PubMed Health⌕ Search

Biomedical subjects

J Samskog

Publications and source records attributed to J Samskog.

3 recordsLinked to original sources

Optimization of capillary electrophoresis conditions for coupling to a mass spectrometer via a sheathless interface.

When optimizing a capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) system, consideration has to be given not only to the separation but also to the electrospray stability. Methods developed for CE/UV analysis of drugs and peptides were considered and modified to be suitable for a CE/MS system with a robust sheathless interface. Different concentrations of the organic modifiers acetonitrile, methanol and 2-propanol were used in the separation buffer. The type and concentrations of these modifiers were also compared with reference to electrospray stability, sensitivity and time of analysis. In addition, different ionic strengths in the buffers were evaluated with reference to electrospray stability. The repeatability was used for the estimation of electrospray stability. The degree to which these parameters influenced the separation and the ESI stability was studied using a nine-peptide standard mixture and the antibiotic drugs bacampicillin and ampicillin as test substances. The analysis time and resolution were used as measures of the efficiency of the separation. A time-of-flight MS analyzer was used since it has the potential advantages of becoming a better fit for integration of CE with MS owing to the speed and sensitivity of this mass analyzer. The detection limit, i.e. 1 microM, for bacampicillin was comparable to what could be achieved with CE/MS on a quadrupole instrument using selected ion monitoring and sheath flow ESI.

Electrophoresis, Capillary↗

Current awareness.

In order to keep subscribers up-to-date with the latest developments in their field, John Wiley & Sons are providing a current awareness service in each issue of the journal. The bibliography contains newly published material in the field of mass spectrometry. Each bibliography is divided into 11 sections: 1 Books, Reviews & Symposia; 2 Instrumental Techniques & Methods; 3 Gas Phase Ion Chemistry; 4 Biology/Biochemistry: Amino Acids, Peptides & Proteins; Carbohydrates; Lipids; Nucleic Acids; 5 Pharmacology/Toxicology; 6 Natural Products; 7 Analysis of Organic Compounds; 8 Analysis of Inorganics/Organometallics; 9 Surface Analysis; 10 Environmental Analysis; 11 Elemental Analysis. Within each section, articles are listed in alphabetical order with respect to author (5 Weeks journals - Search completed at 27th. Apr 2000)

Bibliographies as Topic↗

Reversed-phase ion-pair chromatography coupled to electrospray ionisation mass spectrometry by on-line removal of the counter-ions.

A strong anion-exchanger was used as a trapping column to perform on-line coupling of ion-pair chromatography with electrospray ionisation mass spectrometry. Ion-pairing reagents were used to retain polar analytes of low molecular mass away from the solvent front in reversed-phase LC. The trapping column enabled removal of the non-volatile counter-ions from the mobile phase prior to detection, so that the electrospray process could be performed with favourable ionisation conditions and without contamination of the interface. The efficiency of the trapping process was studied for 1-octanesulfonic acid and sodium dodecyl sulfate as ion-pairing reagents. Using this on-line trapping method, biopterin and guanidine could be retained with a k'>2 and detected by electrospray mass spectrometry with a stable signal.

Anion Exchange Resins↗