PubMed HealthSearch

Biomedical subjects

J S Gati

Publications and source records attributed to J S Gati.

11 recordsLinked to original sources

Dissociating pain from its anticipation in the human brain.

The experience of pain is subjectively different from the fear and anxiety caused by threats of pain. Functional magnetic resonance imaging in healthy humans was applied to dissociate neural activation patterns associated with acute pain and its anticipation. Expectation of pain activated sites within the medial frontal lobe, insular cortex, and cerebellum distinct from, but close to, locations mediating pain experience itself. Anticipation of pain can in its own right cause mood changes and behavioral adaptations that exacerbate the suffering experienced by chronic pain patients. Selective manipulations of activity at these sites may offer therapeutic possibilities for treating chronic pain.

Adult

Repetition priming and the time course of object recognition: an fMRI study.

We investigated the effects of repetition priming on the time course of recognition in several visual areas of the brain using fMRI. We slowed down recognition by gradually revealing the stimuli, in order to prolong the pre-recognition phase. Activation was lower for primed than for non-primed objects overall in both the occipitotemporal region (OTR) and the intraparietal region (IPR). A difference was found between primed and non-primed objects in the rate of increase of OTR activation. We concluded that the IPR, in addition to the OTR, was affected by repetition priming, and that this effect was different from that seen in the OTR.

Adult

Imaging of current density and current pathways in rabbit brain during transcranial electrostimulation.

A magnetic resonance imaging (MRI) method was used for a noninvasive study of current density (CD) and current pathways (CP's) inside the skull during transcranial electrostimulation in rabbits. The transcranial impulse current directions studied were those previously used in transcranial electric treatment either sagittally or bilaterally. MRI data were collected from slices perpendicular to the direction of current application. In these slices, only the perpendicular component of the CD was measured. Computer methods for accurate topographic mapping of the main areas with high CD and for reconstruction of CP's are described. It was revealed that current applied on the head sagittally passed mostly through the cerebrospinal fluid in the basal brain cisternas connected in series, and through the anterior horns of the lateral ventricles, foramina of Monro, ventrocaudal part of the third ventricle, aqueductus, and fourth ventricle. Possible connections between these CP's are suggested. Bilaterally applied current passed through the brain and skull core more diffusely without concentrations in cisternas and ventricles. The results of the present study suggest an explanation for the observation that sagittally applied current more effectively stimulates brain structures with antinociceptive function and elicits more pronounced analgesic effect.

Animals

Recovery of fMRI activation in motion area MT following storage of the motion aftereffect.

We used functional magnetic resonance imaging (fMRI) during storage of the motion aftereffect (MAE) to examine the relationship between motion perception and neural activity in the human cortical motion complex MT+ (including area MT and adjacent motion-selective cortex). MT+ responds not only to physical motion but also to illusory motion, as in the MAE when subjects who have adapted to continuous motion report that a subsequent stationary test stimulus appears to move in the opposite direction. In the phenomenon of storage, the total decay time of the MAE is extended by inserting a dark period between adaptation and test phases. That is, when the static test pattern is presented after a storage period equal in duration to the normal MAE, the illusory motion reappears for almost as long as the original effect despite the delay. We examined fMRI activation in MT+ during and after storage. Seven subjects viewed continuous motion, followed either by an undelayed stationary test (immediate MAE) or by a completely dark storage interval preceding the test (stored MAE). Like the perceptual effect, activity in MT+ dropped during the storage interval then rebounded to reach a level much higher than after the same delay without storage. Although MT+ activity was slightly enhanced during the storage period following adaptation to continuous motion (compared with a control sequence in which the adaptation grating oscillated and no MAE was perceived), this enhancement was much less than that observed during the perceptual phenomenon. These results indicate that following adaptation, activity in MT+ is pronounced only with the presentation of an appropriate visual stimulus, during which the MAE is perceived.

Figural Aftereffect

Reduced visual evoked responses in multiple sclerosis patients with optic neuritis: comparison of functional magnetic resonance imaging and visual evoked potentials.

The limited application of functional magnetic resonance imaging (fMRI) for investigations of multiple sclerosis (MS) patients has already shown that deficits of the motor, cognitive and visual systems may be identified by differences in the patterns of activation in response to a suitable stimulus. In MS patients with unilateral optic neuritis, the area of activation in the primary visual cortex, measured by fMRI techniques, is dramatically reduced in response to stimulation of the affected eye. The latency of the major positive component of the visual evoked potential (VEP) recorded upon stimulation of the affected eye is significantly increased in these patients, as compared to the unaffected eye and normal volunteers. We have found a correlation between the neural response measured using fMRI and the latency of the VEP. fMRI signal responses have the potential to provide more detailed topographic information relating to functional deficits in MS.

Evoked Potentials, Visual

Mental chronometry using latency-resolved functional MRI.

