PubMed Health⌕ Search

Biomedical subjects

J S Forrester

Publications and source records attributed to J S Forrester.

At least 37 records · Page 2Linked to original sources

Effects of clopidogrel, aspirin and combined therapy in a porcine ex vivo model of high-shear induced stent thrombosis.

AIMS: Use of ticlopidine in coronary stenting is limited by delayed onset of action. We studied the effects of clopidogrel, a rapidly acting analog of ticlopidine alone, and in combination with aspirin, in inhibiting stent thrombosis. METHODS: Unpolished nitinol stents were deployed in a porcine ex vivo arteriovenous shunt and exposed to flowing arterial blood at a shear rate of approximately 1500. s-1. Stent thrombus, platelet aggregation and bleeding times were measured at baseline and after treatment. RESULTS: Intravenous clopidogrel produced a rapid (within 30 min) and dose-dependent inhibition of stent thrombosis, with 87% reduction at a dose of 10 mg.kg-1 (P < 0.001). Aspirin alone (10 mg.kg-1) was minimally effective (20% inhibition P > 0.05) in inhibiting stent thrombosis. Combined treatment with clopidogrel and aspirin produced 95-98% inhibition of stent thrombosis, even at low doses of clopidogrel (2.5-5.0 mg.kg-1) (P < 0.0001). At effective doses both clopidogrel and combined therapy produced significant prolongation of bleeding time (P < 0.05) and inhibition of platelet aggregation (P < 0.05). CONCLUSION: Clopidogrel, either alone or combined with aspirin, may have a potential role in preventing stent thrombosis in high-risk clinical situations.

Animals↗

Aortic smooth muscle cells interact with tenascin-C through its fibrinogen-like domain.

The extracellular matrix protein tenascin-C is a multidomain protein that regulates cell adhesion. We used two different smooth muscle cell subtypes derived from adult and newborn rat aorta to investigate the interaction of tenascin-C or its various domains with these cells using an adhesion assay. Newborn cells were three times more adherent to tenascin-C than adult cells. Tenascin C-adhering cells remained round, whereas they spread rapidly on a fibronectin substrate. Adhesion assays showed the interaction between tenascin-C and newborn cells to be predominantly RGD-independent. Mg2+ increased newborn cell adhesion to tenascin-C in a concentration-dependent manner, whereas Ca2+ had no effect. To analyze the structure-function relationships of different domains of tenascin-C, we used recombinant full-length fibronectin-like and fibrinogen-like domains and various subdomains corresponding to the alternatively spliced regions of tenascin-C. The cells adhered to the fibrinogen-like domain but not to the fibronectin-like domain or its subdomains. As with the intact tenascin-C molecule, adherent cells remained round, and the Mg2+, but not Ca2+, promoted this interaction. The interaction of cells with the fibrinogen-like region was further mapped to a 30-amino acid peptide located near the carboxyl-terminal part of the tenascin-C molecule. The same 30-amino acid peptide was active in promoting cell migration. Our results provide a basis for understanding the mechanism of interaction of tenascin-C with smooth muscle cells and a framework for isolating membrane binding sites that mediate the cellular responses to this molecule.

Amino Acid Sequence↗

Lipid lowering versus revascularization: an idea whose time (for testing) has come.

There is strong evidence that revascularization does not prevent myocardial infarction in patients with stable coronary artery disease (CAD). The anatomic basis for this counterintuitive conclusion seems to be that most myocardial infarctions occur at sites that did not previously exhibit an angiographically significant stenosis. These angiographic observations are further supported by thallium studies in stable CAD that demonstrate that the site of stress-induced ischemia is frequently not the site of subsequent myocardial infarction. Since both coronary artery bypass graft surgery and percutaneous transluminal coronary angioplasty are directed at more severe coronary stenoses, we are led to the remarkable conclusion that angiography does not identify, and consequently revascularization therapies do not treat, the lesions that lead to myocardial infarction. The pathology of coronary atherosclerosis provides the basis for understanding why revascularization does not prevent infarction: unstable lesions that cause infarction are not necessarily severely stenotic, and stenotic lesions are not necessarily unstable. In contrast to revascularization, lipid lowering reduces the rate of myocardial infarction by approximately 30% over a period of 5 years. Thus, we might postulate that lipid lowering is the more effective therapy for both prevention of acute myocardial infarction and long-term survival. The health policy and economic implications of this viewpoint, should it emerge in the management of coronary heart disease, are clearly substantial. Consequently, the relative roles of lipid-lowering therapy and revascularization, both alone and together, must now be determined. It is an idea whose time--for testing--has come.

