PubMed Health⌕ Search

Biomedical subjects

J S Nelson

Publications and source records attributed to J S Nelson.

At least 19 recordsLinked to original sources

Improving fertility in beef cow recipients.

In the 1970s, bovine embryo transfer (ET) shifted from research in a laboratory environment to commercialization of this technology for beef producers. With the quarantine requirements and expense of importing Continental breeds of cattle from Europe, embryo transfer became the logical means to reproduce greater numbers of these animals at a lower cost. The ET industry grew very rapidly and soon would become what it is today, a common practice utilized by select ranchers and breeders. Research over the years has primarily focused on methods to increase the number of ovulations and fertilized ova from the donor female, but the total number of transferable embryos has not changed markedly in the last 20 years. More recent advances have been in the area of in vitro production of embryos that allow for greater numbers of embryos to be produced and easier accessibility to incorporate technologies such as sexed sperm, sperm injection, or transgenics. This paper will focus on the second part of the equation, the recipient, and decisions that will enable both the customers and practitioners to most efficiently utilize embryos from superovulation, in vitro production, or nuclear transfer, so that the maximum number of pregnancies can be produced.

Animals↗

Excessive daytime sleepiness and subsequent development of Parkinson disease.

OBJECTIVE: To determine if excessive daytime sleepiness (EDS) can predate future Parkinson disease (PD). METHODS: EDS was assessed in 3,078 men aged 71 to 93 years in the Honolulu-Asia Aging Study from 1991 to 1993. All were free of prevalent PD and dementia. Follow-up for incident PD was based on three repeat neurologic assessments from 1994 to 2001. RESULTS: During the course of follow-up, 43 men developed PD (19.9/10,000 person-years). After age adjustment, there was more than a threefold excess in the risk of PD in men with EDS vs men without EDS (55.3 vs 17.0/10,000 person-years; odds ratio [OR] = 3.3; 95% CI = 1.4 to 7.0; p = 0.004). Additional adjustment for insomnia, cognitive function, depressed mood, midlife cigarette smoking and coffee drinking, and other factors failed to alter the association between EDS and PD (OR = 2.8; 95% CI = 1.1 to 6.4; p = 0.014). Other sleep related features such as insomnia, daytime napping, early morning grogginess, and frequent nocturnal awakening showed little relation with the risk of PD. CONCLUSIONS: Excessive daytime sleepiness may be associated with an increased risk of developing Parkinson disease.

Aged↗

Consumption of milk and calcium in midlife and the future risk of Parkinson disease.

OBJECTIVE: To examine the relation between milk and calcium intake in midlife and the risk of Parkinson disease (PD). METHODS: Findings are based on dietary intake observed from 1965 to 1968 in 7,504 men ages 45 to 68 in the Honolulu Heart Program. Men were followed for 30 years for incident PD. RESULTS: In the course of follow-up, 128 developed PD (7.1/10,000 person-years). Age-adjusted incidence of PD increased with milk intake from 6.9/10,000 person-years in men who consumed no milk to 14.9/10,000 person-years in men who consumed >16 oz/day (p = 0.017). After further adjustment for dietary and other factors, there was a 2.3-fold excess of PD (95% CI 1.3 to 4.1) in the highest intake group (>16 oz/day) vs those who consumed no milk. The effect of milk consumption on PD was also independent of the intake of calcium. Calcium from dairy and nondairy sources had no apparent relation with the risk of PD. CONCLUSIONS: Findings suggest that milk intake is associated with an increased risk of Parkinson disease. Whether observed effects are mediated through nutrients other than calcium or through neurotoxic contaminants warrants further study.

Age of Onset↗

Methemoglobin formation during laser induced photothermolysis of vascular skin lesions.

