Quantitative 1H-magnetic resonance spectroscopy of human brain: Influence of composition and parameterization of the basis set in linear combination model-fitting.

Localized short-echo-time (1)H-MR spectra of human brain contain contributions of many low-molecular-weight metabolites and baseline contributions of macromolecules. Two approaches to model such spectra are compared and the data acquisition sequence, optimized for reproducibility, is presented. Modeling relies on prior knowledge constraints and linear combination of metabolite spectra. Investigated was what can be gained by basis parameterization, i.e., description of basis spectra as sums of parametric lineshapes. Effects of basis composition and addition of experimentally measured macromolecular baselines were investigated also. Both fitting methods yielded quantitatively similar values, model deviations, error estimates, and reproducibility in the evaluation of 64 spectra of human gray and white matter from 40 subjects. Major advantages of parameterized basis functions are the possibilities to evaluate fitting parameters separately, to treat subgroup spectra as independent moieties, and to incorporate deviations from straightforward metabolite models. It was found that most of the 22 basis metabolites used may provide meaningful data when comparing patient cohorts. In individual spectra, sums of closely related metabolites are often more meaningful. Inclusion of a macromolecular basis component leads to relatively small, but significantly different tissue content for most metabolites. It provides a means to quantitate baseline contributions that may contain crucial clinical information.

Adolescent↗

Characterization of the macromolecule baseline in localized (1)H-MR spectra of human brain.

Short-echo-time magnetic resonance spectra of human brain contain broad contributions from macromolecules. As they are a priori of unknown shape and intensity, they pose a problem if one wants to quantitate the overlying spectral features from low-molecular-weight metabolites. On the other hand, the macromolecular contributions may provide relevant clinical information themselves, if properly evaluated. Several methods, based on T(1), T(2), or spectral shape, have previously been suggested to suppress or edit the macromolecule contributions. Here, a method is presented based on a series of saturation recovery scans and that allows for simultaneous recording of the macromolecular baseline and the fully relaxed metabolite spectrum. In comparison to an inversion recovery technique aimed at nulling signals from long-T(1) components, the saturation recovery method is less susceptible to T(1) differences inherent in signals from different metabolites or introduced by pathology. The saturation recovery method was used to quantitate the macromolecular baseline in white and/or gray matter locations of the human brain in 40 subjects. It was found that the content and composition of MR visible macromolecules depends on cerebral location, as well as the age of the investigated subject, while no gender dependence could be found.

Adult↗

Quantitation of localized (31)P magnetic resonance spectra based on the reciprocity principle.

There is a need for absolute quantitation methods in (31)P magnetic resonance spectroscopy, because none of the phosphorous-containing metabolites is necessarily constant in pathology. Here, a method for absolute quantitation of in vivo (31)P MR spectra that provides reproducible metabolite contents in institutional or standard units is described. It relies on the reciprocity principle, i.e., the proportionality between the B(1) field map and the map of reception strength for a coil with identical relative current distributions in receive and transmit mode. Cerebral tissue contents of (31)P metabolites were determined in a predominantly white matter-containing location in healthy subjects. The results are in good agreement with the literature and the interexamination coefficient of variance is better than that in most previous studies. A gender difference found for some of the (31)P metabolites may be explained by different voxel composition.

Adenosine Triphosphate↗

Variability of blood-brain ratios of phenylalanine in typical patients with phenylketonuria.