Angioplasty, Balloon, Coronary↗

Using serum cholesterol as a screening test for preventing coronary heart disease: the five fundamental flaws of the American College of Physicians Guidelines.

The guidelines ignore the common catastrophic first presentation of coronary disease, the powerful predictive value of serum cholesterol in young persons, the effectiveness of cholesterol-lowering interventions, the low cost of effective dietary modification, and the effectiveness of lipid lowering in women and in the elderly.

Aged↗

Effects of GP IIb/IIIa receptor monoclonal antibody (7E3), heparin, and aspirin in an ex vivo canine arteriovenous shunt model of stent thrombosis.

BACKGROUND: Thrombosis is an important limitation of metallic coronary stents, especially in smaller vessels in which shear rates are high. Monoclonal antibody to platelet glycoprotein IIb/IIIa receptor (7E3) has been shown to inhibit shear-induced platelet aggregation. In this study, we compared the effects of 7E3, heparin, and aspirin on stent thrombosis in an ex vivo arteriovenous shunt model of high-shear blood flow. METHODS AND RESULTS: An ex vivo arteriovenous shunt was created in 10 anesthetized dogs. Control rough-surface slotted-tube nitinol stents (n = 72) expanded to 2 mm in diameter in a tubular perfusion chamber were interposed in the shunt and exposed to flowing arterial blood at a shear rate of 2100s-1 for 20 minutes. The animals were treated with intravenous murine 7E3 (Fab')2 (0.2, 0.4, and 0.8 mg/kg), heparin (100 U/kg), or aspirin (10 mg/kg). Effects of the test agents on thrombus weight, platelet aggregation, platelet P-selectin expression, bleeding time, and activated clotting time (ACT) were quantified. 7E3 reduced stent thrombosis by 95% (20 +/- 1 to 1 +/- 1 mg, P < .001) and platelet aggregation by 94% (14 +/- 2 to 1 +/- 1 omega, P < .001) at the highest dose (0.8 mg/kg). 7E3 significantly prolonged bleeding time but had no effect on ACT and platelet P-selectin expression. Heparin prolonged ACT but had no significant effect on stent thrombosis or platelet aggregation. Aspirin, although it inhibited platelet aggregation by 65%, had no effect on stent thrombosis (19 +/- 2 versus 20 +/- 1 mg in controls). CONCLUSIONS: 7E3 produced a dose-dependent inhibition of acute stent thrombosis under high-shear flow conditions. Stent thrombosis was resistant to heparin and aspirin. Thus, 7E3 may be an effective agent for preventing stent thrombosis.

Abciximab↗

Sustained local drug delivery to the arterial wall via biodegradable microspheres.