BACKGROUND AND OBJECTIVE: Monitoring dynamic changes during laser induced photothermolysis of vascular skin lesions is essential for obtaining an optimal therapeutic result. Rapid photoinduced thermal damage occurs at a threshold temperature of about 70 degrees C. It is therefore, relevant to identify markers to indicate if this threshold temperature has been reached. Methemoglobin, which is formed by a photo-induced oxidation of hemoglobin, indicates that the temperature has reached this threshold value. This study presents a proof of concept of a method for monitoring the in vivo presence of methemoglobin immediately after laser exposure. STUDY DESIGN/MATERIALS AND METHODS: The present study was designed to investigate the in vivo temperature dependence of hemoglobin absorption in the 450-800 nm spectrum range. In vivo diffuse reflectance measurements of port-wine stain (PWS) and telangiectasia were performed prior to, and immediately after, laser treatment with a pulsed dye laser (PDL) at 585 nm wavelength. RESULTS: In vivo measurements following laser treatment of vascular skin lesions showed an immediate increase in the optical absorption of blood. This effect, caused by thermal stress, is a result of an increased dermal blood volume fraction and methemoglobin formation. The effect is light dose dependent, and reflectance spectra revealed methemoglobin formation in patients treated with fluences above 5 J/cm2 at 585 nm wavelength. CONCLUSIONS: It was proved that methemoglobin can be measured in vivo by reflectance spectroscopy. Measurements of the average methemoglobin concentrations immediately after laser exposure may be a valuable diagnostic tool to verify that the blood temperature has been sufficiently high to induce thermal damage to the vessel wall.

Adolescent↗

Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber.

We have developed an ultrahigh-resolution optical coherence tomographic system in which broadband continuum generation from a photonic crystal fiber is used to produce high longitudinal resolution. Longitudinal resolution of 1.3-microm has been achieved in a biological tissue by use of continuum light from 800 to 1400 nm. The system employed a dynamic-focusing tracking method to maintain high lateral resolution over a large imaging depth. Subcellular imaging is demonstrated.

Animals↗

Cooling efficiency of cryogen spray during laser therapy of skin.

BACKGROUND AND OBJECTIVES: Cryogen spray cooling (CSC) is used extensively for epidermal protection during laser-induced photothermolysis of port wine stains and other vascular skin lesions. The efficacy of CSC depends critically on the heat transfer coefficient (H) at the skin surface for which, however, no reliable values exist. Reported values for H, based on tissue phantoms, vary from 1,600 to 60,000 W/m(2) K. STUDY DESIGN/MATERIALS AND METHODS: A simple experimental model was designed and constructed, consisting of a pure silver-measuring disk (diameter 10 mm, thickness approximately 1 mm), embedded in a thermal insulator. The disk was covered with a 10 microm thick stratum corneum layer, detached from in vivo human skin. The heat transfer coefficient of the stratum corneum/cryogen interface was measured during CSC with short spurts of atomized tetrafluoroethane. RESULTS: H was found to be dependent on the specific design of the cryogen valve and nozzle. With nozzles used in typical clinical settings, H was 11,500 W/m(2) K, when averaged over a 100 ms spurt, and 8,000 W/m(2) K when averaged over a 200 ms spurt. CONCLUSIONS: The presented model enables accurate prediction of H and thus improve control over temperature depth profile and cooling efficiency during laser therapy. Thereby, it may contribute to improvement of therapeutic outcome.

Cryotherapy↗

Midlife adiposity and the future risk of Parkinson's disease.

