Plain radiographic interpretation in trimalleolar ankle fractures poorly assesses posterior fragment size.

Twenty-five patients with trimalleolar ankle fractures were evaluated using both conventional radiography and computed tomography (CT) to determine the size of the posterior fragment along with other fracture characteristics. Plain radiograph measurements indicated very poor inter- and intraexaminer reliability. When compared to the CT scan measurement, 54% of the plain radiographic readings revealed > 25% error. Plain radiographic interpretations erred in most cases by overrating the size of the fragment, but major underestimations also occurred. The larger size fragments showed more error than the smaller ones. This information confirms our clinical suspicion that the lateral radiograph is unreliable in assessing the posterior fragment size.

Ankle Injuries↗

The reduction clamp: a simple device for closed reduction during intramedullary nailing.

Reduction of femoral shaft fractures prior to passing the guide pin during intramedullary fixation may be a challenging problem, especially in delayed reductions or obese patients. We describe a simple and useful instrument for obtaining and maintaining reduction for closed intramedullary fixation. It provides a three-point fixation that may be locked into position to maintain the reduction. The surgeon is not required to hold the device in position while passing the guide pin, the reamer, or the nail. It frees the surgeon's hands, minimizes the need for an assistant, and reduces harmful x-ray exposure to the hands.

Femoral Fractures↗

Optimizing bone screw pullout force.

Stability of internal fixation by plate and screw depends on the interface of bone and screw threads. Bone-screw thread design was tested in a synthetic bone model to determine maximum bone-screw pullout force. The model was confirmed to provide reproducible results in a clinically relevant range. Consistent material properties were reflected in the relatively small standard deviations in pullout force, which were less than 10% of mean values. As expected, major diameter was an important determinant of pullout force in a roughly linear manner. Pitch was important with a finer thread giving greater purchase. Minor diameter and the ratio of major to minor diameter had a small but significant effect on pullout force. This study was significant for establishing a good bone-screw testing model and suggesting important thread parameters in selecting or manufacturing a bone screw to optimize its holding power.

Biomechanical Phenomena↗