Publications and source records attributed to J Silny.

At least 19 recordsLinked to original sources

[Chiparray-based identification of gene expression in HUVECs treated with low frequency electric fields].

PURPOSE: After high-voltage electric injury, patients often show progressive tissue necrosis and thrombosis of blood vessels even remote from the entry and exit sites of electrical current. Recently, we were able to demonstrate IN VIVO and VITRO the release of several prothrombotic factors. In this study, we report on IN VITRO studies performed to characterize gene expression profiles using a DNA-microarray in HUVECs (human umbilical vein endothelial cells) exposed to low frequency electrical current. METHODS: HUVECs were plated and grown to confluence in a culture chamber. They were exposed to 25 periods of 50 Hz sinusoidal waves. The periods had field strength of 60 V/cm and duration of 100 ms. Periods were interrupted by 10-second intervals to prevent significant joule heating. Control HUVECs were treated identically except that no electric field was applied. Samples from control and treated cells were taken after six and 24 hours. A PIQOR Immunology Array (Milteny Biotech) containing 1076 cDNAs was used for gene expression analysis. Hybridization of Cy3- and Cy5-labelled samples, image capture, and signal quantification of hybridized arrays were performed. Local background was subtracted from the signal to obtain the net signal intensity and the ratio of Cy5/Cy3. The ratios were normalized to the median of all ratios and the mean of the ratios of four corresponding spots was computed. More than two-fold increases or decreases of the gene expression were regarded as relevant. RESULTS: A total of 413 genes (1s + s) respectively 345 genes (2s + s) could be detected. The results obtained display a distinct expression pattern of up-regulated genes known to be important for hemostasis (e.g. UPA, UPAR, ECE1, PAFAH1B1, PGT, INOS, ENOS, TPA, ICAM1, VCAM1, PAI1, PAI2, VWF, PTGDR, F3, THBD), which was most evident after 24 hours. This expression profile might lead to a hypercoagulated state. Furthermore, the expression of genes involved in angiogenesis was reduced whereas the expression of those involved in platelet formation was increased. CONCLUSION: Our results indicate that low frequency electrical fields induce a distinct signature of differential gene expression in exposed HUVECs. This might explain the clinical observation of thrombosis and progressive tissue necrosis after electrical injury.

Blood Coagulation↗

Duodenal motility is not affected during duodenotomy in pigs.

The effects of surgical procedures on intestinal motility are still under debate. In order to quantify the effects of duodenotomy on duodenal motility, the present study used the electric impedance technique (IMP). Ten pigs (32-40 kg) were instrumented under general anaesthesia with a central venous catheter (CVC) and a percutaneous enterogastrostomy (PEG). Duodenal phases I-III and the duration of the migrating motor complex (MMC) were measured by an IMP catheter, which was introduced non-invasively into the proximal duodenum via the PEG by endoscopy, or through surgical placement in an invasive manner via duodenotomy. There were no significant differences in the length of interdigestive phases I-III between the groups. In tendency, pigs after laparotomy and duodenotomy demonstrated slightly prolonged median duration of phase I (P = 0.1) and phase III (P = 0.7), while phase II (P = 0.1) and the MMC cycle length (P = 0.6) seemed to be shortened as compared to pigs of the PEG group. In conclusion, simple laparotomy with duodenotomy did not affect the proximal duodenal motility activity measured by the impedance technique.

Animals↗

Evaluation and comparison of 50 Hz current threshold of electrocutaneous sensations using different methods.

Leakage currents, tiny currents flowing from an everyday-life appliance through the body to the ground, can cause a non-adequate perception (called electrocutaneous sensation, ECS) or even pain and should be avoided. Safety standards for low-frequency range are based on experimental results of current thresholds of electrocutaneous sensations, which however show a wide range between about 50 microA (rms) and 1000 microA (rms). In order to be able to explain these differences, the perception threshold was measured repeatedly in experiments with test persons under identical experimental setup, but by means of different methods (measuring strategies), namely: direct adjustment, classical threshold as amperage of 50% perception probability, and confidence rating procedure of signal detection theory. The current is injected using a 1 cm2 electrode at the highly touch sensitive part of the index fingertip. These investigations show for the first time that the threshold of electrocutaneous sensations is influenced both by adaptation to the non-adequate stimulus and individual, emotional factors. Therefore, classical methods, on which the majority of the safety investigations are based, cannot be used to determine a leakage current threshold.The confidence rating procedure of the modern signal detection theory yields a value of 179.5 microA (rms) at 50 Hz power supply net frequency as the lower end of the 95% confidence range considering the variance in the investigated group. This value is expected to be free of adaptation influences, and is distinctly lower than the European limits and supports the stricter regulations of Canada and USA.

