricular pressure signal. Myocardial wall thickness was measured off-line. The measurements of integrated backscatter, left ventricular pressure and wall thickness were based on mean values of ten subsequent cardiac cycles. End-systolic IB measurements were 5.3 dB higher during occlusion as compared to the reference measurements (7.1 +/- 3.2 dB versus 1.8 +/- 2.6 dB; p = 0.002). No statistically significant differences were found in end-systolic IB measurements. End-systolic wall thickness was 5 mm smaller during occlusion as compared to the reference measurements (7.2 +/- 1.4 mm versus 12.2 +/- 1.2 mm; p less than 0.001). Simple linear regression analysis showed a statistically significant inverse relationship between IB measurements and wall thickness in 21 out of the 23 sequences in which wall thickness could be measured. End-systolic IB measurements are favourable to distinguish acute ischemic myocardium from normal myocardium. There is a distinct inverse relationship between IB and myocardial wall thickness.

Animals

The reproducibility of continuous wave Doppler measurements in the assessment of mitral stenosis or mitral prosthetic function: the relative contributions of heart rate, respiration, observer variability and their clinical relevance.

The reproducibility of continuous wave Doppler echocardiographic measurements of transmitral diastolic flow velocity were studied in terms of bias and random error in 40 patients with either mitral stenosis or a Björk-Shiley mitral valve prosthesis. Twenty-seven patients were in sinus rhythm; 13 patients had atrial fibrillation. Intra- and interobserver differences in bias were small for the Doppler parameters studied i.e. early peak velocity (0.6% vs 3.6%), mean diastolic velocity (1.1% vs 8.6%), mean temporal velocity (2.3% vs 14.5%) and pressure half-time (2.7% vs 4.8%). The overall random error of the measurements (in terms of twice the standard deviation) was estimated separately in patients in sinus rhythm and atrial fibrillation: early peak velocity 5.6% and 9.2%, respectively, mean diastolic velocity 9.4% and 22%, mean temporal velocity 8.6% and 19% and pressure half-time 34% and 46%. The relative contributions to the overall random error of observer variation, heart rate dependency and respiratory variation were also studied. Heart rate dependency was demonstrated for both the mean diastolic velocity and the pressure half-time. Respiratory variation was found in the early peak velocity. From the results of this study the number of measurements to reduce the random error of the final average could be determined. Our results indicate that for the measurements in which a respiratory effect is present it is advisable to average the measurements taken over complete respiratory cycles.

Blood Flow Velocity

The design, construction and clinical evaluation of a small phased array transducer for intraoperative echocardiography.

A small probe for cardiac surgery was developed and clinically tested. The probe is built as a phased array transducer with 64 elements with a centerfrequency of 5 MHz. The transducertip is connected with a handle by a flexible yet steerable shaft. This shaft has a length of 10 cm and can be set in a desired shape. Good quality images were obtained in all patients. The first study suggest many applications for a small probe in intraoperative echocardiography.

Cardiac Surgical Procedures

Echocardiography in diagnosis of aortic dissection.

In a multicentre study the accuracy of echocardiography was measured in 164 consecutive patients with suspected aortic dissection. The diagnosis was subsequently proven (82 patients) on the basis of transthoracic and transoesophageal echocardiography and additional diagnostic procedures, including computed tomography (CT), aortic angiography, and surgery and/or necropsy. The sensitivity and specificity of echocardiography were 99% and 98%, respectively, with positive and negative predictive values of 98% and 99%. For CT sensitivity was 83%, specificity 100%, and positive and negative predictive values 100% and 86%, respectively. For aortography sensitivity and specificity were 88% and 94%, and the positive and negative predictive values 96% and 84%, respectively. Echocardiography, including the transoesophageal route, can provide accurate diagnosis of aortic dissection within 15 min. Diagnostic difficulties occur only in a few type II dissections, when complementary diagnostic procedures, including CT or angiography, may be needed. To clarify branch involvement angiography is required.

Acute Disease

Arterial wall characteristics determined by intravascular ultrasound imaging: an in vitro study.

The feasibility of assessing arterial wall configuration with an intravascular 40 MHz ultrasound imaging device was investigated in an in vitro study of 11 autopsy specimens of human arteries. The system consists of a single element transducer, rotated with a motor mounted on an 8F catheter tip. Cross sections obtained with ultrasound were matched with the corresponding histologic sections. The arterial specimens were histologically classified as of the muscular or elastic type. Muscular arteries interrogated with ultrasound presented with a hypoechoic media, coinciding with the smooth muscle cells. In contrast, the media of an elastic artery densely packed with elastin fibers was as echogenic as the intima and the adventitia. On the basis of the cross-sectional image, it was possible to determine the nature of the atherosclerotic plaque. The location and thickness of the lesion measured from the histologic sections correlated well with the data derived from the corresponding ultrasound images. This study indicates that characterization of the type of artery and detection of arterial wall disease are possible with use of an intravascular ultrasound imaging technique.

Adult

Intravascular ultrasonic imaging: histologic and echographic correlation.

