PubMed Health⌕ Search

Biomedical subjects

J S Li

Publications and source records attributed to J S Li.

At least 19 recordsLinked to original sources

Ultra-thin TLDs for skin dose determination in high energy photon beams.

Estimation of surface dose is very important for patients undergoing radiation therapy. In this work we investigate the dose at the surface of a water phantom and at a depth of 0.007 cm, the practical reference depth for skin as recommended by ICRP and ICRU, with ultra-thin TLDs and Monte Carlo calculations. The calculations and measurements were carried out for fields ranging from 5 x 5 cm2 to 20 x 20 cm2 for 6 MV, 10 MV and 18 MV photon beams. The variation of the surface dose with angle of incidence and field size was investigated. Also, the exit dose was computed and measured for the same fields and angles of incidence. The dose at the ICRU reference depth was computed. Good agreement (+/-5%) was achieved between measurements and calculations. The surface dose at the entrance increased with the angle of incidence and/or the field size. The exit dose decreased with the angle of incidence but it increased with field size. The dose at the surface of the patient is mostly dependent on the beam energy, modality and beam obliquity rather than the field size and field separation. By correlating TLD measurements with Monte Carlo calculations, we were able to predict the dose at the skin surface with good accuracy. Knowing the dose received at the surface of the patient can lead to prediction of skin reactions helping with the design of new treatment techniques and alternative dose fractionation schemes.

Breast Neoplasms↗

Genetic analyses and mapping of a new thermo-sensitive genic male sterile gene in maize.

The present study describes a novel thermo-sensitive genic male sterile (TGMS) line, Qiong68ms. To analyse the mode of fertility inheritance and tag the TGMS gene, a set of F2, BC1 and F(2:3) populations derived from a cross between Qiong68ms and K12 were evaluated for a period of 2 years. Classical genetic analyses and QTL mapping using the mean restoration percentage of the F(2:3) populations revealed that the fertility of Qiong68ms was likely to be governed by a single recessive gene, which was named tms3; the tms3 gene was mapped to a location between SSR markers umc2129 and umc1041, at a distance of 3.7 cM form umc2129 and 1.5 cM form umc1041. The molecular markers tightly linked with tms3 gene will aid in the transfer of the TGMS gene to various background inbred lines using the MAS method.

Chromosome Mapping↗

Verapamil modulates LPS-induced cytokine production via inhibition of NF-kappa B activation in the liver.

OBJECTIVE: To investigate the effect of verapamil on Lipopolysaccharide (LPS)-induced cytokines [tumor necrosis factor-alpha (TNF-alpha), interleukin-6 (IL-6) and interleukin-10 (IL-10)] and nuclear factor kappa B (NF-kappa B) in the liver. METHODS AND MATERIALS: Adult male Sprague-Dawley rats were randomly divided into seven groups of eight rats each: control rats treated with saline (0.9 % NaCl); rats treated with saline and then challenged intraperitoneally with LPS (10 mg/kg); rats treated intraperitoneally with different levels of verapamil (1, 2.5, 5, 10 mg/kg) and then challenged with LPS (10 mg/kg); and rats treated only with verapamil (10 mg/kg). TNF-alpha, IL-6, IL-10 and NF-kappa B in the liver tissues were investigated as well as the serum levels of alanine aminotransferase (ALT) and aspartate aminotransferase (AST) one hour after LPS injection. RESULTS: LPS alone stimulated production of TNF-alpha, IL-6 and IL-10, and activated NF-kappa B in the liver. Pretreatment with verapamil before LPS challenge reduced acute liver injury, down-regulated production of LPS-induced pro-inflammatory cytokines (TNF-alpha and IL-6), up-regulated production of anti-inflammatory cytokines (IL-10) and inhibited NF-kappa B activation in the liver in a dose-dependent manner. CONCLUSION: Verapamil can attenuate acute liver injury by down-regulating the production of TNF-alpha and IL-6 and up-regulating IL-10 in the liver, possibly via inhibition of NF-kappa B.

Animals↗

A comparison of neonatal Gram-negative rod and Gram-positive cocci meningitis.

