Drugs acting as plasticizers in polymeric systems: a quantitative treatment.

The objective of the present study was to investigate and quantify the effects of ibuprofen, chlorpheniramine maleate and metoprolol tartrate on the thermal, mechanical and diffusional properties of polyacrylate-based films. Thin drug-containing films were prepared from organic Eudragit RS solutions and physicochemically characterized with respect to their glass transition temperature, mechanical properties and drug release kinetics in phosphate buffer pH 7.4. The apparent diffusion coefficient of the drug within the polymeric systems was determined by fitting an adequate solution of Fick's second law of diffusion to the experimentally determined release profiles. Importantly, the glass transition temperature of the films significantly decreased with increasing initial drug content, whereas the film flexibility and drug release rate increased. This clearly indicates that the three drugs act as efficient plasticizers for Eudragit RS. Interestingly, the mathematical analysis revealed that drug release was primarily controlled by diffusion. An increase in the initial drug content resulted in increased drug diffusivities and, thus, accelerated (absolute and relative) drug release rates. Importantly, quantitative relationships could be established between the drug diffusivity and the initial drug content. Based on this knowledge, the effects of the films' composition and thickness on the resulting drug release kinetics (also from coated solid dosage forms) can be predicted in a quantitative way.

Chemistry, Pharmaceutical↗

Local controlled drug delivery to the brain: mathematical modeling of the underlying mass transport mechanisms.

The mass transport mechanisms involved in the controlled delivery of drugs to living brain tissue are complex and yet not fully understood. Often the drug is embedded within a polymeric or lipidic matrix, which is directly administered into the brain tissue, that is, intracranially. Different types of systems, including microparticles and disc- or rod-shaped implants are used to control the release rate and, thus, to optimize the drug concentrations at the site of action in the brain over prolonged periods of time. Most of these dosage forms are biodegradable to avoid the need for the removal of empty remnants after drug exhaustion. Various physical and chemical processes are involved in the control of drug release from these systems, including water penetration, drug dissolution, degradation of the matrix and drug diffusion. Once the drug has been released from the delivery system, it has to be transported through the living brain tissue to the target site(s). Again, a variety of phenomena, including diffusion, drug metabolism and degradation, passive or active uptake into CNS tissue and convection can be of importance for the fate of the drug. An overview is given of the current knowledge of the nature of barriers to free access of drug to tumour sites within the brain and the state of the art of: (i) mathematical modeling approaches describing the physical transport processes and chemical reactions which can occur in different types of intracranially administered drug delivery systems, and of (ii) theories quantifying the mass transport phenomena occurring after drug release in the living tissue. Both, simplified as well as complex mathematical models are presented and their major advantages and shortcomings discussed. Interestingly, there is a significant lack of mechanistically realistic, comprehensive theories describing both parts in detail, namely, drug transport in the dosage form and in the living brain tissue. High quality experimental data on drug concentrations in the brain tissue are difficult to obtain, hence this is itself an issue in testing mathematical approaches. As a future perspective, the potential benefits and limitations of these mathematical theories aiming to facilitate the design of advanced intracranial drug delivery systems and to improve the efficiency of the respective pharmacotherapies are discussed.

Animals↗

Controlled drug release from Gelucire-based matrix pellets: experiment and theory.

The aim of this work was to elucidate the underlying drug release mechanisms from lipidic matrix pellets, using theophylline and Gelucire 50/02 as model drug and carrier material, respectively. Pellets were prepared by two different techniques: melt-solidification and extrusion-spheronization. The effects of different formulations and processing parameters on the resulting drug release kinetics in 0.1N HCl and phosphate buffer pH 7.4 were studied and the obtained results analyzed using adequate mathematical models in order to get further insight into the underlying mass transport mechanisms. The type of preparation technique was found to strongly affect the underlying drug release mechanisms. Drug release from pellets prepared by the melt-solidification method was primarily controlled by pure diffusion, whereas drug release from pellets prepared by the extrusion-spheronization method was purely diffusion-controlled only at early time points. After approximately 2h, the pellets started to disintegrate, resulting in decreased diffusion pathway lengths and, thus, increased drug release rates. Furthermore, the curing conditions significantly affected the theophylline release kinetics, whereas varying the initial drug loading from 20 to 50% (w/w) resulted only in a slight increase in the relative drug release rate. Interestingly, the effects of the size of pellets prepared by the melt-solidification method on the resulting drug release kinetics could be quantitatively predicted using an analytical solution of Fick's second law of diffusion. These predictions could be verified by independent experiments.