Adaptation, Physiological↗

Effects of a single dose of ketamine on duodenal motility activity in pigs.

In order to investigate the effects of a single dose of ketamine on duodenal motility, the present study focused on the electric impedance technique. Five pigs (32 to 40 kg, CVC group) were instrumented with a central venous catheter 1 d before measurements. The next day, general anesthesia was started and maintained via central venous catheter by propofol and fentanyl. In contrast, the pigs of the KETA group (n = 5) received ketamine intramuscularly prior to the induction of anesthesia by the injection of propofol-fentanyl via an ear vein. An intraluminal impedance catheter was manually introduced into the proximal duodenum. Measurements were recorded for 4 h. The KETA group showed a median duration of phase II that was shortened by 35%, while phase I was prolonged by 73% (P < 0.05). In conclusion, when gastrointestinal motility has to be investigated, the effects of a single dose of ketamine, even for premedication, should be taken into consideration.

Anesthetics, Dissociative↗

[Acid and non-acid gastro-esophageal reflux in newborns. Preliminar results using intraluminal impedance].

Preterm infants present often Gastroesophageal refluxes (GER). Esophageal pH monitoring to reflux detection is of limited use in this infants because their gastric pH is normally higher than 4 for 90% of the time. Other methods such as the Intraluminal Impedance Technique (MII) technique and the use of micromanometric catheters try to palliate the difficulties for measuring GER by pH monitoring. The aim of this study, in a first step, was to obtain the normal Intraluminal Impedance values on control children and, in a second step, to study the relationship between GER and cardiorespiratory episodes using simultaneous recording of the end-tidal fraction of expired CO2, 02 saturation by pulse-oximetry, respiratory frequency, esophageal impedance and manometry, gastro-esophageal pHmetry, and electrocardiography in selected patients. Data from simultaneous pH and Intraluminal Impedance during 24 hours in 7 control preterms showed 89 acid refluxes, 192 non-acid refluxes, 79.36% of all refluxes reached the proximal esophagus. Therefore the impedance is an innocuous method which opens new horizons in the study of such a common illness as the GER in the preterm infants.

Body Composition↗

Effects of propofol and fentanyl on duodenal motility activity in pigs.

To investigate the effects of propofol and fentanyl on the postprandial duodenal motility the intraluminal impedance technique was used. Six pigs were instrumented with a central venous catheter, a percutaneous enterogastrostomy (PEG), and an impedance catheter, which was introduced via the PEG into the duodenum through endoscopy. Over the following 3 d, duodenal motility was measured for 8-hour periods. Measurements were taken on each subject under 3 different sets of conditions: in the conscious unrestrained pig, during propofol sedation, and during sedation with propofol-fentanyl. Both, after morning feeding and during gastric nutrition via the PEG, duodenal feeding patterns and duodenal phase II of the migrating motor cycle were shortened during propofol and propofol-fentanyl sedation. In contrast, the duration of phase I was prolonged by propofol and propofol-fentanyl. In conclusion, either propofol or propofolfentanyl sedation shortens duodenal feeding patterns, as well as phase II of the migrating motor cycle.

Animals↗

Impedance characteristics of esophageal motor function in achalasia.