BACKGROUND: Evidence suggests that nigrostriatal system disorders are associated with PD and adiposity. Whether patterns of adiposity coexist or predate clinical PD is unknown. This report examines the relation between midlife adiposity and the risk of PD. METHODS: Measurement of adiposity occurred from 1965 to 1968 in 7,990 men in the Honolulu Heart Program (aged 45 to 68 years and without PD). Adiposity measures included body mass index (BMI), subscapular skinfold thickness (SSF), and triceps skinfold thickness (TSF). Follow-up for incident PD occurred over a 30-year period. RESULTS: During the course of follow-up, PD was observed in 137 men. Among the measures of adiposity, age-adjusted incidence of PD increased threefold from 3.7/10,000 person-years in the bottom quartile of TSF (1 to 5 mm) to 11.1/10,000 person-years in the top quartile (11 to 32 mm, p < 0.001). Effects of TSF on PD were independent of cigarette smoking, coffee consumption, physical activity, daily caloric and fat intake, and the other measures of adiposity (p < 0.001). Whereas rates of PD were lowest in the bottom quartile of BMI and SSF vs higher quartiles, associations with PD were weaker than they were for TSF. The effect of TSF on clinical onset before age 65 years was similar to the effect that was observed in later life. CONCLUSIONS: Increased triceps skinfold thickness measured in midlife is associated with an elevated risk of future PD. Whether patterns of adiposity reflect a unique metabolic pathology in individuals at a high risk of PD warrants further study.

Adipose Tissue↗

Use of laser photocoagulation for treatment of cutaneous angiomatosis in one dog and two cats.

One dog and 2 cats were evaluated because of multiple progressively enlarging cutaneous vascular plaques. Biopsies were performed and revealed small well-circumscribed dermal nodules of dilated fully enclosed blood-filled spaces lined by single layers of endothelial cells aligned on thin fibrous walls, with minimal mitotic activity. A diagnosis of cutaneous angiomatosis was made in all 3 animals. Cutaneous angiomatosis is a progressive proliferative lesion of vascular tissue involving the dermis and subcutaneous tissues of dogs and cats. Lasers of selected wavelengths have been used to induce photothermal coagulation of hemoglobin-containing cutaneous lesions in humans; argon-pumped dye and neodymium:yttrium-aluminum-garnet lasers were used to treat the cutaneous lesions in the animals of this report. Laser treatment may provide an alternative to wide surgical resection or limb amputation for management of this condition in veterinary patients.

Angiomatosis↗

Laser-mediated cartilage reshaping with feedback-controlled cryogen spray cooling: biophysical properties and viability.

BACKGROUND AND OBJECTIVE: Recent studies have indicated that chondrocyte viability decreases with prolonged or repeated laser irradiation. To optimize laser-mediated cartilage reshaping, the heating process must be finely controlled. In this study, we use high-power Nd:YAG laser irradiation (lambda = 1.32 microm) combined with cryogen spray cooling (CSC) in an attempt to reshape porcine septal cartilage while enhancing chondrocyte viability. STUDY DESIGN/MATERIALS AND METHODS: Chondrocyte viability was determined after high-power (50 W/cm2) Nd:YAG-mediated cartilage reshaping with and without cryogen spray cooling (CSC) and correlated with dynamic measurements of tissue optical and thermal properties. RESULTS: After 1.5 to 2.0 seconds of laser exposure, characteristic changes in diffuse reflectance (indicating the onset of accelerated stress relaxation) was observed in both laser only and laser with CSC specimens. After 2 seconds of laser exposure, specimens in both groups retained the curved shape for up to 14 days. After one laser exposure, chondrocyte viability was 94.35 +/- 6.1% with CSC and 68.77 +/- 20.1% (P < 0.05) without CSC. After two laser exposures, a similar trend was observed with CSC (70.18 +/- 16.44%) opposed to without CSC (28 +/- 45%; P < 0.05). CONCLUSION: CSC during high-power laser irradiation allows rapid heating while minimizing extreme front surface temperature elevations and axial thermal gradients. Laser irradiation with CSC can be used to effectively reshape cartilage tissue with the additional advantage of increasing chondrocyte viability.

Aerosol Propellants↗

Influence of nozzle-to-skin distance in cryogen spray cooling for dermatologic laser surgery.

