PubMed Health⌕ Search

Biomedical subjects

J S McGlone

Publications and source records attributed to J S McGlone.

4 recordsLinked to original sources

Three-dimensional representation and analysis of brain energy metabolism.

Quantitative autoradiography of brain glucose metabolism has been combined with digital image processing to represent the brain as a three-dimensional (3-D) reconstruction of brain energy use. Autoradiographs contain enormous amounts of potentially useful data, but conventional analyses, based on tedious manual methods, can sample and analyze only a small portion of this information. Computer 3-D reconstruction provides a mechanism for observing and analyzing all the data; therefore, a system of computer programs was developed for this purpose. The programs use digital imaging methods for image registration, superimpose whole brain data sets, and allow resampling of the 3-D data in arbitrary planes for pixel-by-pixel comparisons among multiple 3-D sets. These programs operate on the mathematical properties of the images alone, obviating the need for manual image alignment. Various statistical analyses can be applied to the data directly to study the patterns of metabolic changes in different experiments. The system is applied to data from experiments on the influence of injectable anesthetics on cerebral glucose metabolism.

Anesthetics↗

Pulse sequence optimization for T2-weighted MR imaging of the brain.

The authors implemented bipolar velocity compensated pulse techniques for T2-weighted MR imaging of the brain. Signal-to-noise (S/N) and image quality was compared for pulse sequences with standard and optimized RF pulses, low and regular bandwidth versions and cardiac triggering. Images from bipolar velocity compensated sequences allowed better visualization of vessels and basilar cisterns and improved image quality relative to standard sequences without velocity compensation. The implementation of optimized RF pulses with bipolar sequences resulted in further improvement in image quality. Single echo sequences consistently had improved image quality and signal-to-noise relative to the second echo of a double echo sequence. Low bandwidth bipolar sequences with extended sampling period had 30% higher S/N, but at the cost of slight loss in edge definition. The highest image quality was obtained with the bipolar, optimized RF, single echo sequence. Using this technique contiguous high quality image slices could be obtained with velocity compensation. The addition of cardiac triggering to bipolar sequences resulted in slight improvement in image quality, but this difference was marginal and probably rarely necessary for MR imaging of the brain.

Brain↗

Single breath-holding scans of the abdomen using FISP and FLASH at 1.5 T.

Single breath-holding gradient echo techniques fast imaging with steady-state free precession (FISP) and fast low angle shot (FLASH) images were evaluated in the study of the abdomen in 16 patients (13 liver, two kidney, and one pancreas examinations). Gradient echo images were compared retrospectively with conventional spin echo images for image quality (depiction of pathology and representation of anatomic detail), and contrast characteristics were evaluated. All lesions were shown on gradient echo images, and in three of 16 cases gradient echo images were more diagnostic than spin echo images. On both FISP and FLASH images, most hepatic metastases were hyperintense relative to normal liver. The predicted flip angles for maximal contrast for the liver were modeled from signal intensity equations for FISP and FLASH and yielded predicted flip angles of approximately 40-55 degrees for FISP and 15-25 degrees for FLASH. Peak signal-to-noise ratio in liver of normal volunteers occurred at approximately 30 degrees for both FISP and FLASH. Single breath-holding gradient echo images are useful in the evaluation of abdominal structures and this study provides a framework for future work.

Abdominal Neoplasms↗