Delayed-Action Preparations↗

Programmable implants--from pulsatile to controlled release.

The aim of this study was to develop programmable implants with a reproducible delayed onset of release followed by several weeks of controlled release. For this purpose, a drug-loaded core was embedded into a drug-free bulk-eroding poly(D,L lactic-co-glycolic acid) or poly(D,L lactic acid) mantle. The manufacturing procedure was established and optimized for three mantle materials, which showed delay times ranging from 7 to 83 days. Triglycerides with fatty acid chain lengths from C12 to C18 were investigated as core materials, producing release periods from 2 to 16 weeks. Concomitantly, applying a convolution/deconvolution model showed the possibility of theoretical prediction of the resulting release profiles.

Arylsulfonates↗

Effects of the type of release medium on drug release from PLGA-based microparticles: experiment and theory.

The major objectives of the present study were: (i) to prepare 5-fluorouracil (5-FU)-loaded, poly(lactic-co-glycolic acid) (PLGA)-based microparticles, which can be used for the treatment of brain tumors, (ii) to study the effects of the type of release medium on the resulting drug release kinetics, and (iii) to get further insight into the underlying drug release mechanisms. Spherical microparticles were prepared by a solvent extraction method and characterized using different techniques, including size exclusion chromatography (SEC), differential scanning calorimetry (DSC), scanning electron microscopy (SEM) and particle size analysis before and upon exposure to various release media. Interestingly, very different drug release patterns (including mono-, bi- and tri-phasic ones) were observed, depending on the pH, osmolarity and temperature of the release medium. An adequate mathematical theory was used to quantitatively describe the experimentally measured 5-FU release patterns. The model considers the limited solubility of the drug, polymer degradation as well as drug diffusion and allowed to determine system and release medium specific parameters, such as the diffusion coefficient of the drug. In particular, the pH and temperature of the release medium were found to be of major importance for the resulting release patterns. Based on the obtained knowledge the selection of an appropriate release medium for in vitro tests simulating in vivo conditions can be facilitated, and "stress tests" can be developed allowing to get rapid feedback on the release characteristics of a specific batch.

Antimetabolites, Antineoplastic↗

How porosity and size affect the drug release mechanisms from PLGA-based microparticles.

Porous, poly(lactic-co-glycolic acid) (PLGA)-based microparticles were prepared using a water-in-oil-in-water (W/O/W) solvent extraction/evaporation technique. Lidocaine was used as a model drug and different-sized particle fractions were obtained by sieving. The physicochemical properties of the devices and changes thereof upon exposure to phosphate buffer pH 7.4 were studied using optical and scanning electron microscopy, size exclusion chromatography (SEC), differential scanning calorimetry (DSC), gravimetric analysis and in vitro drug release measurements. In contrast to non-porous microparticles of identical composition, the relative drug release rate was found to decrease with increasing system size. SEC, DSC and gravimetric analysis showed that the degradation rate of the polymer increased with increasing microparticle dimension, indicating that autocatalytic effects play an important role even in small and highly porous PLGA-based microparticles. However, these effects were much less pronounced than in non-porous devices. Importantly, they were overcompensated by the effects of the increasing diffusion pathway lengths with increasing system dimension. Thus, high initial microparticle porosities do not only lead to increased drug mobilities, but can also fundamentally alter the underlying mass transport mechanisms.

Catalysis↗

Drug release from lipid-based implants: elucidation of the underlying mass transport mechanisms.

The aim of this study was to better understand the mass transport mechanisms involved in the control of drug release from lipid-based implants. Different types of triglyceride-based cylinders were prepared by compression. Glycerol-trilaurate, -trimyristate, -tripalmitate and -tristearate were used as model lipids, lysozyme and pyranine as model drugs. The effects of several formulation and processing parameters on the resulting drug release kinetics in phosphate buffer pH 7.4 were studied and the obtained results analyzed using Fick's second law of diffusion. Interestingly, lysozyme release from implants prepared by compression of a lyophilized emulsion (containing dissolved drug and lipid) was found to be purely diffusion-controlled, irrespective of the type of triglyceride. In contrast, the dominating release mechanism depended on the type of lipid in the case of pyranine-loaded implants prepared by compression of a lyophilized lipid-drug solution: with glycerol-trilaurate and -tristearate the systems were found to be purely diffusion-controlled, whereas also other mass transport phenomena are of importance in glycerol-trimyristate and -tripalmitate-based devices. Similarly, changes in the size of the compressed lipid-drug particles, drug loading and compression force significantly affected the underlying release mechanisms. The addition of a drug-free, poly(lactic-co-glycolic acid) (PLGA)-based coating around the implants delayed the onset of pyranine release for about 20 days. Interestingly, the subsequent drug release was purely diffusion-controlled, irrespective of the type of triglyceride. Also the addition of different amounts (and particle size fractions) of saccharose to pyranine-loaded implants led to purely diffusion-controlled drug release.

