PubMed Health⌕ Search

Biomedical subjects

J S Day

Publications and source records attributed to J S Day.

At least 19 recordsLinked to original sources

Interrelationships between electrical properties and microstructure of human trabecular bone.

Microstructural changes, such as reduction of trabecular thickness and number, are characteristic signs of osteoporosis leading to diminished bone strength. Electrical and dielectric parameters might provide diagnostically valuable information on trabecular bone microstructure not extractable from bone mineral density measurements. In this study, structural properties of human trabecular bone samples (n=26) harvested from the distal femur and proximal tibia were investigated using the computed microtomography (microCT) technique. Quantitative parameters, e.g. structural model index (SMI) or trabecular bone volume fraction (BV/TV), were calculated. In addition, the samples were examined electrically over a wide frequency range (50 Hz-5 MHz) using a two-electrode impedance spectroscopy set-up. Relative permittivity, loss factor, conductivity, phase angle, specific impedance and dissipation factor were determined. Significant linear correlations were obtained between the dissipation factor and BV/TV or SMI (|r| 0.70, p<0.01, n=26). Principal component analyses, conducted on electrical and structural parameters, revealed that the high frequency principal component of the dissipation factor was significantly related to SMI (r=0.72, p<0.01, n=26). The linear combination of high and low frequency relative permittivity predicted 73% of the variation in BV/TV. To conclude, electrical and dielectric parameters of trabecular bone, especially relative permittivity and dissipation factor, were significantly and specifically related to a trabecular microstructure as characterized with microCT. The data gathered in this study constitute a useful basis for theoretical and experimental work towards the development of impedance spectroscopy techniques for detection of bone quality in vitro or in special cases of open surgery.

Bone Density↗

Prediction of mechanical properties of human trabecular bone by electrical measurements.

In trabecular bone, the interrelationships of electrical and dielectric properties with mechanical characteristics are poorly known. Information on these relations is crucial for evaluation of the diagnostic potential of impedance techniques. In this study, electrical and dielectric properties, i.e. permittivity, conductivity, phase angle, loss factor, specific impedance and dissipation factor of human trabecular bone samples (n=26, harvested from the distal femur and proximal tibia) were characterized in a wide frequency range (50 Hz-5 MHz). Mechanical properties, i.e. Young's modulus, ultimate strength, yield stress, yield strain and resilience of the samples (n=20) were determined by using destructive compressive testing. Subsequently, measurements of electrical and dielectric properties were repeated after mechanical testing. The measurements were also repeated for the control samples (n=6) that were not mechanically tested. Electrical, dielectric or mechanical properties showed no significant differences between the intact femoral and tibial samples. The electrical and dielectric parameters as well as the linear correlations between the dielectric and electrical parameters with mechanical parameters were strongly frequency dependent. At the frequency of 1.2 MHz, the relative permittivity showed the strongest linear correlations with the Young's modulus (r=0.71, p<0.01, n=20) and ultimate strength (r=0.73, p<0.01, n=20). Permittivity and dissipation factor showed statistically significant changes after mechanical testing. Our results suggest that the measurements of low frequency electrical and dielectric properties may provide information on the mechanical status of trabecular bone and, possibly, may even help to diagnose bone microdamage. In the future, these measurement techniques may be further developed for use during open surgery, such as bone grafting or total hip replacement surgery.

Algorithms↗

Detecting and tracking local changes in the tibiae of individual rats: a novel method to analyse longitudinal in vivo micro-CT data.