OBJECTIVE: Neonatal meningitis is an illness with potentially devastating consequences. Early identification of potential risk factors for Gram-negative rod (GNR) infections versus Gram-positive cocci (GPC) infection prior to obtaining final culture results is of value in order to appropriately guide expirical therapy. We sought to compare laboratory and clinical parameters of GNR and GPC meningitis in a cohort of term and premature infants. STUDY DESIGN: We evaluated lumbar punctures from neonates cared for at 150 neonatal intensive care units managed by the Pediatrix Medical Group Inc. We compared cerebrospinal fluid (CSF) parameters (white blood cell count, red blood cell count, glucose, and protein), demographics, and outcomes between infants with GNR and GPC meningitis. CSF cultures positive with coagulase-negative staphylococci were excluded. RESULTS: We identified 77 infants with GNR and 86 with GPC meningitis. There were no differences in gestational age, birth weight, infant sex, race, or rate of Caesarean section. GNR meningitis was more often diagnosed after the third postnatal day and was associated with higher white blood cell and red blood cell counts. GNR meningitis diagnosed in the first 3 days of life was associated with antepartum antibiotic exposure. No difference was noted in either CSF protein or glucose levels. After correcting for gestational age, there was no observed difference in mortality between infants infected with GNR or GPC. CONCLUSION: Compared to GPC meningitis, GNR meningitis was associated with several aspects of the clinical history and laboratory findings including older age of presentation, antepartum exposure to antibiotics, and elevated CSF white blood cell and red blood cell counts.

Anti-Bacterial Agents↗

Lack of association between ADAM33 gene and asthma in a Chinese population.

Asthma is a complex polygenic disease with gene-environment interactions being important. It has been previously suggested that ADAM33, which is a member of a gene family that encodes membrane-anchored proteins with a disintegrin and a metalloprotease domain, is primarily expressed in lung fibroblasts and bronchial smooth muscle cells and has been associated with airway remodelling and bronchial hyperresponsiveness. A significant association has previously been demonstrated between single nucleotide polymorphisms (SNPs) and haplotypes of the ADAM33 and asthma in ethnically diverse populations. To assess whether SNPs or haplotypes of ADAM33 are related to asthma in a Chinese Han population, we genotyped three SNPs of ADAM33 (7575G/A in intron 6, 11188A/T in intron 19, and 12433T/C in exon 20) in a case-control study involving 296 patients with asthma and 270 healthy controls. No significant association was detected between these three SNPs and asthma susceptibility in the Chinese population.

ADAM Proteins↗

Absence of association between two insertion/deletion coding genetic polymorphisms of TIM-1 gene and asthma in Chinese Han population.

TIM-1, a member of T-cell immunoglobulin domain and mucin domain (TIM) gene family, was implicated as an asthma susceptibility gene in previous studies. TIM-1 was expressed on CD4(+) T cells after activation and its expression was sustained preferentially in T-helper type 2 (T(H)2) but not in T(H)1 cells, therefore TIM-1 became a good candidate gene for atopic diseases. Recent studies indicated that two insertion/deletion (ins/del) coding genetic polymorphisms in exon 4 of TIM-1 were associated with asthma susceptibility in some but not in all populations. In order to investigate the relationship between TIM-1 genetic polymorphisms and asthma in Chinese Han population, we performed a case-control study for two insertion/deletion polymorphisms in TIM-1 exon 4 (5383_5397ins/del and 5509_5511delCAA) and a single nucleotide polymorphism (SNP) in intron 8 (IVS 8+9 G/A) between a healthy control group of 309 people and an asthma patient group of 352 people recruited from Chinese Han population. The polymorphisms were genotyped and the allele and genotype frequencies were analysed, but none of the three polymorphisms showed association with asthma susceptibility in single-locus association analyses. Linkage disequilibrium (LD) analyses demonstrated that the two insertion/deletion polymorphisms were in strong LD but the haplotypes constructed from these two polymorphisms showed no significant association with asthma. In conclusion, our findings suggest that 5383_5397ins/del, 5509_5511delCAA and SNP IVS 8+9 G/A polymorphisms are not associated with asthma susceptibility in Chinese Han population.

Adult↗

Effect of statistical uncertainties on Monte Carlo treatment planning.