Arylsulfonates↗

Paclitaxel-loaded microparticles and implants for the treatment of brain cancer: preparation and physicochemical characterization.

The aim of this study was to prepare different types of paclitaxel-loaded, PLGA-based microparticles and lipidic implants, which can directly be injected into the brain tissue. Releasing the drug in a time-controlled manner over several weeks, these systems are intended to optimize the treatment of brain tumors. The latter is particularly difficult because of the blood-brain barrier (BBB), hindering most drugs to reach the target tissue upon systemic administration. Especially paclitaxel (being effective for the treatment of ovarian, breast, lung and other cancers) is not able to cross the BBB to a notable extent since it is a substrate of the efflux transporter P-glycoprotein. Both, biodegradable microparticles as well as small, cylindrical, glycerol tripalmitate-based implants (which can be injected using standard needles) were prepared with different paclitaxel loadings. The effects of several formulation and processing parameters on the resulting drug release kinetics were investigated in phosphate buffer pH 7.4 as well as in a diethylnicotinamide (DENA)/phosphate buffer mixture. Using DSC, SEM, SEC and optical microscopy deeper insight into the underlying drug release mechanisms could be gained. The presence of DENA in the release medium significantly increased the solubility of paclitaxel, accelerated PLGA degradation, increased the mobility of the polymer and drug molecules and fundamentally altered the geometry of the systems, resulting in increased paclitaxel release rates.

Antineoplastic Agents, Phytogenic↗

Blends of aqueous polymer dispersions used for pellet coating: importance of the particle size.

Blends of aqueous dispersions of a water-insoluble and an enteric polymer, namely ethyl cellulose:hydroxypropyl methylcellulose acetate succinate (EC:HPMCAS) and ethyl cellulose:methacrylic acid ethyl acrylate copolymer (EC:Eudragit L), were used as coating materials to control theophylline release from matrix pellets. Varying the polymer blend ratio, broad ranges of drug release patterns were obtained at low as well as at high pH. Interestingly, the resulting release profiles were rather similar for both types of blends in 0.1 M HCl, whereas significant differences were observed in phosphate buffer pH 7.4. Surprisingly, drug release at high pH was much slower for EC:HPMCAS blends compared to EC:Eudragit L blends, although HPMCAS leached out more rapidly (and to a higher extent) from the film coatings than Eudragit L. To explain these phenomena and to better understand the underlying drug release mechanisms, thin polymeric films of identical composition as the pellet coatings were prepared and physicochemically characterized before and upon exposure to the release media. Importantly, the polymer particle size was identified to be a very crucial formulation parameter, determining the resulting film coating structure and properties. The Eudragit L particles are much smaller than the HPMCAS particles (nano- vs. micrometer size range) and, thus, more effectively hinder the formation of a continuous and mechanically stable EC network. Consequently, the EC structures remaining after enteric polymer leaching at high pH are mechanically much weaker in the case of Eudragit L. Upon exposure to phosphate buffer, water-filled cracks are formed, through which the drug rapidly diffuses out. In contrast, the EC structures remaining upon HPMCAS leaching are mechanically stronger and drug release is controlled by diffusion through the polymeric remnants.

Cellulose↗

Polymer blends used for the aqueous coating of solid dosage forms: importance of the type of plasticizer.