In this study we present the analysis of in vivo micro-CT scans using a new method based on image registration that accurately evaluates longitudinal micro-CT studies. We tested if detailed changes in the bone architecture could be detected and tracked in individual animals. A prototype in vivo micro-CT scanner (Skyscan 1076) was developed in which tibiae of rats that are lying on a bed under gas anaesthesia were scanned. For this study, three female Wistar rats were used: a sham-operated rat, an ovariectomised (OVX) rat and one rat that served as a reproducibility control. The reproducibility control rat was scanned twice in 1 day. The other animals were scanned at week 0, just before surgery, at week 4 and at week 14 after surgery. Architectural changes over time were detected by overlaying two data sets made at different time points using an algorithm that uses mutual information for optimal registration. The scans were segmented into binary data sets using a local thresholding algorithm. The reproducibility test showed small errors of less than 3% in bone volume measurements and errors less than 0.5% in measurements of trabecular thickness. The sham-operated rat showed no changes in total bone volume, though thinning and eventual loss of some small trabeculae could be detected, which could be related to the age of the animal. The OVX rat lost much trabecular bone volume, especially in the metaphysis (60% at week 4, 75% at week 14). The remaining trabeculae slowly increased in thickness. Following the different scans in time showed the forming of new trabecular structures. Additionally, small longitudinal growth at the growth plate could be detected after the first 4 weeks. Further, the OVX rat showed extensive modelling at the proximal endosteal lateral cortex. We have shown a new method that can detect and track changes in the local bone architecture and individual trabeculae in time, in an individual living animal. This method enables longitudinal in vivo micro-CT studies and has the potential to greatly contribute to experimental rat or mouse studies on pharmacological intervention and transgenic models.

Animals↗

Bisphosphonate treatment affects trabecular bone apparent modulus through micro-architecture rather than matrix properties.

Bisphosphonates are emerging as an important treatment for osteoporosis. But whether the reduced fracture risk associated with bisphosphonate treatment is due to increased bone mass, improved trabecular architecture and/or increased secondary mineralization of the calcified matrix remains unclear. We examined the effects of bisphosphonates on both the trabecular architecture and matrix properties of canine trabecular bone. Thirty-six beagles were divided into a control group and two treatment groups, one receiving risedronate and the other alendronate at 5-6 times the clinical dose for osteoporosis treatment. After one year, the dogs were killed, and samples from the first lumbar vertebrae were examined using a combination of micro-computed tomography, finite element modeling, and mechanical testing. By combining these methods, we examined the treatment effects on the calcified matrix and trabecular architecture independently. Conventional histomorphometry and microdamage data were obtained from the second and third lumbar vertebrae of the same dogs [Bone 28 (2001) 524]. Bisphosphonate treatment resulted in an increased apparent Young's modulus, decreased bone turnover, increased calcified matrix density, and increased microdamage. We could not detect any change in the effective Young's modulus of the calcified matrix in the bisphosphonate treated groups. The observed increase in apparent Young's modulus was due to increased bone mass and altered trabecular architecture rather than changes in the calcified matrix modulus. We hypothesize that the expected increase in the Young's modulus of the calcified matrix due to the increased calcified matrix density was counteracted by the accumulation of microdamage.

Alendronate↗

Altered tissue properties induce changes in cancellous bone architecture in aging and diseases.

The mechanical properties of cancellous bone depend on its architecture and the tissue properties of the mineralized matrix. The architecture is continuously adapted to external loads. In this paper, it was assumed that changes in tissue properties leading to changes in tissue deformation can induce adaptation of the architecture. We asked whether changes in cancellous bone architecture with aging and in e.g. early osteoarthrosis can be explained from changes in tissue properties. This was investigated using computer models in which the cancellous architecture was adapted to external loads. Bone tissue with deformations below a certain threshold was resorbed, deformations above another threshold induced formation. Deformations between these two boundaries, in the 'lazy zone', did not induce bone adaptation. The effects of changes in bone tissue stiffness on bone mass, global stiffness and architecture were investigated. The bone gain (40-60%) resulting from a 50% decrease in tissue stiffness (simulating diseased tissue) was much larger than the bone loss (2-30%) resulting from a 50% increase in tissue stiffness (simulating highly mineralized, old tissue). The adaptation induced by a decrease in tissue stiffness resulted in an almost constant stiffness in the main load bearing direction, but the transversal stiffness decreased. An increased tissue stiffness resulted in a higher stiffness in the main direction and overcompensation in the transversal directions: the global stiffness could become even smaller than the stiffness of the original model. Concluding, we showed that changes in trabecular bone in aging and diseases can be partly explained from changes in tissue properties.

Adaptation, Physiological↗

Interrelationships among physicochemical properties, absorption and anthelmintic activities of 2-desoxoparaherquamide and selected analogs.