This study was designed to evaluate the feasibility of applying locally delivered polylactic acid microspheres for drug delivery to the arterial wall. To study drug persistence, rhodamine-loaded microspheres were infused into one carotid artery of 14 rabbits and plain rhodamine solution into the other by using a porous balloon. To study tissue response, plain microspheres and dexamethasone-loaded microspheres were infused into the carotid arteries of another group of rabbits. To study the antiproliferative effects of locally delivered drug, 20 rabbits were subjected to overstretch balloon injury to both carotid arteries and divided into 4 groups: injury alone, plain microspheres, dexamethasone-loaded microspheres, and microspheres containing colchicine and dexamethasone. Fluorescent microspheres persisted in the vessel wall for 4 wk, whereas rhodamine without microspheres disappeared at 72 h. Histopathologic studies in arteries infused with unloaded microspheres showed inflammatory cell infiltrate with polymorphonuclear cells at 1 wk and macrophages and giant cells at 4 wk. Arteries infused with dexamethasone-loaded microspheres did not show any inflammatory cell infiltrate. Local delivery of dexamethasone or dexamethasone plus colchicine did not result in significant change in the intima-to-media ratio or in residual lumen following balloon injury. Polylactic acid microspheres may be used for prolonged delivery of drugs or other bioactive agents locally to the arterial wall. They induce an inflammatory reaction that is suppressable by dexamethasone in the microspheres. Dexamethasone or dexamethasone and colchicine delivered via this system, however, failed to reduce the degree of intimal hyperplasia after overstretch balloon injury to the rabbit carotid arteries.

Angioplasty, Balloon, Coronary↗

The secondary prevention of coronary artery disease.

Randomized clinical trials demonstrate the efficacy of medical secondary prevention in coronary disease patients. The magnitude of risk reduction with exercise, diet, lipid modification, and smoking cessation is similar to other medical therapies for coronary disease such as aspirin, beta blockers, as well as coronary bypass surgery, (Table VI) In contrast to these therapies, however, secondary prevention stabilizes angiographic progression in about 50% of patients and induces regression in about 25% of patients. Both symptoms and perceived quality of life also are beneficially altered by secondary prevention programs, although possibly not by the magnitude reported for bypass surgery. These clinical trial results have led the American Heart Association, and the American College of Cardiology to strongly endorse secondary prevention. A reasonable projection based on these clinical trial data is that widespread use of these recommendations in the 12 million established coronary disease patients would significantly reduce coronary mortality and morbidity.

Coronary Disease↗

Dissolution of thrombotic arterial occlusion by high intensity, low frequency ultrasound and dodecafluoropentane emulsion: an in vitro and in vivo study.

OBJECTIVES: We examined the effectiveness of the microbubbles of an echo contrast agent, dodecafluoropentane (DDFP) emulsion, to enhance low frequency ultrasound clot disruption in vitro and in vivo. BACKGROUND: Ultrasound is reported to facilitate clot dissolution, and microbubbles could theoretically enhance ultrasound clot dissolution by augmenting cavitational effects. METHODS IN VITRO STUDIES: The disruption rate of fresh human clots by ultrasound (24 kHz, 2.9 W/cm2) was examined in saline and DDFP emulsion. In vivo studies: Using a rabbit iliofemoral thrombotic occlusion model, recanalization rate and histopathologic findings were compared among groups treated with DDFP emulsion alone, transcutaneous ultrasound (20 kHz, 1.5 W/cm2) alone and with DDFP emulsion and ultrasound combined. RESULTS: The ultrasound clot disruption rate was significantly (p < 0.01) increased, from 72 +/- 18% (mean +/- SD) in saline to 98 +/- 4% in DDFP emulsion in 3 min in vitro. No vessel was recanalized by DDFP emulsion alone (0%), and only a single artery was patent after ultrasound treatment alone (9%). In contrast, 82% of iliofemoral arteries were angiographically recanalized after ultrasound treatment with DDFP emulsion. Histologically, the patent arteries had only minimal focal mural thrombus, with no evidence of vessel wall damage. However, substantial damage was observed in rabbit dermis and subcutaneous tissue. CONCLUSIONS: 1) DDFP emulsion, an echo contrast agent, significantly enhances the clot-disrupting effect of low frequency ultrasound in vitro and in an in vivo rabbit iliofemoral occlusion model. 2) This simple combination therapy has potential for clinical application in patients with thrombotic arterial occlusions.

Animals↗

Inhibition of acute stent thrombosis under high-shear flow conditions by a nitric oxide donor, DMHD/NO. An ex vivo porcine arteriovenous shunt study.