The aim of this study was to investigate the importance of the type of plasticizer in polymer blends used for the coating of solid dosage forms, comparing a lipophilic and a hydrophilic plasticizer (dibutyl sebacate (DBS) and triethyl citrate (TEC)). In vitro drug release from propranolol hydrochloride (propranolol HCl)-loaded pellets coated with blends of ethyl cellulose (EC) and Eudragit L (100:0, 75:25, 50:50, 25:75 and 0:100 w/w) was investigated at low as well as at high pH. To better understand the underlying mass transport mechanisms, the physicochemical properties of the film coatings (e.g. mechanical resistance, water uptake and dry weight loss behavior) were determined. Interestingly, drug release strongly depended on the type of plasticizer. Importantly, not only the slope but also the shape of the release curves was affected, indicating that the chemical nature of the plasticizer plays a major role for the underlying drug release mechanisms. Diffusion through the intact polymer coatings and/or through water-filled cracks was found to be dominating for the control of drug release. The relative importance of these pathways strongly depended on the polymer blend ratio and type of plasticizer. In contrast to DBS, TEC rapidly leached out of the coatings, resulting in decreasing mechanical resistances of the films and, thus, facilitated crack formation. In addition, the hydrophilicity of the plasticizer significantly affected the water uptake behavior of the film coatings and, hence, changes in the coatings' toughness and drug permeability. Also the relative affinity of the plasticizer to the different polymers was found to be of significance. In contrast to TEC, DBS has a higher affinity to EC than to Eudragit L, resulting in potential redistributions of this plasticizer within the polymeric systems and changes in the release profiles during storage. Importantly, these effects could be avoided with appropriate curing conditions and preparation techniques for the coating dispersions.

Delayed-Action Preparations↗

Effect of the size of biodegradable microparticles on drug release: experiment and theory.

The aim of this study was to investigate the effect of the size of biodegradable microparticles (monolithic dispersions) on the release rate of an incorporated drug in a quantitative way. 5-Fluorouracil-loaded, poly(lactic-co-glycolic acid)-based microparticles were prepared with a solid-in-oil-in-water solvent extraction technique. In vitro drug release from different-sized particle fractions was measured in phosphate buffer pH 7.4. Differential scanning calorimetry (DSC), scanning electron microscopy (SEM) and size exclusion chromatography (SEC) were used to monitor the degradation behavior of the polymer and morphological changes of the microparticles upon exposure to the release medium. Based on these experimental results, an appropriate mathematical theory was identified and used to get further insight into the underlying physical and chemical processes, which are involved in the control of drug release. Interestingly, the relative as well as the absolute release rate of the drug increased with increasing microparticle radius, despite of the increasing diffusion pathways. SEC, DSC and SEM analysis revealed that the degradation behavior of the matrix forming polymer was not significantly affected by the size of the devices and that autocatalytic effects do not seem to play a major role. Importantly, the initial drug loading significantly increased with increasing radius of the drug delivery system. Thus, large microparticles became more porous during drug release than small microparticles, leading to higher apparent diffusivities and drug transport rates. This effect overcompensated the effect of the increasing diffusion pathways with increasing microparticle radius, resulting in increased drug release rates with increasing device dimension. The applied mathematical model, considering drug diffusion with non-constant diffusivities (to account for polymer degradation) was able to quantitatively describe the observed drug release patterns. Importantly, an exponential relationship could be established between the diffusion coefficient and the initial loading of the drug. Based on this dependency, it was possible to predict the resulting drug release kinetics for arbitrary microparticle sizes in a quantitative way.

Biotransformation↗

Blends of enteric and GIT-insoluble polymers used for film coating: physicochemical characterization and drug release patterns.

THE OBJECTIVES OF THIS STUDY WERE: (i). to use blends of gastrointestinal tract (GIT)-insoluble and enteric polymers (ethyl cellulose and Eudragit L) as coating materials for multiparticulate controlled release dosage forms; (ii). to investigate the effects of the polymer blend ratio and coating level on the resulting drug release patterns; and (iii). to explain the observed phenomena based on the physicochemical properties of the systems. Propranolol HCl-loaded pellets were coated in a fluidized bed coater with organic polymer solutions; thin, drug-containing and drug-free, polymeric films were prepared using a casting knife. In vitro drug release, water uptake and dry weight loss studies were performed in 0.1 M HCl and phosphate buffer pH 7.4, respectively. The apparent drug diffusion coefficients within the polymeric systems were determined using different experimental and theoretical techniques (side-by-side diffusion cells, in vitro drug release from thin films; exact and approximate solutions of Fick's second law of diffusion). A broad range of drug release patterns from coated pellets could be achieved by varying the GIT-insoluble:enteric polymer blend ratio. With increasing relative amounts of Eudragit L, the release rates in both media significantly increased. The increase at low pH could be attributed to an increase in water uptake, as observed with thin films. Interestingly, only partial Eudragit L leaching occurred in phosphate buffer pH 7.4 even at high enteric polymer contents, indicating that the GIT-insoluble polymer effectively hindered the dissolution of the entrapped Eudragit L. At high pH, both polymer leaching and polymer swelling contributed to the control of drug release. The determined apparent drug diffusion coefficients take the two effects adequately into account.