This paper reviews the effect of statistical uncertainties on radiotherapy treatment planning using Monte Carlo simulations. We discuss issues related to the statistical analysis of Monte Carlo dose calculations for realistic clinical beams using various variance reduction or time saving techniques. We discuss the effect of statistical uncertainties on dose prescription and monitor unit calculation for conventional treatment and intensity-modulated radiotherapy (IMRT) based on Monte Carlo simulations. We show the effect of statistical uncertainties on beamlet dose calculation and plan optimization for IMRT and other advanced treatment techniques such as modulated electron radiotherapy (MERT). We provide practical guidelines for the clinical implementation of Monte Carlo treatment planning and show realistic examples of Monte Carlo based IMRT and MERT plans.

Computer Simulation↗

A particle track-repeating algorithm for proton beam dose calculation.

A particle track-repeating algorithm has been developed for proton beam dose calculation for radiotherapy. Monoenergetic protons with 250 MeV kinetic energy were simulated in an infinite water phantom using the GEANT3 Monte Carlo code. The changes in location, angle and energy for every transport step and the energy deposition along the track were recorded for the primary protons and all secondary particles. When calculating dose for a patient with a realistic proton beam, the pre-generated particle tracks were repeated in the patient geometry consisting of air, soft tissue and bone. The medium and density for each dose scoring voxel in the patient geometry were derived from patient CT data. The starting point, at which a proton track was repeated, was determined according to the incident proton energy. Thus, any protons with kinetic energy less than 250 MeV can be simulated. Based on the direction of the incident proton, the tracks were first rotated and for the subsequent steps, the scattering angles were simply repeated for air and soft tissue but adjusted properly based on the scattering power for bone. The particle step lengths were adjusted based on the density for air and soft tissue and also on the stopping powers for bone while keeping the energy deposition unchanged in each step. The difference in nuclear interactions and secondary particle generation between water and these materials was ignored. The algorithm has been validated by comparing the dose distributions in uniform water and layered heterogeneous phantoms with those calculated using the GEANT3 code for 120, 150, 180 and 250 MeV proton beams. The differences between them were within 2%. The new algorithm was about 13 times faster than the GEANT3 Monte Carlo code for a uniform phantom geometry and over 700 times faster for a heterogeneous phantom geometry.

Algorithms↗

Attention to the hiding iodine deficiency in pregnant and lactating women after universal salt iodization: A multi-community study in China.

BACKGROUND: Monitoring of iodine nutrition depends chiefly on the urinary iodine concentration in representative samples from the population. International groups have recommended school-age children as a convenient group for surveys, because of their accessibility and young age, but the relevance of this group to others, especially pregnant women, is not well established. OBJECTIVE: The purpose was to compare different approaches to assessing iodine nutrition within communities, especially for pregnant and lactating women. DESIGN: In an urban and a rural site from each of the 11 Chinese provinces, covering a wide geographic and socioeconomic range, we measured the iodine content of household salt and drinking water, the thyroid volume in school children, and the urinary iodine concentration in five population subsets; in some sites we also assessed iodine in breast milk and thyroid size in adult women. RESULTS: The median urinary iodine concentrations for pregnant and lactating women were well below those of the schoolchildren from the same community in most study sites, the difference between medians, at overall level, being about 50 microg/l for the pregnant and 40 microg/l for the lactating, respectively. When ranked by median urinary iodine concentrations at overall level, the order of the groups was: all infants, schoolchildren, women of childbearing age, lactating women and pregnant women in both urban and rural sites. This relative distribution was constant among the study sites. From it, we derived a relationship to predict the median values for other groups, based on the data of schoolchildren. The median iodine content of salt was 30.9 ppm in urban sites and 31.3 ppm in rural sites, respectively, close to the nationally mandated 35 mg/kg. Water had low iodine content (3.7 microg/l) in both urban and rural sites except in a rural site from Tianjin. Ultrasonography showed that 6.5% of 1329 children in urban sites and 5.3% of 1431 children in rural sites had thyroid enlargement. Breast milk had a median iodine content of 135.9 microg/l in the urban and 157.5 microg/l in the rural. The goiter prevalence by palpation was low (2.0%) among all women examined (3367), but higher in pregnant women (2.7%) than in lactating women or other adult women. CONCLUSIONS: An effective iodized salt program has brought iodine sufficiency to most of China, but pregnant women in some areas may still risk deficiency and need further supplements. We suggest other countries and international agencies pay more attention to pregnancy, where iodine deficiency has its worst consequences.

Adult↗

Microsurgical techniques in rat heterotopic small bowel transplantation: analysis of 450 cases.