BACKGROUND: Coronary stenting is limited by subacute thrombosis, especially in smaller-diameter vessels, in which shear rates are high. The objective of the present study was to determine whether local delivery of a new type of NO donor, the NO adduct of N,N'-dimethylhexanediamine (DMHD/NO), inhibits acute stent thrombosis (ST) at high-shear flow. METHODS AND RESULTS: Effects of local infusion of DMHD/NO; intravenous aspirin, and heparin on ST were evaluated in an ex vivo porcine AV shunt model. Nitinol stents (2 mum in diameter, n = 120) were placed in a tubular chamber and perfused with blood from pigs (n = 13) at a shear rate of 2100s-1 for 20 minutes. ST was quantified by measurement of dry thrombus weight(TW). Effects on platelet aggregation (PA), blood pressure, bleeding time, and activated clotting time (ACT) were also examined. There was a dose-dependent inhibition of ST and PA by DMHD/NO. TW was reduced by 95% (1 +/- 2 versus 16 +/- 4 mg control, mean +/- SD, P < .001), and PA was reduced by 75% (4 +/- 3 versus 14 +/- 9 omega/min control, P < .05) at the highest dose of 10 mumol/L. DMHD/NO had no effects on bleeding time, ACT, or blood pressure. In contrast, aspirin (10 mg/kg), despite inhibiting PA, had no effects on TW (12 +/- 5 versus 16 +/- 8 mg control, P = .3). Heparin (200 U/kg) reduced TW by 33% (14 +/- 4 versus 21 +/- 3 mg control, P < .05) and prolonged ACT. CONCLUSIONS: Local delivery of DMHD/NO produced a 15-fold inhibition of acute ST at high-shear flow without producing adverse systemic hemostatic or hemodynamic effects. Thus, treatment with DMHD/NO may be an effective strategy for prevention of stent thrombosis.

Animals↗

Subacute thrombosis and vascular injury resulting from slotted-tube nitinol and stainless steel stents in a rabbit carotid artery model.

BACKGROUND: Our objectives were to quantify the thrombogenicity and extent of vascular injury created by slotted-tube geometry stainless steel and nitinol coronary stents in a rabbit carotid artery model. METHODS AND RESULTS: Stents were implanted in rabbit right carotid arteries without antiplatelet therapy. Stainless steel stents were implanted for 4 days while nitinol stents were placed for 4 and 14 days (n = 8, 8, and 6, respectively). Stent thrombosis was assessed by thrombus weight, grading thrombus encroachment of the lumen, and by blood flow in the stented and contralateral arteries. Stainless steel stents at 4 days contained more thrombus than 4- and 14-day nitinol stents (20.0 +/- 5.9 versus 2.5 +/- 0.6 and 2.7 +/- 0.3 mg, respectively; P < .000001). Stainless steel stents were more often occluded by thrombus (6 of 8) or contained more subocclusive thrombus (2 of 8) than nitinol stents (0 of 14, P < .002). Resting blood flow was reduced in arteries with stainless steel stents compared with 4- and 14-day nitinol stents (1.5 +/- 2.8 versus 24.0 +/- 2.0 and 25.5 +/- 1.9 mL/min, respectively, P < .000001). Stainless steel stents were less uniformly expanded, had deeper strut penetration into the vascular wall, and were associated with more extensive medial smooth muscle cell necrosis. There were strong correlations (r = .77 to .95) between variables of thrombosis extent (thrombus weight and grade) and histologically determined vascular injury (strut penetration and medial necrosis). CONCLUSIONS: Slotted-tube stainless steel stents were more thrombogenic and created more extensive vascular injury than nitinol stents in a rabbit carotid artery model. The mechanisms underlying these differences probably are related to metallurgic and design geometry properties of the two stent types.

Acute Disease↗

Transcutaneous ultrasound augments lysis of arterial thrombi in vivo.