BACKGROUND AND OBJECTIVE: Cryogen sprays are used for cooling human skin during various laser treatments. Since characteristics of such sprays have not been completely understood, the optimal atomizing nozzle design and operating conditions for cooling human skin remain to be determined. MATERIALS AND METHODS: Two commercial cryogenic spray nozzles are characterized by imaging the sprays and the resulting areas on a substrate, as well as by measurements of the average spray droplet diameters, velocities, temperatures, and heat transfer coefficients at the cryogen-substrate interface; all as a function of distance from the nozzle tip. RESULTS: Size of spray cones and sprayed areas vary with distance and nozzle. Average droplet diameter and velocity increase with distance in the vicinity of the nozzle, slowly decreasing after a certain maximum is reached. Spray temperature decreases with distance due to the extraction of latent heat of vaporization. At larger distances, temperature increases due to complete evaporation of spray droplets. These three variables combined determine the heat transfer coefficient, which may also initially increase with distance, but eventually decreases as nozzles are moved far from the target. CONCLUSIONS: Sprayed areas and heat extraction efficiencies produced by current commercial nozzles may be significantly modified by varying the distance between the nozzle and the sprayed surface.

Cryotherapy↗

Er:YAG laser skin resurfacing using repetitive long-pulse exposure and cryogen spray cooling: I. Histological study.

BACKGROUND AND OBJECTIVE: To evaluate histologically the characteristics of repetitive Er:YAG laser exposure of skin in combination with cryogen spray cooling (CSC), and its potential as a method of laser skin resurfacing. STUDY DESIGN/MATERIALS AND METHODS: Rat skin was irradiated in vivo with sequences of 10 Er:YAG laser pulses (repetition rate 20 Hz, pulse duration 150 or 550 micros, single-pulse fluence 1.3-5.2 J/cm(2)). In some examples, CSC was applied to reduce epidermal injury. Histologic evaluation was performed 1 hour, 1 day, 5 days, and 4 weeks post-irradiation. RESULTS: A sequence of ten 550-micros pulses with fluences around 2 J/cm(2) resulted in acute dermal collagen coagulation to a depth of approximately 250 microm, without complete epidermal ablation. CSC improved epidermal preservation, but also diminished the coagulation depth. Four weeks after irradiation, neo-collagen formation was observed to depths in excess of 100 microm. CONCLUSIONS: Dermal collagen coagulation and neo-collagen formation to depths similar to those observed after CO(2) laser resurfacing can be achieved without complete ablation of the epidermis by rapidly stacking long Er:YAG laser pulses. Application of CSC does not offer significant epidermal protection for a given dermal coagulation depth.

Animals↗

Er:YAG laser skin resurfacing using repetitive long-pulse exposure and cryogen spray cooling: II. Theoretical analysis.

BACKGROUND AND OBJECTIVE: To analyze the effects of laser pulse duration and cryogen spray cooling (CSC) on epidermal damage and depth of collagen coagulation in skin resurfacing with repetitive Er:YAG laser irradiation. STUDY DESIGN/MATERIALS AND METHODS: Evolution of temperature field in skin is calculated using a simple one-dimensional model of sub-ablative pulsed laser exposure and CSC. The model is solved numerically for laser pulse durations of 150 and 600 microsec, and 6 msec cryogen spurts delivered just prior to ("pre-cooling"), or during and after ("post-cooling") the 600 microsec laser pulse. RESULTS: The model indicates a minimal influence of pulse duration on the extent of thermal effect in dermis, but less epidermal damage with 600 microsec pulses as compared to 150 microsec at the same pulse fluence. Application of pre- or post-cooling reduces the peak surface temperature after laser exposure and accelerates its relaxation toward the base temperature to a different degree. However, the temperature profile in skin after 50 msec is in either example very similar to that after a lower-energy laser pulse without CSC. CONCLUSIONS: When applied in combination with repetitive Er:YAG laser exposure, CSC strongly affects the amount of heat available for dermal coagulation. As a result, CSC may not provide spatially selective epidermal protection in Er:YAG laser skin resurfacing.

Burns↗

Theramal, mechanical, optical, and morphologic changes in bovine nucleus pulposus induced by Nd:YAG (lambda = 1.32 microm) laser irradiation.