The interrelationships between physicochemical properties, absorption and potency of 2-desoxoparaherquamide and five analogs, representing a new anthelmintic class, were evaluated in in vitro and in vivo assays. At pH 7.5, rates of drug absorption by the gastrointestinal nematode Haemonchus contortus and jird small intestine, parameterized by the permeability coefficient, P(e), ranged from 1.2-2.4 x 10(-4) cm/min (nematode) to 2.5-5.5 x 10(-3) cm/min (jird). In the jird intestine, absorption was pH-dependent, with P(e) at pH 7.5 being twice that at pH 4.5, reflecting the negative influence of protonation on transport of these weakly basic molecules. Each compound rapidly paralyzed H. contortus during in vitro exposure to therapeutically relevant concentrations (1-10 microm). The kinetics of drug action on motility in vivo mirrored their in vitro effects; motility concentrations were reduced in nematodes collected from jird stomach 3 h following oral drug dosing, by which time > or =50% clearance of the parasites had occurred. The nematode/medium partition coefficient K ranged from 10.1 to 16.1, consistent with the lipophilic nature of the compounds. The time required to reduce motility in vitro by 50% (t50*) and P(e) were used to determine C(n)*, the concentration of drug in the nematode at t50*, as an indicator of intrinsic potency. In the jird, the apparent potencies of the compounds were insensitive to route of administration (i.e. oral = i.v. = i.p. = i.m.) for H. contortus and two other gastrointestinal nematodes, Ostertagia ostertagi and Trichostrongylus colubriformis; topical administration, however, required three to 10-fold higher doses for equivalent efficacy.

Absorption↗

Adaptation of subchondral bone in osteoarthritis.

Osteoarthritis is a chronic joint disease with pathological changes in the articulating cartilage and all other tissues that occupy the joint. Radin and coworkers have suggested the involvement of subchondral bone in the disease process. However, evidence for an essential role in the etiology has never been proven. Recent studies showing reduced chemical and mechanical properties of subchondral bone in various stages of the disease have invigorated interest in the role of subchondral bone in the development and progression of the disease. The current study showed that the concept of bone adaptation might explain subchondral stiffening, a process where subchondral bone becomes typically sclerotic in osteoarthritis. In addition, we report reduced mechanical matrix tissue properties as well as an increase in denatured collagen content. In conclusion, although osteoarthritic bone tissue contains increased denatured collagen and has reduced matrix mechanical properties, the widely accepted concept of subchondral stiffening is compatible with the process of normal bone adaptation.

Biomechanical Phenomena↗

Canine cancellous bone microarchitecture after one year of high-dose bisphosphonates.

We examined the effects of one-year high-dose bisphosphonates (risedronate 0.5 mg/kg/day or alendronate 1.0 mg/kg/day) on the three-dimensional (3-D) microstructural and mechanical properties of canine cancellous bone. A high-resolution micro-CT scanner was used to scan cubic specimens produced from the first lumbar vertebrae. Microstructural properties of the specimens were calculated directly from the 3-D datasets and the mechanical properties of the specimens were determined. Our data demonstrate significant microarchitectural changes in the bisphosphonate-treated cancellous bone that was typically plate-like, denser, with thicker and more trabeculae compared with those of the controls. Consistent with architectural changes, the Young's moduli of cancellous bone increased in all three directions with the greatest increase in primary axial loading (cephalo-caudal) direction after treatment. Our results suggest a bone remodeling-adaptation mechanism stimulated by bisphosphonates that increases bone volume fraction, thickens trabeculae, changes trabeculae towards more plate-like, and increases mechanical properties. The secondary degree of anisotropy contributed significantly to the explained variance in bone strength, and the primary or tertiary degree of anisotropy improved the explanation of variances for Young's moduli, i.e., 79% of strength variances or 74-83% of modulus variances could be explained by the combined anisotropy and bone volume fraction. These significant improvements of cancellous bone architecture provide a rationale for the clinical observation that fracture risk decreased by 50% in the first year of bisphosphonate therapy with only a 5% increase in bone mineral density. We conclude that bisphosphonates enhance mechanical properties and reduce fracture risk by improving architectural anisotropy of cancellous bone 3-D microarchitecture.