Detailed data on patterns of esophageal bolus transport in patients with achalasia are still lacking. To study these we applied the novel technique of multichannel intraluminal impedance measurements. Ten patients with achalasia were studied using a 16 channel system. Liquid and semisolid boluses of 10 mL were applied with the patients in a supine position. Patterns of bolus transport were determined and analyzed as compared to results obtained from 20 healthy subjects. The healthy subjects featured a unique typical primary peristalsis pattern independent of bolus viscosity. In contrast, achalasia patients demonstrated different impedance characteristics, including: (i) significantly lower baseline esophageal impedance during the resting state as compared with healthy volunteers (999 omega +/- 108 versus 2749 omega +/- 113); (ii) failed bolus transport through the esophagus in all cases; (iii) impedance evidence of luminal content regurgitation in 35% of the swallows (iv) impedance evidence of pathological air movement within the proximal esophagus during deglutition in 38% of the swallows, so called air trapping. Thus, impedance characteristics of achalasia have been defined and can be attributed to known symptoms of achalasia. They can be used as basic findings for further classification of pathological bolus transports in other esophageal motility disorders.

Adult↗

50-Hz magnetic field exposure influences DNA repair and mitochondrial DNA synthesis of distinct cell types in brain and kidney of adult mice.

Despite several recent investigations, the impact of whole-body magnetic field exposure on cell-type-specific alterations due to DNA damage and DNA repair remains unclear. In this pilot study adult mice were exposed to 50-Hz magnetic field (mean value 1.5 mT) for 8 weeks or left unexposed. Five minutes after ending exposure, the mice received [(3)H]thymidine and were killed 2 h later. Autoradiographs were prepared from paraffin sections of brains and kidneys for measuring unscheduled DNA synthesis and mitochondrial DNA synthesis, or in situ nick translation with DNA polymerase-I and [(3)H]dTTP. A significant (P<0.05) increase in both unscheduled DNA synthesis and in situ nick translation was only found for epithelial cells of the choroid plexus. Thus, these two independent methods indicate that nuclear DNA damage is produced by long-lasting and strong magnetic field exposure. The fact that only plexus epithelial cells were affected might point to possible effects of magnetic fields on iron transport across the blood-cerebrospinal fluid barrier, but the mechanisms are currently not understood. Mitochondrial DNA synthesis was exclusively increased in renal epithelial cells of distal convoluted tubules and collecting ducts, i.e., cells with a very high content of mitochondria, possibly indicating increased metabolic activity of these cells.

Animals↗

Relevance of ineffective oesophageal motility during oesophageal acid clearance.

BACKGROUND: Oesophageal clearance of acid reflux consists of an initial volume clearance followed by neutralisation of the acidified mucosa by swallowed saliva (chemical clearance). Ineffective oesophageal motility (IOM), a frequent finding in patients with gastro-oesophageal reflux disease (GORD), has been claimed to underlie prolonged acid clearance by affecting oesophageal emptying and saliva transport. Intraluminal impedance allows non-radiological monitoring of movement of oesophageal liquids. AIMS: To evaluate the relevance of IOM during oesophageal volume and chemical clearance using combined pH impedance measurements. SUBJECTS: Impedance was validated with fluoroscopy to study volume clearance in three healthy subjects. Acid clearance tests were performed in 10 healthy subjects in the upright and supine positions, before and after oesophageal peristaltic disruption with sildenafil 50 mg. METHODS: After instillation of an acid bolus, simultaneous manometry, pH, and impedance were used to study oesophageal motility, chemical clearance, and volume clearance, respectively. RESULTS: Impedance allowed assessment of volume clearance accurately, showing a strong correlation with fluoroscopy (r(2)=0.89). Sildenafil provoked a graded impairment in oesophageal motility in healthy subjects without affecting saliva secretion. In the upright position, volume clearance was slightly prolonged only with severe IOM (>80% abnormal peristaltic sequences). In the supine position, severe IOM significantly prolonged chemical and volume clearance. Moderate IOM (30-80% abnormal peristalsis) had no effect. With normal peristalsis and moderate IOM, clearance times were similar in the upright and supine positions. Severe IOM however had a greater impact on clearance in the supine than in the upright position. CONCLUSION: Ineffective oesophageal motility has little effect on oesophageal clearance during upright acid reflux. With supine reflux, only severe IOM is associated with prolonged oesophageal clearance.

Acids↗

The interference of electronic implants in low frequency electromagnetic fields.