Blood-brain ratios (BBR) of phenylalanine (Phe) were determined by quantitative in vivo 1H magnetic resonance spectroscopy (1H-MRS) in 17 adult patients with early-treated phenylketonuria who were randomly selected from a sample of 75 adults. Measurements were performed in all patients during steady-state conditions. The BBR showed a unimodal distribution with a mean of 4.0 (range 3.3 to 4.5). Blood-brain ratios were comparable for subgroups of patients with genotypes classified as severe, moderate, or mild and for patients on different types of diets. Brain Phe concentrations showed a strong linear correlation with blood Phe values (r = 0.93, P < 0.001). There were no saturation effects for blood Phe values up to 1.8 mmol/L, and a local regression analysis did not confirm increasing BBR for increasing blood Phe values. The intellectual outcome (Wechsler Adult Intelligence Scale) was correlated with long-term dietary control (r = -0.65, P < 0.05), fluctuation of blood Phe values during treatment (r = -0.60, P < 0.05), and concurrent blood and brain Phe concentration. The severity of white matter changes visible on magnetic resonance images (MRI) was increased with high blood and brain Phe concentrations but failed to reach statistical significance. No correlation was found between BBR values, intelligence quotient, and MRI grade. Based on the assumption that BBR show intraindividual stability, the current data do not support the hypothesis that blood-brain barrier transport of Phe is a key explanatory factor for outcome variability in the vast majority of "typical" patients with phenylketonuria.

Adolescent↗

Muscle glycogen recovery after exercise measured by 13C-magnetic resonance spectroscopy in humans: effect of nutritional solutions.

The rate of glycogen resynthesis in human skeletal muscle after glycogen-depleting exercise is known to depend on carbohydrate intake and is reported to reach a plateau after an adequate amount of carbohydrate (CHO) consumption. Efforts to maximize the rate of glycogen storage by changing the type and form of CHO, as well as by adding proteins or lipids have yielded inconsistent results. The objective of this study was to assess whether isocaloric addition of proteins and arginine to a CHO diet in the first 4 h after an endurance exercise would increase the rate of glycogen synthesis. The CHO solution, given twice at a 2 h interval according to earlier optimized protocols, contained 1.7 g CHO/kg(body weieght) The effects of this solution were compared to those of an isocaloric solution containing 1.2 g CHO/kg(body weight) plus 0.5 g protein/kg(body weight) (including 5 g arginine). Glycogen was measured in quadriceps muscle in vivo with natural abundance 13C-magnetic resonance spectroscopy before exercise and twice after exercise, before and at the end of a 4-h period following the intake of one of the solutions. Eight subjects took part in a randomized cross-over trial separated by at least 1 week. Glycogen synthesis was found to be significantly increased with both regimes compared to a zero-caloric placebo diet, but no significant difference in glycogen resynthesis was found between the CHO-only diet and the one supplemented by proteins and arginine. It is estimated that significance would have been reached for an increase of 34%, while the effectively measured synthesis rates only differed by 5%.

Adult↗

Non-invasive observation of acetyl-group buffering by 1H-MR spectroscopy in exercising human muscle.

The observation of a previously unidentified peak in localized 1H magnetic resonance (MR) spectra of human muscle during and after a work load is reported. Basic NMR properties of this resonance, as well as physiologic circumstances of its observation, suggest that it is due to the acetyl group of acetylcarnitine. The relatively large pool of muscular carnitine acts as a buffering system stabilizing the ratio of acetylated to free coenzyme A. Free carnitine can be acetylated to a large extent whenever a mismatch occurs between the fluxes through pyruvate dehydrogenase and the TCA cycle. Results of initial applications of 1H MR spectroscopy in several muscles and under different exercise regimens are in agreement with earlier invasive measurements of acetylcarnitine. It is demonstrated that the detailed dynamics of acetyl group formation are now likely to be observable non-invasively in humans by localized 1H magnetic resonance spectroscopy on standard MR imaging systems, and that acetylcarnitine buffering as a function of exercise type, oxygenation states, diet and pathology could thus be studied repeatedly and in various muscle groups with much improved temporal resolution.

Acetylation↗

Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences.

A generally applicable method for almost complete suppression of signal artifacts on electrophysiological signals caused by B0-gradient switching (gradient noise) is presented. The method is demonstrated for electrocardiograms (ECGs) but can also be used for other electrophysiological signals. It takes advantage of the fact that under certain conditions, the effect of switching the B0-field gradient upon an electrophysiological signal can be modeled as a linear time-invariant system and fully characterized by pulse response functions. It is shown how the system's pulse response functions of the X, Y, and Z gradients can be determined and how gradient noise can be eliminated efficiently. The elimination of gradient noise by the proposed method causes in the current arrangement a constant delay of 128 msec, which is acceptable for patient monitoring and magnetic resonance sequence triggering.

