PubMed Health⌕ Search

Biomedical subjects

J Souchek

Publications and source records attributed to J Souchek.

30 records · Page 2Linked to original sources

Incidence of retinal detachment following Nd:YAG capsulotomy after cataract surgery.

In a retrospective study, we reviewed 218 consecutive Nd:YAG laser posterior capsulotomies performed at the Gimbel Eye Centre between June 1987 and November 1989 for the incidence of retinal detachment (RD) following treatment. Matched controls were found for 198 YAG cases. The median post-surgical follow-up for the YAG cases was 49.5 months; for the controls, 50.0 months. The median time between cataract extraction and YAG laser posterior capsulotomy was 24.8 months. The median follow-up after YAG was 24.2 months. Two of the 198 YAG cases (1.0%) and one of the 198 controls (0.5%) had RD. In the YAG cases, RD occurred 54.8 and 36.5 months after cataract surgery; in the control cases, 51.8 months after cataract surgery. Retinal detachment occurred at 15.0 and 17.0 months after YAG capsulotomy. These rates were lower than those reported in the literature. We feel that the surgical techniques of continuous circular capsulorhexis and in-the-bag IOL placement reduce the risk of RD following Nd:YAG posterior capsulotomy.

Aged↗

Determinants of survival and left ventricular performance after mitral valve replacement. Department of Veterans Affairs Cooperative Study on Valvular Heart Disease.

To determine how survival and clinical status were related to left ventricular (LV) size and systolic function after mitral valve replacement, 104 patients (48 mitral regurgitation [MR], 33 mitral stenosis [MS], and 23 MS/MR) with isolated mitral valve replacement were evaluated before and after surgery. Preoperative hemodynamic abnormalities by cardiac catheterization were improved 6 months after surgery in all three patient groups. The patients with MR exhibited reductions in LV end-diastolic volume index (EDVI) (117 +/- 51 to 89 +/- 27 ml/m2, p less than 0.001) and ejection fraction (EF) (0.56 +/- 0.15 to 0.45 +/- 0.13, p less than 0.001); however, the ratio of forward stroke volume to end-diastolic volume increased (0.32 +/- 0.21 to 0.45 +/- 0.17, p less than 0.001) because of the elimination of regurgitant volume. Survival analysis revealed that mortality was significantly higher in MS or MS/MR patients with postoperative EDVI more than 101 ml/m2 (p less than 0.001 and p less than 0.042, respectively) and in MR patients with postoperative EF less than or equal to 0.50 (p less than 0.031). Also, the majority of patients with MR or MS/MR and postoperative EDVI more than 101 ml/m2 and EF less than or equal to 0.50 were in New York Heart Association class III or IV. Multivariate logistic regression analysis in the patients with MR revealed that the strongest predictor of postoperative EF was preoperative EF (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography↗

The statistical analysis of graft patency data in a clinical trial of antiplatelet agents following coronary artery bypass grafting.

Because most coronary artery bypass patients receive more than one graft at surgery, it is most important to determine whether statistical analysis of graft patency should be performed on the premise that the multiple grafts within patients are dependent or independent experimental units. Veterans Administration Cooperative Study No. 207 was a multicenter clinical trial comparing four different antiplatelet regimens to placebo in the prevention of graft occlusion following coronary artery bypass grafting. Using the results from the 1-week postoperative angiograms from the Veterans Administration Cooperative Study No. 207, in which there were 3.2 distal anastomoses per patient, we have tested the hypothesis that grafts within patients tend to act dependently with respect to patency or occlusion by comparing the graft patency data to a binomial distribution (i.e., that distribution that would have been manifest if grafts were independent). Because the graft patency results in Study No. 207 significantly deviated from the binomial distribution (p = 0.0003), a more appropriate analysis for graft patency data was applied using a ratio estimate as applied to cluster sampling. The statistical methods used in 11 previous clinical trials of antithrombotic therapy after coronary artery bypass grafting were examined. Only one of the previous studies used such an analysis, and three additional reports attempted to correct for dependency of grafts within patients in their analyses using other statistical methods. In seven of the studies the investigators did not address the potential problem of a dependent relationship between multiple grafts within patients. We conclude that grafts within patients act as dependent experimental units and that the ratio estimate as applied to cluster sampling may be appropriately applied to these data.

Clinical Trials as Topic↗

Six month postoperative hemodynamics of the Hancock heterograft and the Björk-Shiley prosthesis: results of a Veterans Administration cooperative prospective randomized trial.