Alendronate↗

Effects of short-term alendronate treatment on the three-dimensional microstructural, physical, and mechanical properties of dog trabecular bone.

The bisphosphonate, alendronate, is well known for its potent inhibition of osteoclast-mediated bone resorption. It has been used clinically for the treatment of osteoporosis and has also recently been used to reduce osteolysis around prostheses in a canine revision model of implant loosening (femoral condyle). In this study, the effects of alendronate on trabecular bone properties were assessed in dogs at an oral dose of 0.5 mg/kg per day over a 12 week period, and compared with control dogs. Cubic cancellous bone specimens were produced from lumbar vertebrae (L-1 and L-2) and bilateral proximal humeri. These specimens were scanned using a high-resolution microcomputed tomography (micro-CT) system. From accurate data sets, three-dimensional microstructural properties were calculated and physical and mechanical properties were determined. Treatment with alendronate increased bone volume fraction by 9.5%, 7.7%, 7.4%, and 18.4%, respectively, in L-1, L-2, humeral greater tuberosity, and humeral head trabecular bone. In the lumbar vertebrae, the alendronate-treated trabeculae were thicker and lower in bone surface-to-volume ratio. In the greater tuberosity, the alendronate-treated trabeculae were thicker, lower in bone surface-to-volume ratio, and less anisotropic. In the humeral head, the alendronate-treated trabeculae were thicker, less anisotropic, lower in surface density, and showed decreased trabecular separation. Alendronate significantly increased apparent density and collagen density in the lumbar vertebrae and humeral heads, and significantly decreased collagen concentration in the vertebrae. In the lumbar vertebrae, Young's modulus in the cephalocaudal direction, ultimate stress, and failure energy were significantly increased in the alendronate-treated group. The changes in mechanical properties in the humeral head trabecular bone were similar to those seen in the lumbar vertebrae. Our results demonstrate that alendronate increases the mechanical properties of healthy canine trabecular bone after short-term treatment. The physical and microstructural changes of trabecular bone are consistent with the significantly increased mechanical properties.

Alendronate↗

A decreased subchondral trabecular bone tissue elastic modulus is associated with pre-arthritic cartilage damage.

In osteoarthritis, one postulate is that changes in the mechanical properties of the subchondral bone layer result in cartilage damage. The goal of this study was to examine changes in subchondral trabecular bone properties at the calcified tissue level in the early stages of cartilage damage. Finite element models were constructed from microCT scans of trabectilar bone from the proximal tibia of donors with mild cartilage damage and from normal donors. In the donors with cartilage damage, macroscopic damage was present only in the medial compartment. The effective tissue elastic moduli were determined using a combination of finite element models and mechanical testing. The bone tissue modulus was reduced by 60% in the medial condyle of the cases with cartilage damage compared to the control specimens. Neither the presence of cartilage damage nor the anatomic site (medial vs. lateral) affected the elastic modulus at the apparent level. The volume fraction of trabecular bone was higher in the medial compartment compared to the lateral compartment of tibiae with cartilage damage (but not the controls), suggesting that mechanical properties were preserved in part at the apparent level by an increase in the bone volume fraction. It seems likely that the normal equilibrium between cartilage properties, bone tissue properties and bone volume fraction is disrupted early in the development of osteoarthritis.

Aged↗

Transport of model peptides across Ascaris suum cuticle.

Several FMRFamide-related peptides (FaRPs) found in nematodes exert potent excitatory or inhibitory effects on the somatic musculature of Ascaris suum and other nematode species when injected into the pseudocoelom or applied directly to isolated neuromuscular preparations. These peptides, however, generally fail to induce detectable effects on the neuromusculature when applied externally to intact nematodes. The apparent lack of activity for these peptides when administered externally in whole-organism assays is likely a function of both absorption and metabolism. To delineate the factors that govern transport of peptides across the cuticle/hypodermis complex of nematodes, we measured the rates of absorption of a series of structurally related model peptides using isolated cuticle/hypodermis segments from A. suum and two-chamber diffusion cells. [14C]-Labeled peptides were prepared from D-phenylalanine, with the amide nitrogens sequentially methylated to give AcfNH2, Acf3NH2, Acf(NMef)2NH2, and Ac(NMef)3NHMe. These model peptides were designed to allow systematic analysis of the influence of peptide size, hydrogen bonding and lipophilicity on transport. Results of these studies show that, within this series, permeability across the cuticle increases with addition of each methyl group. The permeability coefficient of Ac(NMef)3NHMe, with four methyl groups, was 10-fold greater than that of the smaller peptide, AcfNH2, even though both peptides contain five hydrogen bonds. When compared with vertebrate membranes, transport of the model peptides across A. suum cuticle was about 10-fold slower. A biophysical model for transcuticular transport of peptides predicted that nematode FaRPs, which are larger, less methylated and less lipophilic than the model peptides tested, would not be absorbed across the cuticle of nematodes. This prediction was confirmed for the excitatory FaRP, AF2 (KHEYLRFamide), which did not diffuse across the cuticle/hypodermis complex, but diffused rapidly across lipid-extracted cuticle preparations.