UNLABELLED: BACKGROUND AND OBJECTIVE To examine the biophysical effects of photothermal heating on herniated intervertebral discs during laser decompression surgery. STUDY DESIGN/MATERIALS AND METHODS: Ex vivo bovine nucleus pulposus specimens were irradiated with a Nd: YAG laser (lambda = 1.32 microm, 100 seconds exposure time, 9-31 W/cm(2), 4.8 mm spot diameter), whereas changes in tissue thermal, mechanical, and optical properties were monitored by using, respectively, infrared radiometry, tissue tension measurements, and diffuse reflectance from a HeNe probe laser. Morphologic changes and mass reduction were monitored by recording shape changes on video and weighing specimens before and after laser exposure. RESULTS: At power densities below 20 W/cm(2), evaporation of water and specimen volume reduction (shrinking) were consistently observed on video during irradiation. In contrast, above 20 W/cm(2), vapor bubbles formed within the specimen matrix and subsequently ruptured (releasing heated vapors). When radiometric surface temperature approaches approximately 60 to 70 degrees C (denaturation threshold for tissue), tissue tension begins to increase, which is consistent with observations of specimen length reduction. The onset of this change in tissue tension is also reflected in characteristic alterations in diffuse reflectance. With cessation of laser irradiation, a sustained increase in tissue tension is observed, which is consistent with changes in specimen length and volume. Higher laser power results in a faster heating rate and subsequently an accelerated tension change. Specimen mass reduction increased with irradiance from 19 to 72% of the initial mass for 9--31 W/cm(2), respectively. Irradiated specimens did not return to their original shape after immersion in saline (48 hours) in contrast to air-dried specimens (24 hours), which returned to their original shape and size. CONCLUSION: These observations suggest that photothermal heating results in irreversible matrix alteration causing shape change and volume reduction (observed on video and evidenced by the increase in tissue tension) taking place at approximately 65 degrees C. Inasmuch as high laser power results in vapor bubble formation and specimen tearing, the heating process must be controlled. Diffuse reflectance measurements provide a noncontact, highly sensitive means to monitor dynamically changes in tension of nucleus purposus.

Animals↗

Cryogen spray cooling in laser dermatology: effects of ambient humidity and frost formation.

BACKGROUND AND OBJECTIVE: Dynamics of cryogen spray deposition, water condensation and frost formation is studied in relationship to cooling rate and efficiency of cryogen spray cooling (CSC) in combination with laser dermatologic surgery. STUDY DESIGN/MATERIALS AND METHODS: A high-speed video camera was used to image the surface of human skin during and after CSC using a commercial device. The influence of ambient humidity on heat extraction dynamics was measured in an atmosphere-controlled chamber using an epoxy block with embedded thermocouples. RESULTS: A layer of liquid cryogen may remain on the skin after the spurt termination and prolong the cooling time well beyond that selected by the user. A layer of frost starts forming only after the liquid cryogen retracts. Condensation of ambient water vapor and subsequent frost formation deposit latent heat to the target site and may significantly impair the CSC cooling rate. CONCLUSIONS: Frost formation following CSC does not usually affect laser dosage delivered for therapy of subsurface targets. Moreover, frost formation may reduce the risk of cryo-injury associated with prolonged cooling. The epidermal protection during CSC assisted laser dermatologic surgery can be further improved by eliminating the adverse influence of ambient humidity.

Aerosol Propellants↗

Phosphoramidate oligonucleotides as potent antisense molecules in cells and in vivo.