Cellulose↗

Non-degradable microparticles containing a hydrophilic and/or a lipophilic drug: preparation, characterization and drug release modeling.

Non-degradable microparticles based on ammonio methacrylate copolymers (Eudragit RS:RL 4:1 blends) containing the hydrophilic drug propranolol HCl and/or the lipophilic drug nifedipine were prepared with an oil-in-water (O/W) and a water-in-oil-in-water (W/O/W) solvent evaporation technique. Both drugs were successfully incorporated separately as well as simultaneously. In all cases, the resulting release rate(s) of the drug(s) was/were found to be controlled over periods of at least 8 h. To elucidate the underlying mass transport mechanisms, the microparticles were thoroughly characterized by X-ray powder diffractometry, differential scanning calorimetry, particle size analysis, and determination of the actual drug loading(s). Analytical solutions of Fick's second law of diffusion considering non-steady state conditions were used to describe the release of propranolol HCl. Interestingly, the resistance for drug release within the unstirred liquid boundary layers on the surfaces of the microparticles was found to be negligible compared to the diffusional resistance within the polymeric devices. Importantly, the mathematical theories could be used to normalize the experimentally determined in vitro drug release with respect to the microparticle size. Thus, the effect of the type of preparation method (O/W vs. W/O/W) and device composition (polymer blend plus one drug only vs. polymer blend plus drug combination) on the diffusional resistance within the microparticles could be studied. In addition, further insight into the occurring mass transport processes was gained. For example, the time-dependent evolution of the drug concentration profiles within the microparticles upon exposure to the release medium could be calculated. An interesting practical application of the mathematical theories is the possibility to predict the effect of different formulation parameters on the resulting drug release patterns, e.g. the effect of the microparticle size.

Chemistry, Pharmaceutical↗

Floating matrix tablets based on low density foam powder: effects of formulation and processing parameters on drug release.

The aim of this study was to develop and physicochemically characterize single unit, floating controlled drug delivery systems consisting of (i). polypropylene foam powder, (ii). matrix-forming polymer(s), (iii). drug, and (iv). filler (optional). The highly porous foam powder provided low density and, thus, excellent in vitro floating behavior of the tablets. All foam powder-containing tablets remained floating for at least 8 h in 0.1 N HCl at 37 degrees C. Different types of matrix-forming polymers were studied: hydroxypropyl methylcellulose (HPMC), polyacrylates, sodium alginate, corn starch, carrageenan, gum guar and gum arabic. The tablets eroded upon contact with the release medium, and the relative importance of drug diffusion, polymer swelling and tablet erosion for the resulting release patterns varied significantly with the type of matrix former. The release rate could effectively be modified by varying the "matrix-forming polymer/foam powder" ratio, the initial drug loading, the tablet geometry (radius and height), the type of matrix-forming polymer, the use of polymer blends and the addition of water-soluble or water-insoluble fillers (such as lactose or microcrystalline cellulose). The floating behavior of the low density drug delivery systems could successfully be combined with accurate control of the drug release patterns.

Chemistry, Pharmaceutical↗

Mathematical modeling of drug release from bioerodible microparticles: effect of gamma-irradiation.

Bioerodible polymers used in controlled drug delivery systems, such as poly(lactic-co-glycolic acid) (PLGA) undergo radiolytic degradation during gamma-irradiation. In spite of the considerable practical importance, yet only little knowledge is available on the consequences of this sterilization method on the resulting drug release patterns in a quantitative way. The major objectives of the present study were: (i) to monitor the effects of different gamma-irradiation doses on the physicochemical properties of drug-free and drug-loaded, PLGA-based microparticles; (ii) to analyze the obtained experimental results using adequate mathematical models; (iii) to get further insight into the occurring physical and chemical phenomena; and (iv) to relate the applied gamma-irradiation dose in a quantitative way to the resulting drug release rate. 5-Fluorouracil-loaded, PLGA-based microparticles were prepared with an oil-in-water solvent extraction method and exposed to gamma-irradiation doses ranging from 0 to 33 kGy. Size exclusion chromatography, differential scanning calorimetry, scanning electron microscopy, particle size analysis, determination of the actual drug loading and in vitro drug release kinetics were used to study the effects of the gamma-irradiation dose on the physicochemical properties of the microparticles. Two mathematical models-a simplified and a more comprehensive one-were used to analyze the experimental results. The simplified model considers drug diffusion based on Fick's second law for spherical geometry and a Higuchi-like pseudo-steady-state approach. The complex model combines Monte Carlo simulations (describing polymer erosion) with partial differential equations quantifying drug diffusion with time-, position- and direction-dependent diffusivities. Interestingly, exponential relationships between the gamma-irradiation dose and the initial drug diffusivity within the microparticles could be established. Based on this knowledge both models were used to predict the resulting drug release kinetics as a function of the gamma-irradiation dose. Importantly, the theoretical predictions were confirmed by experimental results.