Animals↗

Calibration of position and angular data from a magnetic tracking device.

This paper describes a method for calibrating data from a magnetic tracking device. Position and orientation data were collected in a 1. 6x0.8x1.4m(3) volume using a Polhemus Fastrak((R)) in conjunction with both a long-range and standard transmitter. Position and orientation data were calibrated using a locally linear model based on the position of the measurement. After calibration, the average position and angular errors were less than 1.8cm and 1.2 degrees up to 1.8m from the transmitter for the long-range transmitter. For the standard transmitter, even after calibration, errors increased sharply when the sensor was more than 1.2m from the transmitter. Up to that distance, post-calibration errors were less than 1.2cm and 1. 2 degrees, while up to 1.8m they were below 5cm and 4 degrees. These errors could be further reduced by noise filtering. However, use of the standard transmitter is not recommended at distance greater than 1.2m due to orientation-based effects. It was concluded that for the volume investigated, tracking devices could provide similar three-dimensional accuracy to video systems.

Calibration↗

Parallel plate model for trabecular bone exhibits volume fraction-dependent bias.

Unbiased stereological methods were used in conjunction with microcomputed tomographic (micro-CT) scans of human and animal bone to investigate errors created when the parallel plate model was used to calculate morphometric parameters. Bone samples were obtained from the human proximal tibia, canine distal femur, rat tail, and pig spine and scanned in a micro-CT scanner. Trabecular thickness, trabecular spacing, and trabecular number were calculated using the parallel plate model. Direct thickness, and spacing and connectivity density were calculated using unbiased three-dimensional methods. Both thickness and spacing calculated using the plate model were well correlated to the direct three-dimensional measures (r(2) = 0. 77-0.92). The correlation between trabecular number and connectivity density varied greatly (r(2) = 0.41-0.94). Whereas trabecular thickness was consistently underestimated using the plate model, trabecular spacing was underestimated at low volume fractions and overestimated at high volume fractions. Use of the plate model resulted in a volume-dependent bias in measures of thickness and spacing (p < 0.001). This was a result of the fact that samples of low volume fraction were much more "rod-like" than those of the higher volume fraction. Our findings indicate that the plate model provides biased results, especially when populations with different volume fractions are compared. Therefore, we recommend direct thickness measures when three-dimensional data sets are available.

Adolescent↗

Biophysical model for organic acid excretion in Ascaris suum.

To develop a model for the mechanisms of organic acid excretion in nematodes, we measured the concentrations of volatile fatty acids (VFAs), pH and electrical potentials across hypodermal and muscle membranes and across the composite body wall (consisting of hypodermis, muscle and cuticle) of Ascaris suum using standard chromatographic and microelectrode recording techniques. In incubates containing one parasite in 20 ml modified Ascaris Ringer's solution, the level of combined VFAs excreted into the medium increased linearly for about 18 h, then plateaued at a concentration of 4.2 mM; the medium acidified rapidly to a plateau at about pH 5.0 within 4-6 h. Following 24 h incubations, the concentrations of VFAs in the hypodermis, muscle, and pseudocoelomic compartments were 62.4 +/- 8.1, 62.3 +/- 7.8 and 74.4 +/- 3.2 mM, respectively. The pseudocoelomic fluid was more acidic (pH 6.52 +/- 0.06) than the hypodermis (pH 6.78 +/- 0.03) or muscle (pH 6.77 +/- 0.03). These data and the electrical potentials across hypodermal (-57.9 +/- 6.3 mV) and muscle (-30.3 +/- 0.8 mV) membranes were used to determine the equilibrium concentrations for protonated (HVFA) and anionic (VFA-) forms of the acids across these membranes and across the cuticle. Under these conditions, little transmembrane or transmural excretion of HVFAs is expected to occur in A. suum. However, a 16-27 mV driving force for VFA- excretion exists across hypodermal and muscle membranes, and a larger driving force is predicted to exist for these anions across the cuticle. This driving force could provide potential energy for VFA- excretion through anion channels which exist in muscle and hypodermal membranes of this parasite, or for facilitated transport systems.