Antisense oligonucleotides are designed to specifically hybridize to a target messenger RNA (mRNA) and interfere with the synthesis of the encoded protein. Uniformly modified oligonucleotides containing N3'-P5' phosphoramidate linkages exhibit (NP) extremely high-affinity binding to single-stranded RNA, do not induce RNase H activity, and are resistant to cellular nucleases. In the present work, we demonstrate that phosphoramidate oligonucleotides are effective at inhibiting gene expression at the mRNA level, by binding to their complementary target present in the 5'-untranslated region. Their mechanism of action was demonstrated by comparative analysis of three expression systems that differ only by the composition of the oligonucleotide target sequence (HIV-1 polypurine tract or PPT sequence) present just upstream from the AUG codon of the firefly luciferase reporter gene: the experiments have been done on isolated cells using oligonucleotide delivery mediated by cationic molecules or streptolysin O (SLO), and in vivo by oligonucleotide electrotransfer to skeletal muscle. In our experimental system phosphoramidate oligonucleotides act as potent and specific antisense agents by steric blocking of translation initiation; they may prove useful to modulate RNA metabolism while maintaining RNA integrity.

5' Untranslated Regions↗

Cryogen spray cooling and pulsed dye laser treatment of cutaneous hemangiomas.

When a cryogen spurt is applied to the skin surface for tens of milliseconds, cooling remains localized in the epidermis, leaving the temperature of deeper hemangioma vessels unchanged. The objective of this study was to compare the efficacy and safety of noncooled laser treatment (NC-LT) vs. cryogen spray cooling plus laser treatment (CSC-LT) for cutaneous hemangiomas in a large series of patients. A retrospective review was conducted of 164 patients treated with the pulsed dye laser (lambda = 585 nm; taurho = 450 microsec) over an 8-year period. Eighty-two patients received NC-LT using light doses of 5.5 to 8 J per square centimeter. Subsequently, 82 patients received CSC-LT using light doses of 9 to 10 J per square centimeter. The primary efficacy measure was quantitative assessment of improvements in lesional volume, texture, and color. Safety was evaluated for each treatment group by monitoring for adverse effects. Based on chi-squared analysis, there were clinical and significant differences in the number of treatments (p = 0.001), and improvement in volume (p = 0.008) and texture (p = 0.001) of the CSC-LT group compared with the NC-LT group. Permanent adverse effects were not observed in either group. In conclusion, CSC permitted the use of higher incident light doses for treatment of cutaneous hemangiomas, resulting in fewer treatments required and better improvement in lesional volume and texture.

Adolescent↗

In vivo burn depth determination by high-speed fiber-based polarization sensitive optical coherence tomography.

We report the first application of high-speed fiber-based polarization sensitive optical coherence tomography (PS-OCT) to image burned tissue in vivo. Thermal injury denatures collagen in skin and PS-OCT can measure the reduction in collagen birefringence using depth resolved changes in the polarization state of light propagated in, and reflected from, the tissue. Stokes vectors were calculated for each point in a scan and birefringence relative to incident polarization determined using four incident polarization states. Using a high-speed fiber-based PS-OCT system on rat skin burned for varying periods of time, a correlation between birefringence and actual burn depth determined by histological analysis was established. In conclusion, PS-OCT has potential use for noninvasive assessment of burn depth.

Animals↗

Imaging blood flow in human port-wine stain in situ and in real time using optical Doppler tomography.

BACKGROUND: Optical Doppler tomography (ODT) combines laser Doppler flowmetry with optical coherence tomography to obtain high-resolution images of blood flow in human skin in situ and in real time. OBSERVATIONS: We present a case in which ODT was used on a patient with a port-wine stain (PWS) birthmark to document the change of blood flow in response to laser therapy. It might be possible to use ODT blood flow measurements in situ to assist in assessing the efficacy of laser PWS therapy. If partial restoration of flow occurs immediately or shortly after laser exposure, indicative of reperfusion due to inadequate blood vessel injury, the PWS can be retreated using higher light dosages. Retreatment is continued until the measured Doppler shift is zero due to a permanent reduction in blood flow, indicative of irreversible microthrombus formation in the PWS vessels. CONCLUSIONS: We have demonstrated that ODT may be used for noninvasive imaging of blood vessels in PWS skin. Moreover, ODT will potentially allow laser therapy to be optimized on an individual patient basis by providing a fast, semiquantitative evaluation of the efficacy of PWS laser therapy in situ and in real time.

Humans↗