[Patient with pallor, fatigue, weight loss. LDH values need explanation].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Rosengarten.
Explore the source record for details and available documents.
For 11 consecutive prostate cancer patients undergoing three-dimensional conformal radiotherapy (3DCRT) in our institution, penile structures (PNS) were outlined in CT images obtained for treatment planning purposes. Dose-volume histograms (DVHs) were compared in order to study dose-volume relations for three techniques: 4FLD, an axial coplanar, four-field box technique; 6FLD, a six-field coplanar technique; and 4NAX, a coplanar but non-axial, four-field technique. All three techniques delivered equal doses to the planning target volumes (PTV). Our statistical analyses strongly indicate that the three techniques can be ranked as 6FLD better than 4FLD (and 4FLD better than 4NAX) as far as irradiating PNS volume during treatment of prostate cancer (PC) is concerned. For each technique, there is a "spread" owing to differences in patient anatomy and/or target size, position, and extent, but each technique has a similar "profile" or "shape" distinct from other techniques. Whether irradiating smaller volumes of PNS will influence the sexual potency outcome remains to be demonstrated. However, PNS should be considered as another critical structure in addition to rectum, bladder and femoral heads in the radiotherapy (RT) of PC, especially in 3DCRT dose escalation studies. Sexual potency outcomes can be correlated to dose-volume relations in the future and this will help refine radiotherapy techniques further.
In 1974 we began a prospective study of a cohort of 4296 individuals exposed to therapeutic head and neck irradiation during childhood for benign conditions. To define the role of thyroid ultrasonography in following irradiated individuals, we studied a subgroup of 54 individuals. They all had been screened between 1974-1976 and had normal thyroid scans and no palpable nodules at that time. Thyroid ultrasonography, thyroid scanning, physical examination, and serum thyroglobulin measurements were performed. One or more discrete ultrasound-detected nodules were present in 47 of 54 (87%) subjects. There were a total of 157 nodules, 40 of which were 1.0 cm or larger in largest dimension. These 40 nodules occurred in 28 (52%) of the subjects. Thirty (75%) of these 1.0-cm or larger nodules matched discrete areas of diminished uptake on corresponding thyroid scans. The 10 that did not match (false negative scans for > or = 1.0-cm nodules) were the only nodules of this size in 7 subjects. Of 11 nodules 1.5 cm or larger, only 5 were palpable. Serum thyroglobulin correlated to the number (P = 0.04; r2 = 0.10), but not the volume of the thyroid nodules (P = 0.07; r2 = 0.08). We conclude that thyroid nodules are continuing to occur and are exceedingly common in this irradiated cohort of individuals. The results confirm that thyroid ultrasonography is more sensitive than physical examination and scanning. However, thyroid ultrasound is so sensitive and nodules so prevalent that great caution is needed in interpreting the results.
Explore the source record for details and available documents.