PubMed Health⌕ Search

Biomedical subjects

J Silcox

Publications and source records attributed to J Silcox.

14 recordsLinked to original sources

Separation of bulk and surface-losses in low-loss EELS measurements in STEM.

To identify major features in low electron energy loss spectra, the different excitations (bulk plasmons, interband transitions, surface plasmons, Cherenkov and surface guided modes) must be delineated from each other. In this paper, this process is achieved by noting the linear thickness dependence of bulk processes contrasted with the constant thickness behavior of surface excitations. An alternative approach of analyzing bulk plasmon-loss is also introduced. Using a new algorithm, the parameters of plasma generation-plasmon energy E(P,0), a damping parameter DeltaE(P) and the coefficient of the dispersion relation gamma were obtained from a single curve fitting on the example of Si. The ability to separate surface-losses from the rest of the data permitted identification of the fine structure of the surface-losses. The strong peak at 8.2 eV characteristic of non-radiative surface plasmon excitations was measured for Si. Analysis of surface excitations indicates that a 10ASiO2 surface coating layer is still present despite careful cleaning the specimen. Dielectric functions deduced from the EELS data prove to be considerably affected by the presence of the surface-losses for samples as thick as 800A.

Journal Article↗

Direct determination of local lattice polarity in crystals.

With current advances in sub-angstrom resolution scanning transmission electron microscopy (STEM), it is now possible to image directly local crystal structures of materials where dramatically different atoms are separated from each other at distances about or less than 1 angstrom. We achieved direct imaging of atomic columns of nitrogen in close proximity to columns of aluminum in wurtzite aluminum nitride by using annular dark field imaging in an aberration-corrected STEM. This ability allows direct determination of the local polarity in nanoscale crystals and crystal defects.

Journal Article↗

Full recovery of electron damage in glass at ambient temperatures.

An unusually complete recovery of extensive electron-beam-induced damage in a thin film of a CaO-Al2O3-SiO2 glass was discovered. Nanoscale measurements show that the Ca ions migrate about 10 nm away during irradiation and return during recovery. Oxygen atoms are trapped largely as molecular oxygen and do not migrate. Electron energy loss measurements demonstrate that the glass returns completely to the original compositional and structural state thus indicating that the glass is in a deep thermodynamic energy minimum.

Journal Article↗

Simulation of thermal diffuse scattering including a detailed phonon dispersion curve.

Thermal vibration of the atoms in a crystal give rise to a diffuse background in the diffraction pattern (in between the normal allowed Bragg reflections). The Einstein model for phonon vibrations in a crystal leads to Gaussian statistics for the phonons. However, the Einstein model ignores the possibility of correlation between the atoms. An accurate model of the phonon dispersion curves for silicon is used to generate a set of more accurate random atomic displacements. These displacements are used in a multislice-style simulation to gauge the validity of the Einstein approximation. The phonon dispersion curve yields a small additional oscillatory structure in the thermal diffuse scattering (TDS) pattern. This does not produce significant changes in the annular dark field scanning transmission electron microscope (ADF-STEM) image signal, but could have a large impact on convergent beam measurements of bond charges.

Journal Article↗

Annular dark-field image simulation of the YBa2Cu3O(7-delta)/BaF2 interface

Scanning transmission electron microscope (STEM) images of the interface of a YBa2Cu3O(7-delta) (YBCO)/BaF2 thin film bilayer show a relatively wide (approximately 40 A) contrasting band at the interface when viewed edge-on. Simulation of annular dark-field (ADF) images of this interface reveal that a significant contribution to this wide band of contrast is due to strain from dislocations oriented perpendicular to the incident beam direction and this contrast cannot be explained using solely a Z-contrast interpretation of ADF images. We believe that these are the first such calculations which predict that the presence of a misfit dislocation network can contribute a significant amount of contrast to cross-section ADF images of an interface.

Journal Article↗

Subnanometer-Diameter Wires Isolated in a Polymer Matrix by Fast Polymerization

The preparation and analysis of inorganic-organic polymer nanocomposites consisting of inorganic nanowires and multiwire "cables" in a random-coil organic polymer host is reported. Dissolution of inorganic (LiMo3Se3)n wires in a strongly coordinating monomer, vinylene carbonate, and the use of a rapid polymerization in the presence of a cross-linking agent produce nanocomposites without phase separation. Polymerization of dilute solutions yields a material containing mostly (Mo3Se3(-))n mono- and biwires, 6 to 20 angstroms in diameter and 50 to 100 nanometers long. Polymerization of more concentrated liquid crystalline solutions yields a nanocomposite containing oriented multiwire cables, 20 to 40 angstroms in diameter and up to 1500 nanometers long, that display optical anisotropy and electrical conductivity.

Journal Article↗

Transfer of carbetocin into human breast milk.

OBJECTIVE: To study the transfer of carbetocin into human breast milk. METHODS: Five healthy nursing women, 7-14 weeks postpartum, emptied their breasts using a breast pump and then received 70 micrograms carbetocin by intramuscular injection. Using a radioimmunoassay, the concentrations of carbetocin were measured in plasma and breast milk samples obtained before carbetocin administration and at 15, 30, 60, 90, 120, and 240 minutes after drug administration. RESULTS: For plasma, the mean (+/- standard deviation) area under the curve (AUC) of carbetocin versus time was 1119.3 +/- 315.9 pg/mL, a value about 50 times higher than the mean AUC for carbetocin in breast milk (18.6 +/- 13.7 and 29.0 +/- 23.8 pg/mL for the right and left breast, respectively). The ratio of milk to plasma AUC was low: 1.7 +/- 0.9 and 3.1 +/- 2.8% for the left and right breast, respectively. No serious adverse reactions occurred and no clinically significant changes in vital signs were found. CONCLUSION: Very little carbetocin is transferred into human breast milk, presenting little risk to breast-fed infants.

Adult↗