Animals↗

Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis.

The suitability of a long-range transmitter was evaluated for use with a Polhemus Fastrak magnetic tracking device in kinesiologic studies. Performance was judged by comparing positional and rotational accuracy to a standard transmitter. Data were obtained at distances of up to 2.7 and 5.0 m for the standard and long-range transmitters, respectively. Use of the long-range transmitter improved system performance allowing reproducible measurements at a greater distance. However, it is necessary to calibrate the system in each new test environment as there can be significant distortion of the magnetic field.

Artifacts↗

Influence of organic acid excretion on cuticle pH and drug absorption by Haemonchus contortus.

To determine if a cuticle microenvironment pH is maintained by adult Haemonchus contortus, organic acid excretion kinetics and absorption kinetics of selected model weak acids and a weak base were measured in incubation media that varied in buffer capacity (0.25-20 mM HEPES or 5 mM glycine) and initial pH (7.5 or 3.5). To evaluate the importance of the cuticle as a pathway for organic acid excretion and drug absorption the pharynx was paralyzed with 1 nM ivermectin. H. contortus changed the media pH from initial values of 7.5 or 3.25 to an asymptotic value of approximately 5.6. The rate of pH change depended on the buffer capacity, but was not affected by chemical ligation with ivermectin. The intrinsic rate of excretion of organic acids (0.045 +/- 0.016 micromol/cm2 x h) was constant during the first 8-12 h of incubation and was independent of initial pH, buffer capacity or ivermectin ligation. The rates of absorption of the model weak acids, benzoic acid and p-nitrophenol, and the model weak base, aniline, were not affected by initial pH, buffer capacity or ivermectin ligation. These results suggest that H. contortus excretes organic acid endproducts of carbohydrate metabolism across its cuticle, and that these acids maintain a microenvironment pH within the water-filled pores of the cuticle that controls the rate of adsorption of weakly acidic or basic drugs.

Absorption↗

Theoretical perspectives on anthelmintic drug discovery: interplay of transport kinetics, physicochemical properties, and in vitro activity of anthelmintic drugs.

This multidisciplinary study demonstrates the utility of the biophysical model approach to assess biological activity of anthelmintics in light of drug-delivery principles. The relationships between drug absorption and efficacy for a set of structurally disparate anthelmintics were determined in cultures of Haemonchus contortus, a nematode that parasitizes the ruminant gastrointestinal tract. Uptake, parameterized by the permeability coefficient, Pe, was shown to occur by absorption across the cuticle. Rates of drug appearance in nematode carcasses paralleled rates of drug disappearance from the medium, and absorption reached an apparent equilibrium within a few hours. The parasite/medium partition coefficient, K, was derived from the ratio of drug concentration in the parasite vs the medium at equilibrium. Pe and K values for each anthelmintic were correlated with lipophilicity (as measured by the partition coefficient (PC) in n-octanol/water) and both parameters plateaued at log PC approximately 2.5, with maximum Pe approximately 8 x 10(-4) cm/min and log K < or = 2.0. Absorption kinetics were related to in vitro potency by monitoring motility of H. contortus. The time required to reduce motility by 50% (t* 50) and Pe were used to calculate Cn*, the drug concentration in the parasite at t* 50, as an indicator of intrinsic potency. The quantitative interplay of apparent biological activity expressed as t* 50, dose, and intrinsic potency highlights the important contribution of drug-uptake kinetics.

Absorption↗