Artifacts↗

Methods and reproducibility of cardiac/respiratory double-triggered (1)H-MR spectroscopy of the human heart.

Localized (1)H-MR spectroscopy is sensitive to motion and has mostly been applied to the brain. For the human heart, cardiac and respiratory motion lead to displacements on the order of the localized voxel and lead to substantial variations of voxel content, lineshape, water suppression, and signal phase and amplitude. Combined respiratory and cardiac double triggering can avoid these complications to a large extent. Three methods of double triggering are evaluated, with reproducibility established in nine subjects for a method based on respiratory modulation of the ECG amplitude and a visual feedback mechanism. Quantitated with respect to water, within-subject reproducibilities for this setup were 9% for trimethylammonium compounds, 10% for creatine/phosphocreatine, and 13% for lipids. ANOVA showed significant differences between subjects which may relate to natural variability between subjects or exact location within the heart. Unresolved issues for this technique are its susceptibility to precise placement of ECG electrodes and the reasons for failure in 20% of examination. With this technique it is possible to investigate open questions in cardiac pathophysiology, such as the creatine content in chronic heart disease. Variants of this triggering method may also improve cardiovascular MRI methods relying on data acquired in several heartbeats. Magn Reson Med 42:903-910, 1999.

Adult↗

Effect of exercise on the creatine resonances in 1H MR spectra of human skeletal muscle.

1H MR spectra of human muscles were recorded before, during, and after fatiguing exercise. In contrast to expectations, it was found that the spectral contributions of creatine/phosphocreatine (Cr/PCr) were subject to change as a function of exercise. In particular, the dipolar-coupled methylene protons of Cr/PCr were found to be reduced in intensity in proportion to the co-registered PCr levels. Recovery after exercise and behavior under ischemic conditions provide further evidence to suggest that the contributions of the CH2 protons of Cr/PCr to 1H MR spectra of human muscle in vivo reflect PCr rather than Cr levels. Variation of experimental parameters showed that this effect is not due to a trivial change in relaxation times. At present it can only be speculated about why the Cr resonances have reduced NMR visibility. If temporary binding to macromolecules should be involved, the free Cr concentration-important for equilibrium calculations of the creatine kinase reaction-might be different from what was previously assumed.

Adult↗

Observation of intramyocellular lipids by means of 1H magnetic resonance spectroscopy.

Magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) are being increasingly used for investigations of human muscle physiology. While MRI reveals the morphology of muscles in great detail (e.g. for the determination of muscle volumes), MRS provides information on the chemical composition of the tissue. Depending on the observed nucleus, MRS allows the monitoring of high-energy phosphates (31P MRS), glycogen (13C MRS), or intramyocellular lipids (1H MRS), to give only a few examples. The observation of intramyocellular lipids (IMCL) by means of 1H MRS is non-invasive and, therefore, can be repeated many times and with a high temporal resolution. MRS has the potential to replace the biopsy for the monitoring of IMCL levels; however, the biopsy still has the advantage that other methods such as those used in molecular biology can be applied to the sample. The present study describes variations in the IMCL levels (expressed in mmol/kg wet weight and ml/100 ml) in three different muscles before and after (0, 1, 2, and 5 d) marathon runs for a well-trained individual who followed two different recovery protocols varying mainly in the diet. It was shown that the repletion of IMCL levels is strongly dependent on the diet post exercise. The monitoring of IMCL levels by means of 1H MRS is extremely promising, but several methodological limitations and pitfalls need to be considered, and these are addressed in the present review.

Diet↗

Creatine supplementation--part II: in vivo magnetic resonance spectroscopy.