Dose-Response Relationship, Radiation↗

Pharmaceutical applications of shellac: moisture-protective and taste-masking coatings and extended-release matrix tablets.

Shellac is a natural polymer, which is used as enteric coating material in pharmaceutical applications. The major objective of the present study was to investigate the potential of shellac for other purposes, namely to provide moisture-protective and taste-masking coatings as well as extended-release matrix tablets. The efficiency of shellac to achieve moisture protection and taste masking was compared with that of hydroxypropyl methylcellulose (HPMC), which is most frequently used for these purposes. Shellac-coated tablets showed lower water uptake rates than HPMC-coated systems at the same coating level. The stability of acetylsalicylic acid was higher in tablets coated with shellac compared with HPMC-coated systems, irrespective of the storage humidity. Therefore, lower shellac coating levels were required to achieve the same degree of drug protection. Shellac coatings effectively masked the unpleasant taste of acetaminophen tablets. Compared to HPMC, again lower coating levels were required to achieve similar effects. The resulting drug release in simulated gastric fluid was not significantly altered by the thin shellac coatings, which rapidly ruptured due to the swelling of the coated tablet core. In addition, shellac was found to be a suitable matrix former for extended-release tablets. The latter could be prepared by direct compression or via wet granulation using ethanolic or ammoniated aqueous shellac binder solutions. The resulting drug-release patterns could effectively be altered by varying different formulation and processing parameters.

Acetaminophen↗

The effect of gamma-irradiation on drug release from bioerodible microparticles: a quantitative treatment.

The two major objectives of this study were: (i) to monitor the effect of different gamma-irradiation doses (4-33 kGy) on the release kinetics from 5-fluorouracil (5-FU)-loaded poly(D,L-lactide-co-glycolide) (PLGA)-based microparticles, and (ii) to analyze the obtained experimental data with a new mathematical model giving insight into the occurring mass transport phenomena. Drug release was found to depend significantly on the applied gamma-irradiation dose. Interestingly, the obtained release profiles were all biphasic: a rapid initial drug release phase ("burst") was followed by a slower, approximately constant drug release phase. Surprisingly, only the initial rapid drug release was accelerated by gamma-irradiation; the subsequent zero-order phase was almost unaffected. Importantly, the new mathematical model which is based on Fick's second law of diffusion and which considers polymer degradation was applicable to all the investigated systems. In addition, the gamma-irradiation dose could be quantitatively related to the resulting drug release rate. In conclusion, diffusion seems to be the dominating release rate controlling mechanism in all cases, with a significant contribution of the polymer degradation process.

Antimetabolites, Antineoplastic↗

Floating microparticles based on low density foam powder.

The aim of this study was to develop a novel multiparticulate gastroretentive drug delivery system and to demonstrate its performance in vitro. Floating microparticles consisting of (i) polypropylene foam powder; (ii) verapamil HCl as model drug; and (iii) Eudragit RS, ethylcellulose (EC) or polymethyl methacrylate (PMMA) as polymers were prepared with an O/W solvent evaporation method. The effect of various formulation and processing parameters on the internal and external particle morphology, drug loading, in vitro floating behavior, in vitro drug release kinetics, particle size distribution and physical state of the incorporated drug was studied. The microparticles were irregular in shape and highly porous. The drug encapsulation efficiency was high and almost independent of the theoretical loading. Encapsulation efficiencies close to 100% could be achieved by varying either the ratio 'amount of ingredients: volume of the organic phase' or the relative amount of polymer. In all cases, good in vitro floating behavior was observed. The release rate increased with increasing drug loading and with decreasing polymer amounts. The type of polymer significantly affected the drug release rate, which increased in the following rank order: PMMA<EC<Eudragit RS. A broad spectrum of release patterns could be obtained with the investigated formulations. In contrast, the effect of the volume of the aqueous phase on drug release was not very pronounced. The size of the microparticles was almost independent of the drug loading, but strongly depended on the amount of polymer. The drug was partly dissolved and partly in the amorphous form distributed throughout the system.

Drug Compounding↗