BACKGROUND: We sought to review 450 rat small bowel transplantation (SBT) operations having a modified microsurgical technique to discuss the key steps for a successful operation. METHODS: Four hundred fifty rat heterotopic small bowel transplantations were performed in 3 stages: the first 80 cases were a training stage, the following 330 cases were for formal experiments, and, in the last stage, 40 cases were to analyze the relationship between the duration of cold preservation and recipient mortality. For all cases, revascularization of the graft was accomplished by an end-to-side anastomosis between the donor superior mesenteric artery or aorta and the recipient infra-renal aorta, and cuffed end-to-end anastomosis between the donor portal vein and the left renal vein of the recipient. The duration of each operation, graft warm ischemia time, and recipient survival rate were compared. RESULTS: In the first stage, the graft warm ischemia time was about 90 minutes where as it was only 35 minutes in the second stage. The longterm survival rates (>5 days) of recipients were 8.8% and 97.3%, respectively. In the 3rd stage, long cold preservation period significantly increased recipient mortality. CONCLUSIONS: Graft warm ischemia time was a key issue associated with recipient mortality; a well-trained, simplified microsurgical anastomosis between graft superior mesenteric artery and recipient aorta accomplished in a shorter time rendered intravenous transfusion not essential for the recipient.

Anastomosis, Surgical↗

Dosimetric evaluation of MRI-based treatment planning for prostate cancer.

The purpose of this study is to evaluate the dosimetric accuracy of MRI-based treatment planning for prostate cancer using a commercial radiotherapy treatment planning system. Three-dimensional conformal plans for 15 prostate patients were generated using the AcQPlan system. For each patient, dose distributions were calculated using patient CT data with and without heterogeneity correction, and using patient MRI data without heterogeneity correction. MR images were post-processed using the gradient distortion correction (GDC) software. The distortion corrected MR images were fused to the corresponding CT for each patient for target and structure delineation. The femoral heads were delineated based on CT. Other anatomic structures relevant to the treatment (i.e., prostate, seminal vesicles, lymph notes, rectum and bladder) were delineated based on MRI. The external contours were drawn separately on CT and MRI. The same internal contours were used in the dose calculation using CT- and MRI-based geometries by directly transferring them between MRI and CT as needed. Treatment plans were evaluated based on maximum dose, isodose distributions and dose-volume histograms. The results confirm previous investigations that there is no clinically significant dose difference between CT-based prostate plans with and without heterogeneity correction. The difference in the target dose between CT- and MRI-based plans using homogeneous geometry was within 2.5%. Our results suggest that MRI-based treatment planning is suitable for radiotherapy of prostate cancer.

Humans↗

Multiple probes reveal a native-like intermediate during low-temperature refolding of ubiquitin.

We investigate the refolding of ubiquitin Phe45Trp/Ile61Ala (Ub(*)I61A) in a low-temperature, high-viscosity buffer, where folding is slowed so that apparent two-state and three-state mechanisms are readily distinguishable. Ub(*)I61A forms a compact ensemble rapidly (as judged from stopped-flow, small-angle X-ray scattering) with a secondary structure signature similar to that of the native state (as judged from stopped-flow circular dichroism from 215 nm to 250 nm), but the fluorescence signature still resembles the guanidinium-denatured state. The compact ensemble forms over a range of solvent and temperature conditions. The native fluorescence signature, which requires the tryptophan residue to be packed tightly, is acquired at least 500 times more slowly. Molecular dynamics simulations at 495 K show no contraction of the backbone in ethylene glycol buffer compared to pure aqueous buffer, and no significant effect on the local backbone structure of the unfolded protein. Only at higher simulation temperature does a backbone contraction appear. Thus, it appears unlikely that the aqueous ethylene glycol buffer fundamentally changes the folding mechanism of ubiquitin. We suggest that ubiquitin forms a compact ensemble with native-like secondary structure, but without tight packing, long before the native state.

Circular Dichroism↗

Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation.