PURPOSE: Our purpose was to study effects of creatine (Cr) supplementation on muscle metabolites noninvasively by means of magnetic resonance spectroscopy (MRS) before and after supplementation with Cr or placebo. METHODS: 1H-MRS was used in a comprehensive, double-blind, cross-over study in 10 volunteers to measure Cr in m. tibialis anterior and m. rectus femoris at rest. PCr/ATP was observed in m. quadriceps femoris by 31P-MRS at rest and after exercise. RESULTS: A significant increase in total Cr was observed with Cr intake in m. tibialis anterior (+9.6 +/- 1.7%, P = 0.001) and in m. rectus femoris (+18.0 +/- 1.8%, P < 0.001). PCr/ATP showed a significant increase (+23.9 +/- 2.3%, P < 0.001) in m. quadriceps femoris at rest with Cr supplementation. Post-Cr supplementation recovery rates from exercise were significantly lower (k = 0.029 s(-1), P < 0.01) compared with postplacebo consumption (k = 0.034 s(-1)) and presupplementation (k = 0.037 s(-1)). However, higher levels of PCr/ATP at rest compensate for this reduction of the recovery rate after Cr supplementation. The increase of PCr/ATP determined by 31P-MRS correlates with the increase of Cr observed by 1H-MRS (r = 0.824, P < 0.001). CONCLUSION: Noninvasive observation of Cr and PCr after Cr supplementation shows an increase in a muscle specific manner. Higher preexercise levels of PCr/ATP at rest compensate for significantly slower recovery rates of PCr/ATP after Cr supplementation.

Adenosine Triphosphate↗

Neonatal body composition: dual-energy X-ray absorptiometry, magnetic resonance imaging, and three-dimensional chemical shift imaging versus chemical analysis in piglets.

An animal study to evaluate dual-energy x-ray absorptiometry (DXA) and magnetic resonance (MR) imaging and spectroscopy for measurement of neonatal body composition was performed. Twenty-three piglets with body weights ranging from 848 to 7550 g were used. After measuring total body water, animals were killed and body composition was assessed using DXA and MR (1.5 T; MR imaging, T1-weighted sagittal spin-echo sequence; MR spectroscopy, three-dimensional chemical shift imaging) as well as chemical carcass analysis (standard methods) after homogenization. Body composition by chemical analysis (percent of body weight, mean +/- SD) was as follows: body water, 75.3 +/- 3.9%; total protein, 13.9 +/- 8.8%; and total fat, 6.5 +/- 3.7%. Absolute content of fat and total ash was 7-674 and 35-237 g, respectively. Mean hydration of fat-free mass was 0.804 +/- 0.011 g/kg and decreased with increasing body weight (r2 = 0.419) independent of age. Using DXA, bone mineral content was highly correlated with calcium content (r2 = 0.992), and calcium per bone mineral content was 44.1 +/- 4.2%. DXA fat mass correlated with total fat (r2 = 0.961). Using MR, spectroscopy and chemical analysis were highly correlated with fat-to-water ratio (r2 = 0.984) and absolute fat content (r2 = 0.988). Total fat by MR imaging volumetry showed a lower correlation (r2 = 0.913) and overestimated total fat by a factor of 2.46. Conversion equations for DXA were developed (total fat = 1.31 x fat mass measured by DXA--68.8; calcium = 0.402 x bone mineral content + 1.7), which improved precision and accuracy of DXA measurements. In conclusion, both DXA and MR spectroscopy give accurate and precise estimates of neonatal body composition and may become valuable tools for the noninvasive assessment of neonatal growth and nutritional status.

Absorptiometry, Photon↗

Versatile frequency domain fitting using time domain models and prior knowledge.