Electronic implants such as cardiac pacemakers or nerve stimulators can be impaired in different ways by amplitude-modulated and even continuous electric or magnetic fields of strong field intensities. For the implant bearer, possible consequences of a temporary electromagnetic interference may range from a harmless impairment of his well-being to a perilous predicament. Electromagnetic interferences in all types of implants cannot be covered here due to their various locations in the body and their different sensing systems. Therefore, this presentation focuses exemplarily on the most frequently used implant, the cardiac pacemaker. In case of an electromagnetic interference the cardiac pacemaker reacts by switching to inhibition mode or to fast asynchronous pacing. At a higher disturbance voltage on the input of the pacemaker, a regular asynchronous pacing is likely to arise. In particular, the first-named interference could be highly dangerous for the pacemaker patient. The interference threshold of cardiac pacemakers depends in a complex way on a number of different factors such as: electromagnetic immunity and adjustment of the pacemaker, the composition of the applied low-frequency fields (only electric or magnetic fields or combinations of both), their frequencies and modulations, the type of pacemaker system (bipolar, unipolar) and its location in the body, as well as the body size and orientation in the field, and last but not least, certain physiological conditions of the patient (e.g. inhalation, exhalation). In extensive laboratory studies we have investigated the interference mechanisms in more than 100 cardiac pacemakers (older types as well as current models) and the resulting worst-case conditions for pacemaker patients in low-frequency electric and magnetic fields. The verification of these results in different practical everyday-life situations, e.g. in the fields of high-voltage overhead lines or those of electronic article surveillance systems is currently in progress. In case of the vertically-oriented electric 50 Hz fields preliminary results show that per 1 kV/m unimpaired electrical field strength (rms) an interference voltage of about 400 microVpp as worst-case could occur at the input of a unipolar ventricularly controlled, left-pectorally implanted cardiac pacemaker. Thus, already a field strength above ca. 5 kV/m could cause an interference with an implanted pacemaker. The magnetic fields induces an electric disturbance voltage at the input of the pacemaker. The body and the pacemaker system compose several induction loops, whose induced voltages rates add or subtract. The effective area of one representing inductive loop ranges from 100 to 221 cm2. For the unfavourable left-pectorally implantated and atrially-controlled pacemaker with a low interference threshold, the interference threshold ranges between 552 and 16 microT (rms) for magnetic fields at frequencies between 10 and 250 Hz. On this basis the occurrence of interferences with implanted pacemakers is possible in everyday-life situations. But experiments demonstrate a low probability of interference of cardiac pacemakers in practical situations. This apparent contradiction can be explained by a very small band of inhibition in most pacemakers and, in comparison with the worst-case, deviating conditions.

Electromagnetic Fields↗

Current density threshold for the stimulation of neurons in the motor cortex area.

The aim of this study was to determine a current density threshold for exciting the motor cortex area of the brain. The current density threshold for excitation of nerve fibres (20 microm in diameter) found in the literature is approximately 1 A/m(2) at frequencies lower than 1 kHz. In consideration of a safety factor of 100, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) recommends to restrict the exposure to 0.01 A/m(2). The electromagnetic stimulation of neurons in the motor cortex is used in the clinical diagnosis of nerve lesions and neuropathy by means of magnetic or electrical transcranial stimulation. Combining medical data from clinical studies and technical specifications of the Magstim Model 200 stimulator, we were able to compute the current density threshold for the excitation of the human motor cortex by means of the finite element method (FEM). A 3D-CAD head model was built on the basis of magnetic resonance imaging (MRI) slices and segmented into four anatomical structures (scalp, skull, brain, and ventricular system) with different conductivities. A current density threshold for the stimulation of the motor cortex area of the upper limbs of 6 and 2.5 A/m(2) at 2.44 kHz and 50 Hz, respectively, was calculated. As these values lie above the recommended ICNIRP values by two orders of magnitude there is no need for lower safety standards with regard to stimulation of the brain.

Central Nervous System Diseases↗

Electrical phosphenes: on the influence of conductivity inhomogeneities and small-scale structures of the orbita on the current density threshold of excitation.

