PubMed Health⌕ Search

Biomedical subjects

J S Aldridge

Publications and source records attributed to J S Aldridge.

4 recordsLinked to original sources

Registration using tomographic projection files.

An algorithm has been developed and experimentally verified for tomographic registration--a patient positioning method using internal anatomy and standard external fiducial marks. This algorithm improves patient set-up and verification to an accuracy sufficient for tomotherapy. By implementation of this technique, the time-consuming reconstruction process is avoided. Instead, offsets in the x, y and z directions are determined directly from sinogram data by an algorithm that utilizes cross-correlations and Fourier transforms. To verify the efficiency and stability of the algorithm, data were collected on the University of Wisconsin's dedicated tomotherapy research workbench. The experiment indicates offset statistical errors of less than +/-0.8 mm for offsets up to 30 mm. With standard clinical techniques, initial patient offsets are expected to be less than 5 mm, so the 30 mm limitation is of no consequence. The angular resolution for the direction of patient translation is within the +/-2 degrees needed for tomotherapy.

Algorithms↗

Image/patient registration from (partial) projection data by the Fourier phase matching method.

A technique for 2D or 3D image/patient registration, PFPM (projection based Fourier phase matching method), is proposed. This technique provides image/patient registration directly from sequential tomographic projection data. The method can also deal with image files by generating 2D Radon transforms slice by slice. The registration in projection space is done by calculating a Fourier invariant (FI) descriptor for each one-dimensional projection datum, and then registering the FI descriptor by the Fourier phase matching (FPM) method. The algorithm has been tested on both synthetic and experimental data. When dealing with translated, rotated and uniformly scaled 2D image registration, the performance of the PFPM method is comparable to that of the IFPM (image based Fourier phase matching) method in robustness, efficiency, insensitivity to the offset between images, and registration time. The advantages of the former are that subpixel resolution is feasible, and it is more insensitive to image noise due to the averaging effect of the projection acquisition. Furthermore, the PFPM method offers the ability to generalize to 3D image/patient registration and to register partial projection data. By applying patient registration directly from tomographic projection data, image reconstruction is not needed in the therapy set-up verification, thus reducing computational time and artefacts. In addition, real time registration is feasible. Registration from partial projection data meets the geometry and dose requirements in many application cases and makes dynamic set-up verification possible in tomotherapy.

Algorithms↗

A proposal for a standard electronic anthropomorphic phantom for radiotherapy.

To create a database of human male and female computed tomography (CT) slices, the National Library of Medicine organized the "Visible Human Project." Since the male and female data sets provided are approximately 269 MB and 915 MB, respectively, both the size and complexity have been reduced. While making the slices accessible to those with limited computing resources, the production of these reduced data sets also presents a unique opportunity to establish a standard human CT slice library for research in radiation therapy. A brief history of the original data sets is included, as well as details of the reduction process, applications to radiotherapy, and information on accessing these reduced image files.

Adult↗

Registration of synthetic tomographic projection data sets using cross-correlation.

Tomographic registration, a method that makes possible accurate patient registration directly from projection data, consists of three processing steps: (i) manual coarse positioning, (ii) tomographic projection set acquisition, and (iii) computer mediated refined positioning. In the coarse positioning stage, the degree of patient alignment is comparable with that achieved with the standard radiotherapy set-up. However, the accuracy requirements are somewhat more relaxed in that meticulous alignment of the patient using external laser indicators is not necessary. Instead, tomographic projection sets are compared with planning CTs in order to achieve improved patient set-up. The projection sets are cross-correlated to obtain the best-fit translation and rotation offsets. The algorithm has been tested on synthetic data with the incorporation of varying amounts of Gaussian pseudo-random noise. These tests demonstrate the algorithm's stability and also confirm that alignment can be achieved with an accuracy of less than one projection pixel.

Algorithms↗