Vascular responses to neural activity are exploited as the basis of a number of brain imaging techniques. The vascular response is thought to be too slow to resolve the temporal sequence of events involved in cognitive tasks, and hence, imaging studies of mental chronometry have relied on techniques such as the evoked potential. Using rapid functional MRI (fMRI) of single trials of two simple behavioral tasks, we demonstrate that while the microvascular response to the onset of neural activity is delayed consistently by several seconds, the relative timing between the onset of the fMRI responses in different brain areas appears preserved. We examined a number of parameters that characterize the fMRI response and determined that its onset time is best defined by the inflection point from the resting baseline. We have found that fMRI onset latencies determined in this manner correlate well with independently measurable parameters of the tasks such as reaction time or stimulus presentation time and can be used to determine the origin of processing delays during cognitive or perceptual tasks with a temporal accuracy of tens of milliseconds and spatial resolution of millimeters.

Brain

Spatial and temporal resolution of functional magnetic resonance imaging.

Functional magnetic resonance imaging has become an invaluable tool for cognitive neuroscience, despite the fact that many of the physiological mechanisms giving rise to the effect are not well understood. We review the known biochemical and physiological basis of the technique and discuss how, within the noted limits, one might fully exploit the spatial and temporal resolution that is intrinsic to the very high magnetic fields that we use for human studies. This noninvasive brain mapping technique relies on the changes in blood oxygenation, blood volume, and blood flow, and we discuss some of the issues influencing the effects of these hemodynamic parameters on image intensity.

Anaerobiosis

Differences in perceived shape from shading correlate with activity in early visual areas.

The perception of shape from shading depends on the orientation of the shading gradient [1] [2] [3] [4]. Displays composed of elements with vertically oriented shading gradients of opposite polarity produce a strong and stable percept of 'concave' and 'convex' elements. If the shading gradients are rotated 90 degrees , the depth percept is reduced and appears much more ambiguous. Results from psychophysical [1] [2] [3] [4] [5] [6], neuropsychological [7] and computational studies [8] [9] suggest that the perception of shape from shading engages specific mechanisms in early cortical visual areas. In a three-dimensional functional magnetic resonance imaging (fMRI) study at 1.5 Tesla using a three-dimensional, interleaved-echoplanar imaging technique and a surface radio frequency (RF) coil placed under the visual cortex, we investigated the activity in these early visual areas associated with viewing shape from shading displays at two different orientations. We found significantly greater activation in area V1 and neighbouring low-level visual areas of cortex when subjects viewed displays that led to weak and unstable depth percepts than when they viewed displays that led to strong and stable depth percepts.

Adult

The functional scout image: immediate mapping of cortical function at 4 Tesla using receiver phase cycling.

A rapid method of generating functional scout images to map cortical activity is presented. Maps were produced immediately "on-line" on the scanner's console using fast low-angle shot gradient-recalled echo and echo-planar imaging sequences without special hardware. To demonstrate the technique, raw data collected during photic stimulation and dark control periods were subtracted through phase alternation of the receiver with constant transmitted radio frequency phase. A blood oxygen level-dependent signal difference map was produced by magnitude reconstruction of the resulting complex-difference data. Maps improved in contrast with an increasing number of stimulation-control cycles and showed similar areas of activation to traditional fMRI processing methods. Such a functional scout procedure allows rapid localization of brain function within the anatomical region of interest. From these functional scout images, slices or voxels may be planned by using the scanner manufacturers prescription tools for further specialized studies.

Brain Mapping

Experimental determination of the BOLD field strength dependence in vessels and tissue.

High resolution functional MRI (fMRI) experiments were performed in human visual cortex at 0.5, 1.5, and 4 T to determine the blood oxygenation level dependent (BOLD) field strength response within regions of obvious venous vessels and cortical gray matter ("tissue"). T2*-weighted FLASH images were collected in single- and multi-echo mode and used to determine the intrinsic BOLD parameters, namely, signal-to-noise ratio (psi), the apparent transverse relaxation rate (R2*) and the change in R2* (deltaR2*) between the activated and baseline states. The authors find the average percentage signal change (deltaS/S, measured at TE = T2*) to be large in vessels (13.3 +/- 2.3%, 18.4 +/- 4.0%, and 15.1 +/- 1.2%) compared with that in tissue (1.4 +/- 0.7%, 1.9 +/- 0.7%, and 3.3 +/- 0.2%) at 0.5, 1.5, and 4 T, respectively. The signal-to-noise ratio in optimized, fully relaxed proton density weighted gradient echo images was found to increase linearly with respect to the static magnetic field strength (B0). The predicted upper bound on BOLD contrast-to-noise ratio (deltaS/R)max as a function of field strength was calculated and found to behave less than linearly in voxels containing vessels larger than the voxel itself and greater than linearly in voxels containing a mixture of capillaries and veins/venules with a diameter less than that of the voxel.

Humans

Investigation of BOLD contrast in fMRI using multi-shot EPI.

High resolution volume coverage of the brain in fMRI studies can be accomplished using multi-slice, multi-shot EPI. We demonstrate that the optimum contrast sensitivity in BOLD based fMRI experiments using multi-shot EPI is achieved by using the shortest possible TR values between segments and the longest tolerable echo train length. For a fixed paradigm time, acquiring the largest number of images under these conditions yields the best statistical detection thresholds. For a multi-slice multi-shot EPI fMRI study, the best approach is to perform the acquisition of all the segments in a single slice before continuing on to each of the slices in turn. Our results regarding the number of shots and TR are also applicable to other multi-shot techniques such as interleaved spirals.

Brain