Electrical and magnetic phosphenes, perceptions of light as a result of non-adequate stimulation of the eye by electrical current or magnetic induction, respectively, are one of the cornerstones to justify limit values for extreme low-frequency fields specified by statutory regulations. However, the mechanism and place of action, as well as the excitation threshold, remain unknown until now. We suggest that the origin of phosphene excitation is the synaptic layer of the eye. The current density threshold value for electrical phosphene excitation was numerically quantified for this area on the basis of a detailed geometrical model in original submillimetre resolution and specifically measured conductivities in the LF range. The threshold values found were 1.8 A m-2 at 60 Hz and 0.3 A m-2 at 25 Hz. These values are comparable with values of other excitable tissues. It has been shown that the current density threshold for phosphene generation depends on small-scale structures not taken into account by previous models.

Electric Conductivity↗

Association of apnea and nonacid gastroesophageal reflux in infants: Investigations with the intraluminal impedance technique.

An association of apnea and gastroesophageal reflux (GER) was proposed previously. However, pH metry as the standard diagnostic tool for GER only measures acid reflux (pH < 4). It is difficult to interpret studies in infants with a presumed association between apnea and GER based on pH metry because the buffering effect of feeding may result in predominantly nonacid GER. The aim of this study was to investigate the temporal association of apnea and GER with the pH-independent intraluminal impedance technique (IMP). Infants with recurrent regurgitation or respiratory symptoms suggestive of apnea were investigated simultaneously with IMP, pH monitoring, and polygraphy. IMP patterns, pH, oronasal flow, and chest wall movement were recorded and analyzed. In 22 infants, 364 GER episodes were recorded by IMP. One hundred and sixty five apneas were documented by visual validation of polygraph records. Forty-nine apneas (29.7%) were associated with GER; 11 (22.4%) of these showed acid reflux (pH < 4). A significant correlation between the time spent apneic and GER was found (P < 0.001). There is marked association between apnea and gastroesophageal reflux in infants. Patients potentially at risk cannot be reliably identified by pH metry. Its exclusive use is therefore not suitable for the detection of all GER-associated apneas in infants. The pH-independent intraluminal impedance technique has proven to be a sensitive diagnostic tool for this approach.

Apnea↗

Acid, nonacid, and gas reflux in patients with gastroesophageal reflux disease during ambulatory 24-hour pH-impedance recordings.

BACKGROUND & AIMS: Gastroesophageal reflux can be acid, nonacid, pure liquid, or a mixture of gas and liquid. We investigated the prevalence of acid and nonacid reflux and the air-liquid composition of the refluxate in ambulant healthy subjects and patients with reflux disease (GERD). METHODS: Twenty-four-hour ambulatory recordings were performed in 30 patients with symptomatic GERD and erosive esophagitis and in 28 controls. Esophageal pH and impedance were used to identify acid reflux (pH drop below 4.0), minor acid reflux (pH drop above 4.0), nonacid reflux (pH drop less than 1 unit + liquid reflux in impedance), and gas reflux. RESULTS: The total rate of gastroesophageal reflux episodes was similar in patients and controls. Patients with GERD had a higher proportion (45% vs. 33%) and rate of acid reflux than controls (21.5 [9-35]/24 h vs. 13 [6.5-21]/24 h; P < 0.05). One third of reflux events was nonacid in both groups. Mixed reflux of gas and liquid was the most frequent pattern with gas preceding liquid in 50%-80% of cases. Pure liquid reflux was more often acid in patients with GERD than controls (45% vs. 32%; P < 0.05). CONCLUSIONS: Reflux of gastric contents was similarly frequent in patients with GERD and controls. Although there was no difference in the overall number of reflux episodes, more acidic reflux occurred in symptomatic patients with GERD, suggesting differences in gastric acid secretion or distribution.

Adult↗

A model of the electrical volume conductor in the region of the eye in the ELF range.