An iterative nonlinear least-squares fitting algorithm in the frequency domain using time domain models for quantification of complex frequency domain MR spectra is presented. The algorithm allows incorporation of prior knowledge and has both the advantage of time-domain fitting with respect to handling the problem of missing data points and truncated data sets and of frequency-domain fitting with respect to multiple frequency-selective fitting. The described algorithm can handle, in addition to Lorentzian and Gaussian lineshapes, Voigt and nonanalytic lineshapes. The program allows the user the design of his own fitting strategy to optimize the probability of reaching the global least-squares minimum. The application of the fitting program is illustrated with examples from in vivo 1H-, 31P-, and 13C-MR spectroscopy.

Algorithms↗

Absolute metabolite quantification by in vivo NMR spectroscopy: IV. Multicentre trial on MRSI localisation tests.

The difference between the experimental and theoretical spatial response function (SRF) of a narrow tube with water is used for a localization test for magnetic resonance spectroscopic imaging (MRSI). From this difference a quantitative performance parameter is derived for the relative amount of signal within a limited region in the field of view. The total signal loss by the MRSI experiment and eddy currents is described by a parameter SL derived from the signal intensities of two echoes. Results of a European multi-centre trial show that this approach is suited for assessment of MRSI localization performance.

Animals↗

In vivo determination of intra-myocellular lipids in human muscle by means of localized 1H-MR-spectroscopy.

Intra-myocellular lipids (IMCL) are stored in droplets in the cytoplasm of muscle cells and are an energy storage form readily accessed during long-term exercise. 1H-MR spectroscopy methods are presented for noninvasive determination of IMCL in human muscle. This is based on (a) the separation of two resonances in the lipid-CH2-region, with the one assigned to IMCL being independent of muscle orientation relative to the magnetic field and (b) the fact that IMCL resonances scale along with signal amplitudes of metabolites in the muscle cell (e.g., creatine) when voxel size is increased, while lipid signals of bulk fat show a disproportionate growth. Inter-individual and intra-individual reproducibility studies indicate that the error of the method is about 6% and that IMCL levels differ significantly between identical muscles in different subjects, as well as intra-individually when measured at 1 week intervals. IMCL determinations in a single subject before and after strenuous exercise indicate that lipid stores recover with a t1/2 of about 1 day.

Adult↗

Quality assessment in in vivo NMR spectroscopy: V. Multicentre evaluation of prototype test objects and protocols for performance assessment in small bore MRS equipment.

This paper reports the results of multicentre studies aimed at designing, constructing, and evaluating prototype test objects for performance assessment in small-bore MRS systems, by utilizing the test protocols already proposed by the EEC COMAC-BME Concerted Action for clinical MRS equipment. Three classes of test objects were considered: (1) a multicompartment test object for 31P MRS measurements performed with slice-selective sequences; (2) a two-compartment test object for volume-selection 1H MRS; and (3) two-compartment test objects for assessing the performance of experimental systems using ISIS as volume localization sequence in 31P MRS. The results suggested the interest of adopting some of these prototypes for improving the comparison of spectroscopy data obtained from different sites, for providing useful means of quality assurance in experimental MRS, and facilitating the validation of new localization sequences.

Magnetic Resonance Spectroscopy↗

Spatially selective RF pulses and the effects of digitization on their performance.

Spectrometers make use of D/A converters to generate RF and gradient shapes. This paper examines by exact simulations the time and amplitude digitization effects, inherent to the use of D/A converters, on the performance of amplitude modulated (AM) frequency selective RF pulses. By making use of Fourier theory and the small tip angle approximation, an approximate model of these effects on the magnetization slice profiles is derived and verified for several pulse types by computer simulations. This approximate model will be used to derive requirements for D/A converters with respect to spatial localization. The dynamics of the spin system allows pulse width modulation (PWM) as an alternative to AM for pulse envelope encoding. The effects of PWM on the slice profile are examined and compared with conventional AM pulses. It is shown by simulation and measurement that adiabatic PWM pulses can be found. In contrast to AM modulated adiabatic pulses, adiabatic PWM pulses have side bands with the same slice quality as the main slice and might therefore be useful as multislice selective pulses.

Magnetic Resonance Spectroscopy↗