BACKGROUND: External ultrasound has a synergistic effect on thrombus disruption with thrombolytic agents in vitro. We hypothesized that transcutaneous ultrasound could augment thrombolysis in vivo. METHOD AND RESULTS: Thrombus formation was induced electrically in 48 pairs of iliofemoral arteries of 24 rabbits; arterial occlusions were documented angiographically. In 17 of 24 rabbits, 25000 units/kg streptokinase was then administered intravenously. The pairs of iliofemoral arteries were randomized to receive ultrasound treatment or no ultrasound treatment. Low-frequency (26 kHz) ultrasound (continuous wave, 18 W/cm2) was applied transcutaneously over the area of occlusion. In 7 of 24 rabbits, 14 thrombotically occluded iliofemoral arteries were exposed to ultrasound alone without streptokinase. The results were evaluated through the use of angiography (TIMI grade flow) and histopathology. After 30 +/- 10 minutes of activated sonication combined with intravenous streptokinase, 10 of 17 iliofemoral arteries (59%) treated with transcutaneous ultrasound were widely patent angiographically, with TIMI grade 3 flow. Histologically, the patent arteries had only minimal focal moral thrombus. The angiographic patency rate was significantly lower in the control groups: 1 of 17 arteries (6%) treated with streptokinase alone (P = .0012) and 1 of 14 arteries (7%) treated with ultrasound alone (P = .0036). CONCLUSIONS: In vivo transcutaneous ultrasound significantly augments lysis of thrombi with streptokinase in rabbit iliofemoral arteries.

Angiography↗

Coronary artery restenosis after balloon angioplasty in humans is associated with circumferential coronary constriction.

Therapies that inhibit intimal hyperplasia do not prevent restenosis after coronary artery balloon angioplasty, suggesting that additional mechanisms may be responsible for restenosis in humans. Using an intravascular ultrasound (Hewlett-Packard Sonos Intravascular Imaging System). 3.5F, 30-MHz (Boston Scientific) monorail imaging catheter, we studied 17 patients with clinical and angiographic restenosis at an average (mean +/- SD) of 7 +/- 6 months after balloon angioplasty (13 men age, 71 +/- 10 years; 12 left anterior descending coronary arteries, 4 right coronary arteries, and 1 left circumflex coronary artery) The lumen area (L.A), vessel wall area (VWA), and total cross-sectional area (CSA) within the external elastic lamina were measured at the restenosis site and at proximal and distal reference sites, which were defined as adjacent segments with the least amount of plaque. Consistent with coronary angiography findings, decreased LA at the restenotic site was detected in all 17 patients. The unique finding was that total CSA at the restenotic site was significantly decreased compared with both proximal and distal reference sites (10.1 +/- 2.4 versus 14.8 +/- 3.2 mm2 and 10.1 +/- 2.4 versus 13.8 +/- 3.1 mm2, respectively, P < .001), whereas VWA (intima plus media) was slightly increased at the angioplasty site compared with both proximal and distal reference sites (8.0 +/- 2.3 versus 7.6 +/- 2.3 mm2 and 8.0 +/- 2.3 versus 6.7 +/- 2.3 mm2, respectively, P = NS). Eighty-three percent of the loss in LA at the restenotic site was due to constriction of the total CSA, while the increase in VWA at the restenotic site accounted for only a 17% loss in LA. We then compared these results with the morphology of coronary artery segments in 14 patients without restenosis. These coronary artery segments had been previously treated with balloon angioplasty (7 +/- 5 months). Unlike that in restenotic lesions, the total CSA within the external elastic lamina at the sites of previous angioplasty was similar to that in distal and proximal reference sites (P = NS). Significant and consistent reduction in arterial CSA, with a minor increase in VWA, characterizes human coronary lesions that cause angiographic restenosis. These data suggest that in humans, "recoil" and/or vascular contraction with healing in response to balloon injury is a major contributor to restenosis after balloon angioplasty.

Aged↗