Electrical and magnetic phosphenes are irritations of the eye caused by electric currents or magnetic fields. These are well known effects initially investigated in the early 1900s. Available estimations of the current densities in the eye, based on the assumption of a homogeneous volume conductor, show low thresholds. These outdated thresholds are still an important cornerstone when justifying today's limit values for extremely low-frequency (ELF) fields specified by statutory regulations. In vitro measurements of the complex conductivity of cattle eye are carried out for the ELF range (5-2000 Hz) separated for the different tissues of the eyeball. They do not show peculiarities at 20 Hz which is the threshold minimum for the phosphene generation. The reported conductivity data of the eye region show variations of two orders of magnitude regarding the electrical conductivity of the individual tissue layers. Starting with these new data, a model of the orbita is introduced describing the eye and its periphery as an electrically inhomogeneous volume conductor. This model contains small-scale structures which are expected to behave as good electrical conductors yielding regions of higher field values within the eye. Therefore, earlier models assuming a homogeneous volume conductor can be regarded as oversimplistic.

Animals↗

Composition of the postprandial refluxate in patients with gastroesophageal reflux disease.

OBJECTIVE: It is not known whether the characteristics of the postprandial refluxate in patients with gastroesophageal reflux disease (GERD) differ from those observed in normal subjects. The aim of this study was to characterize the postprandial refluxate in adult patients with GERD using combined intraluminal electrical impedance and pH measurements. METHODS: Postprandial gastroesophageal reflux was assessed in 16 patients with GERD and 15 controls. pH and intraluminal electrical impedance were used to identify acid and nonacid reflux of liquid, mixed (liquid + gas) or gas. RESULTS: Transient lower esophageal sphincter relaxations (TLESRs) and reflux of gastric contents were equally frequent in both groups. However, patients with GERD had more acid reflux [8 (4.7-10.5)/h vs 3.5 (2.6-6)/h, p < 0.05], and normal subjects had more nonacid reflux [5 (4.3-6.7)/h is 3 (1-3.5)/h, p < 0.05]. Gas reflux was less frequent in GERD than in controls (51% vs 68%; p < 0.05). Pure liquid reflux, however, was more frequent (40% vs 26%, p < 0.05) and twice as likely to be acid in GERD. During TLESRs, liquid acid reflux was more frequent in GERD than in controls. CONCLUSIONS: TLESRs and reflux of gastric contents are similarly frequent in patients with GERD and controls. However, patients with GERD have more acid reflux and less nonacid reflux. Differences in the air-liquid composition of the refluxate may contribute to the higher rate of acid reflux observed in these patients.

Acids↗

A marker-based measurement procedure for unconstrained wrist and elbow motions.

A protocol is proposed to obtain the joint angles of wrist and elbow from tracked triads of surface markers on each limb segment. Cuffs placed on the limb support the rigidity of the triads. Additional markers are used to mark the approximate positions of joints. Corrections of surface marker data for skin motion are derived from a priori knowledge about plausible joint motions. In addition, ill-conditioned states are trapped when the elbow is nearly fully extended. The protocol is applied to sample motions which demonstrate the use and the effect of the corrections. The results show that the model assumptions are reasonable and that accurate joint rotations can be obtained. The correction steps prove to be an essential part of upper-extremity movement analysis.

Adult↗

Non-invasive detection of the single motor unit action potential by averaging the spatial potential distribution triggered on a spatially filtered motor unit action potential.

For research as well as diagnostic applications the non-invasive detection of the activity of single motor units is of interest. The most direct information is expected to be found in monopolarly recorded data. But when an array of surface electrodes is used for the monopolar recordings of the potential distribution on the skin, in most cases an additional invasive needle electrode is utilized to detect the exact points in time when a certain motor unit is firing. With this supplementary information, an averaging of the monopolar EMG tracings can be performed. In this paper, a completely non-invasive methodology is presented which replaces the invasive needle by a spatial filtering procedure. The EMG signals from the m. biceps brachii are recorded monopolarly with an electrode array. Afterwards, a spatial filtering procedure, called normal double differentiating filter, is applied to the data. The EMG signals obtained are investigated by means of an amplitude threshold to distinguish the activity of different motor units. The point of the maximum amplitude of the selected peaks then is used as trigger point to average the monopolar EMG data. The time courses of the motor unit action potential signals found after applying the described procedure show similar shapes, while two different components are to be identified: corresponding to the spread of the excitation, one is referring to stationary, the other to travelling events. These results justify the possibility to replace the needle electrode to obtain a trigger event in the future by the non-invasive spatial filtering procedure.

Action Potentials↗