The purpose of this work is to model electron contamination in clinical photon beams and to commission the source model using measured data for Monte Carlo treatment planning. In this work, a planar source is used to represent the contaminant electrons at a plane above the upper jaws. The source size depends on the dimensions of the field size at the isocentre. The energy spectra of the contaminant electrons are predetermined using Monte Carlo simulations for photon beams from different clinical accelerators. A 'random creep' method is employed to derive the weight of the electron contamination source by matching Monte Carlo calculated monoenergetic photon and electron percent depth-dose (PDD) curves with measured PDD curves. We have integrated this electron contamination source into a previously developed multiple source model and validated the model for photon beams from Siemens PRIMUS accelerators. The EGS4 based Monte Carlo user code BEAM and MCSIM were used for linac head sinulation and dose calculation. The Monte Carlo calculated dose distributions were compared with measured data. Our results showed good agreement (less than 2% or 2 mm) for 6, 10 and 18 MV photon beams.

Artifacts↗

Monitor unit calculation for Monte Carlo treatment planning.

In this work, we investigate a formalism for monitor unit (MU) calculation in Monte Carlo based treatment planning. By relating MU to dose measured under reference calibration conditions (central axis, depth of dose maximum in water, 10 cm x 10 cm field defined at 100 cm source-to-surface distance) our formalism determines the MU required for a treatment plan based on the prescription dose and Monte Carlo calculated dose distribution. Detailed descriptions and formulae are given for various clinical situations including conventional treatments and advanced techniques such as intensity-modulated radiotherapy (IMRT) and modulated electron radiotherapy (MERT). Analysis is made of the effects of source modelling, beam modifier simulation and patient dose calculation accuracy, all of which are important factors for absolute dose calculations using Monte Carlo simulations. We have tested the formalism through phantom measurements and the predicted MU values were consistent with measured values to within 2%. The formalism has been used for MU calculation and plan comparison for advanced treatment techniques such as MERT, extracranial stereotactic IMRT, MRI-based treatment planning and intensity-modulated laser-proton therapy studies. It is also used for absolute dose calculations using Monte Carlo simulations for treatment verification, which has become part of our comprehensive IMRT quality assurance programme.

Dose-Response Relationship, Radiation↗

Clinical implementation of intensity-modulated tangential beam irradiation for breast cancer.

A Monte Carlo based intensity-modulated radiation therapy (IMRT) treatment planning system has been developed and used for breast treatment. An iterative method was used for optimization to generate IMRT plans and a step-and-shoot technique was used for beam delivery. The patient setup and incident beam directions were the same as those for conventional tangential photon treatment. The weights for the opposed beamlets in the two tangential beams were determined first by the doses at the depths of the maximum dose at both sides to minimize hot spots. The intensity of an individual beamlet pair was then optimized based on the dose at the midplane. Fine tuning was made to achieve optimal target dose uniformity and to reduce the dose to the heart when necessary. The final dose calculations were performed using the Monte Carlo method and the plans were verified by phantom measurements. The dose distributions and dose-volume-histograms of IMRT plans were compared with those of conventional plans that were generated using a commercial treatment planning system and recalculated using an in-house Monte Carlo system for the first 25 patients. The dose comparisons showed that the percentage volume receiving more than 95% of the prescription dose (V95) and the percentage volume receiving more than 100% of the prescription dose (V100) for the clinical target volume (CTV) of IMRT plans were about the same as those of conventional plans. The percentage volume receiving more than 105% of the prescription dose (V105) for the CTV was reduced from 23.1% to 7.9% on average. The percentage volume of the lung receiving more than 20 Gy dose (V20 Gy) during the entire treatment was reduced by about 10%. The percentage volume of the heart receiving more than 30 Gy dose (V30 Gy) is reduced from 3.3% to 0.3%. Further studies revealed that a less than 5 degrees change in couch angle and collimator angle at patient setup had no significant effect on the dose coverage of CTV but had significant effect on the dose to the lung and heart. The study on the effect of beam spoiler showed that it increased the dose at the buildup region by 0- 13% that varies with location. The machine output linearity and stability for small monitor unit delivery of Siemens accelerators used for this study was checked and found to be suitable for breast IMRT. The total effect of variations was calculated to be less than 1% for typical breast treatments. The beam delivery time was increased by about 2 min compared with conventional tangential treatments. The whole treatment including patient setup and beam delivery can be completed in a 15 min slot. The IMRT technique has been proven practical for breast treatment clinically. The results showed that tangential IMRT improved the dose homogeneity in the breast and reduced the dose to the lung and heart.

Algorithms↗

Intensity modulated radiation therapy using laser-accelerated protons: a Monte Carlo dosimetric study.

