PubMed Health⌕ Search

Biomedical subjects

J Sagartz

Publications and source records attributed to J Sagartz.

4 recordsLinked to original sources

Neonatal mouse model: review of methods and results.

The neonatal mouse model, in various forms, has been used experimentally since 1959 and a large number of chemicals have been tested. The neonatal model is known to be very sensitive for the detection of carcinogens that operate via a genotoxic mode of action. In contrast, it is known not to respond to chemicals that act via epigenetic mechanisms, commonly observed in the two-year carcinogenicity studies. As such, the model has a high sensitivity and specificity in its response. Dose selection for the neonatal model is based on the maximum tolerated or feasible dose. Traditionally, compounds have been tested via the IP route of administration in this model. In some cases, this has limited the amount of material that can be administered because of the low dosing volumes (10 to 20 microL) that can be administered IP. For the ILSI project, the neonatal model was adapted for oral administration, which has the advantages of being the same route for which most pharmaceuticals are administered. In addition, a 10-fold increase in the volume of administration (100 to 200 microL) and the ability to dose drugs in suspension, permits much higher doses to be used as compared to the IP route of administration. The spontaneous tumors in the neonatal model occurred mainly in the liver of male mice and lung of male and female mice with a few tumors observed in the Harderian gland. The positive control, DEN produced a robust, uniform, and reproducible tumor response with the target organs essentially limited to liver and lung. A total of 13 compounds out of the 21 ILSI ACT compounds were evaluated in the neonatal model involving 18 studies with duplicate studies for some compounds. The genotoxic carcinogens including those used as positive controls were clearly positive (cyclophosphamide, diethylnitrosamine, 6-nitrochrysene). The non-genotoxic rodent carcinogens were clearly negative (chlorpromazine, sulfisoxazole, sulfamethoxazole, clofibrate, DEHP, haloperidol, metaproteranol, and phenobarbital). The non-genotoxic human carcinogen (cyclosporin) was clearly negative. The two other human carcinogens phenacetin and DES were negative and interestingly estradiol was negative in one of the two oral studies, but was clearly positive in the other. Considering the mode of action for three of the human carcinogens (DES, cyclosporin and phenacetin), which were negative in this model, the mode of action in humans is likely to be epigenetic. Overall, for the 3 clearly genotoxic chemicals, all were positive. For the 9 clearly non-genotoxic chemicals, all 9 were negative. The two human carcinogens for which genotoxicity may or may not play a role (DES and phenacetin) were negative and estradiol was positive in I of the two oral studies. Overall, the extensive database for compounds tested in the neonatal mouse model would support its use as an alternative model for the assessment of the carcinogenic potential of a chemical. The model responds to chemicals that act via a genotoxic mode of action that represent a greater concern for human cancer risk.

Administration, Oral↗

Effects of low humidity on the rat middle ear.

Secretory otitis media is common in the winter, and the possible risk factors are numerous. This study examines the effect of low humidity on the middle ear using a Sprague-Dawley rat model: 23 test rats housed for 5 days in a low-humidity environment (10% to 12% relative humidity) and 23 control rats housed at 50% to 55% relative humidity. Microscopic ear examinations were graded for otitis media with effusion (OME) before testing and on test days 3 and 5. The mucosa of the middle ears and eustachian tubes was examined histopathologically. Significantly more effusions were observed in the low-humidity group on test days 3 (P = .003) and 5 (P = .01), but no intergroup histopathologic differences were noted. We conclude that a low-humidity environment contributed to the development of OME in the test animals, and that low-humidity warrants further investigation as a contributing factor in childhood middle ear disease.

Animals↗

Evaluation of two epoxy ether compounds for biocompatible potential.

Bovine arterial tissue exposed to two epoxy ether compounds (Denacol EX-313 and Denacol EX-810) was evaluated for its biocompatible potential by in vitro and in vivo test procedures. The battery of test procedures included percent Inhibition of Cell Growth, Medium Eluate Method (MEM), Agar Overlay (AO), Blood Compatibility, Acute Mouse Systemic Injection, Rabbit Intracutaneous Irritation, Rabbit Subcutaneous Implantation, Guinea Pig Maximization, and Ames Tests. The epoxy exposed tissue was found to be noncytotoxic, nonmutagenic, and biocompatible by the test methods employed. In addition, the maximum concentrations of the unreacted Denacol EX-313 and EX-810 solutions found to demonstrate noncytotoxic reactions by the MEM and AO procedures were identified as 55 and 60 ppm for the MEM and 150 and 200 ppm for the AO procedure, respectively. These studies suggest that Denacol EX-313 and EX-810 are acceptable solutions for the processing of implantable tissue provided the epoxy residuals remain below those levels found to be cytotoxic.

Animals↗