The feasibility of assessing arterial wall characteristics with an intravascular 40 MHz ultrasonic imaging device was determined in vitro. Ten autopsy specimens of human arteries, with and without atherosclerosis, were studied. A close relationship was observed between the histologic section and the corresponding ultrasonic cross-section with regard to the location, maximum plaque thickness and extent of the atherosclerotic lesion along the circumference of the vessel wall. Based on echogenicity of the atherosclerotic lesion, ultrasound could distinguish four basic types of atherosclerotic plaque components: 1. hypoechoic: a reflection of lipid deposits; 2. soft echoes: reflective of fibromuscular tissue; 3. bright echoes: representative of fibrous tissue; 4. bright echoes with shadowing behind the lesion: representative of calcium deposits. It is anticipated that development of such a catheter-tip imaging system combined with recanalisation methods will be of immense benefit for the precise localisation and identification of vessel wall pathology, precise positioning of a recanalisation instrument (laser device, atherectomy catheter) and subsequent use of this recanalisation procedure and for assessing the effect of recanalisation.

Adult

What is the ideal orientation of a mitral disc prosthesis? An in vivo haemodynamic study based on colour flow imaging and continuous wave Doppler.

Doppler colour flow imaging demonstrates normal laminar flow to enter the left ventricle in diastole through the mitral inflow tract located posteriorly in the left ventricle. Laminar flow then passes around the left ventricular apex to the anteriorly located outflow tract. As this is the normal physiologic flow pattern, it would seem appropriate that in the surgical implantation of a mitral tilting disc prosthesis the greater orifice should be directed posteriorly to mimic the normal native valve flow pattern. To determine whether variable positioning of the greater orifice had any significant haemodynamic consequences, intracavitary blood flow patterns were studied in 30 patients with mitral Björk-Shiley prostheses variously orientated in the mitral orifice. The orientation of the greater orifice (OGO) of the prosthesis was determined by fluoroscopy and the pattern of the left ventricular inflow from Doppler colour flow imaging. Twelve patients had their OGO and inflow directed towards the inflow tract (orientation I): nine patients had their OGO and inflow directed anteriorly towards the outflow tract (orientation II) and nine patients had their prosthesis with OGO and inflow in an intermediate position (orientation III). The mean prosthetic diastolic gradient, calculated using continuous wave Doppler, averaged 2.8 mmHg (+/- 0.5 mmHg) for the 25-mm prosthesis in orientation I, but 6.0 mmHg (+/- 0.7 mmHg) for the same size prosthesis in orientation II and 5.8 mmHg (+/- 0.9 mmHg) with a 25-mm prosthesis in orientation III. Similarly, for prostheses of 27 mm and 29-31 mm the lowest mean diastolic gradient was found in orientation I (2.7 mmHg +/- 0.8 and 2.8 mmHg +/- 0.5, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

A comparison of two methods to measure coronary flow reserve in the setting of coronary angioplasty: intracoronary blood flow velocity measurements with a Doppler catheter, and digital subtraction cineangiography.

Intracoronary blood flow velocity measurements with a Doppler balloon catheter and the radiographic assessment of myocardial perfusion with contrast media, before and after the intracoronary administration of papaverine, have previously been used to investigate regional coronary flow reserve. In the present study we applied both techniques in 21 patients to measure coronary flow reserve in the setting of coronary angioplasty. Pre-angioplasty (N = 14) and post-angioplasty (N = 19) measurements of coronary flow reserve were obtained by digital subtraction cineangiography in the myocardial region supplied by the dilated coronary artery, and with the Doppler probe in the proximal part of the dilated vessel. The reactive hyperaemia following the final balloon inflation was recorded with the Doppler balloon catheter still positioned across the stenotic lesion. Coronary stenosis geometry was quantified with the Cardiovascular Angiography Analysis System. When the epicardial stenosis was the only factor causing a reduction in coronary flow reserve, flow reserve measured with both digital subtraction cineangiography and with the Doppler probe correlated well with the cross-sectional area at the site of obstruction, r = 0.88, SEE = 0.36 and r = 0.77, SEE = 0.45 respectively. In contrast, when other factors decreasing coronary flow reserve were present (intimal dissection, left ventricular hypertrophy, previous myocardial infarction, collaterals) measurements obtained with both techniques correlated poorly with cross-sectional area (r = 0.55, SEE = 0.57, and r = 0.59, SEE = 0.50). Flow reserve measurements obtained with digital subtraction cineangiography correlated well with the measurements obtained with the Doppler probe (r = 0.85, SEE = 0.38, and r = 0.87, SEE = 0.34), although the two approaches have methodologically nothing in common and their respective regions of interest (myocardium for the radiographic technique and intracoronary lumen for the Doppler technique) are basically different. Furthermore, the reactive hyperaemia following the final balloon inflation was related to the flow reserve measured with both the angiographic technique (r = 0.85, SEE = 0.34) and the Doppler technique (r = 0.83, SEE = 0.32) using pharmacologically induced coronary vasodilation with intracoronary papaverine. This suggests that the same quantity of coronary flow reserve that can be recruited pharmacologically can be recruited by ischaemia following a transluminal occlusion.

Adult