In this paper we present Monte Carlo studies of intensity modulated radiation therapy using laser-accelerated proton beams. Laser-accelerated protons coming out of a solid high-density target have broad energy and angular spectra leading to dose distributions that cannot be directly used for therapeutic applications. Through the introduction of a spectrometer-like particle selection system that delivers small pencil beams of protons with desired energy spectra it is feasible to use laser-accelerated protons for intensity modulated radiotherapy. The method presented in this paper is a three-dimensional modulation in which the proton energy spectrum and intensity of each individual beamlet are modulated to yield a homogeneous dose in both the longitudinal and lateral directions. As an evaluation of the efficacy of this method, it has been applied to two prostate cases using a variety of beam arrangements. We have performed a comparison study between intensity modulated photon plans and those for laser-accelerated protons. For identical beam arrangements and the same optimization parameters, proton plans exhibit superior coverage of the target and sparing of neighbouring critical structures. Dose-volume histogram analysis of the resulting dose distributions shows up to 50% reduction of dose to the critical structures. As the number of fields is decreased, the proton modality exhibits a better preservation of the optimization requirements on the target and critical structures. It is shown that for a two-beam arrangement (parallel-opposed) it is possible to achieve both superior target coverage with 5% dose inhomogeneity within the target and excellent sparing of surrounding tissue.

Algorithms↗

A comparative dosimetric study on tangential photon beams, intensity-modulated radiation therapy (IMRT) and modulated electron radiotherapy (MERT) for breast cancer treatment.

Recently, energy- and intensity-modulated electron radiotherapy (MERT) has garnered a growing interest for the treatment of superficial targets. In this work. we carried out a comparative dosimetry study to evaluate MERT, photon beam intensity-modulated radiation therapy (IMRT) and conventional tangential photon beams for the treatment of breast cancer. A Monte Carlo based treatment planning system has been investigated, which consists of a set of software tools to perform accurate dose calculation, treatment optimization, leaf sequencing and plan analysis. We have compared breast treatment plans generated using this home-grown treatment optimization and dose calculation software forthese treatment techniques. The MERT plans were planned with up to two gantry angles and four nominal energies (6, 9, 12 and 16 MeV). The tangential photon treatment plans were planned with 6 MV wedged photon beams. The IMRT plans were planned using both multiple-gantry 6 MV photon beams or two 6 MV tangential beams. Our results show that tangential IMRT can reduce the dose to the lung, heart and contralateral breast compared to conventional tangential wedged beams (up to 50% reduction in high dose volume or 5 Gy in the maximum dose). MERT can reduce the maximum dose to the lung by up to 20 Gy and to the heart by up to 35 Gy compared to conventional tangential wedged beams. Multiple beam angle IMRT can significantly reduce the maximum dose to the lung and heart (up to 20 Gy) but it induces low and medium doses to a large volume of normal tissues including lung, heart and contralateral breast. It is concluded that MERT has superior capabilities to achieve dose conformity both laterally and in the depth direction, which will be well suited for treating superficial targets such as breast cancer.

Breast Neoplasms↗

A quality assurance phantom for IMRT dose verification.

This paper investigates a quality assurance (QA) phantom specially designed to verify the accuracy of dose distributions and monitor units (MU) calculated by clinical treatment planning optimization systems and by the Monte Carlo method for intensity-modulated radiotherapy (IMRT). The QA phantom is a PMMA cylinder of 30 cm diameter and 40 cm length with various bone and lung inserts. A procedure (and formalism) has been developed to measure the absolute dose to water in the PMMA phantom. Another cylindrical phantom of the same dimensions, but made of water, was used to confirm the results obtained with the PMMA phantom. The PMMA phantom was irradiated by 4, 6 and 15 MV photon beams and the dose was measured using an ionization chamber and compared to the results calculated by a commercial inverse planning system (CORVUS, NOMOS, Sewickley, PA) and by the Monte Carlo method. The results show that the dose distributions calculated by both CORVUS and Monte Carlo agreed to within 2% of dose maximum with measured results in the uniform PMMA phantom for both open and intensity-modulated fields. Similar agreement was obtained between Monte Carlo calculations and measured results with the bone and lung heterogeneity inside the PMMA phantom while the CORVUS results were 4% different. The QA phantom has been integrated as a routine QA procedure for the patient's IMRT dose verification at Stanford since 1999.

Equipment Design↗