In a Veterans Administration Cooperative Study involving 13 medical centers, 575 patients undergoing single valve replacement were prospectively randomized to receive either the standard Björk-Shiley prosthesis or the Hancock porcine heterograft (with a modified orifice for sizes 23 and smaller). The hemodynamic data in the 268 patients who underwent cardiac catheterization an average of 6 months (range 3 to 12) postoperatively are reported. Statistical analyses were performed on valve sizes 23, 25 and 27 in the aortic position, and 29, 31 and 33 in the mitral position. A wide variation was observed in mean pressure gradient and calculated orifice area in both valve types within all sizes in both the aortic and the mitral positions. In the aortic position, the Björk-Shiley prosthesis tended to have a lower pressure gradient and larger calculated orifice area than the Hancock heterograft, but the differences in gradient between the two valve types were significant only in the larger-sized valves. The difference in calculated area between the two valve types was not significant within each valve size. In the mitral position, there were no differences in gradient and calculated orifice area between the two types of prostheses. The postoperative cardiac index, regurgitant volume, pulmonary artery systolic and mean pressures, left ventricular end-diastolic pressure, left ventricular ejection fraction and left ventricular end-diastolic volume index did not differ in patients receiving the Björk-Shiley prosthesis from values in patients receiving the Hancock heterograft. Hence, the overall hemodynamic performance of both types of valves is remarkably similar. The choice between these two prostheses should, therefore, be governed not by the hemodynamic performance, but by other factors such as valve durability, risk of anticoagulation and incidence of valve-related complications.

Aortic Valve↗

Comparison of outcome after valve replacement with a bioprosthesis versus a mechanical prosthesis: initial 5 year results of a randomized trial.

The Veterans Administration Cooperative Study on Valvular Heart Disease was organized to compare survival and incidence of valve-related complications between patients receiving a bioprosthesis (the Hancock porcine heterograft) and a mechanical prosthesis (the Björk-Shiley spherical disc valve). Five hundred seventy-five patients undergoing single aortic or mitral valve replacement were randomized at surgery to one of the two valve types. At an average follow-up of 5 years (range 3 to 8) there are no statistically significant differences in survival between patients with the two valve types in the aortic valve replacement group. There is a statistically nonsignificant trend toward improved survival in patients undergoing mitral valve replacement with a bioprosthesis compared with a mechanical prosthesis (5 year survival probability was 0.70 +/- 0.05 and 0.58 +/- 0.06, respectively). Fatal and nonfatal valve-related complications occurred significantly less frequently in patients with a bioprosthesis compared with a mechanical prosthesis for both mitral and aortic valve replacement. Five year complication-free probability was 0.67 +/- 0.05 and 0.45 +/- 0.06, respectively, for patients with mitral valve replacement and 0.63 +/- 0.04 and 0.53 +/- 0.04, respectively, for those with aortic valve replacement. The difference in overall complication rates was largely due to the increased number of clinically significant but nonfatal bleeding episodes in patients receiving a mechanical prosthesis. Adjustment for differences in baseline characteristics between patients receiving a mitral mechanical prosthesis and a mitral bioprosthesis reduced the statistical significance of the difference in both mortality and complications.

Aortic Valve↗

Clinical, hemodynamic, and angiographic predictors of operative mortality in patients undergoing single valve replacement. Veterans Administration Cooperative Study on Valvular Heart Disease.

Preoperative characteristics of 964 patients in the Veterans Administration Cooperative Study on Valvular Heart Disease undergoing single valve replacement were examined to determine predictors of operative mortality. The operative mortality rate was 8.3% in 661 patients having isolated aortic valve disease and 7.5% in 239 patients having isolated mitral valve disease, but 12.5% in 64 patients with multivalve disease undergoing single valve replacement. For the aortic valve replacement subgroup, three-vessel coronary artery disease, left ventricular systolic pressure, prior cardiac operation, body surface area, and cardiac index were related to operative mortality. In the mitral valve replacement group, there was a strong association of operative mortality with advanced age, exertional dizziness, reduced cardiac index, left ventricular contraction grade, ST segment depression on the resting electrocardiogram, and pleural effusion. The risk of operative death for an individual patient undergoing aortic or mitral valve replacement may be estimated with the use of independent risk factors.

Adult↗

Death in aftercare.

Explore the source record for details and available documents.

Adult↗

Rates of health services utilization and survival in patients with heart failure in the Department of Veterans Affairs medical care system.

The objective of this study was to describe patterns of hospital and clinic use and survival for a large nationwide cohort of patients with heart failure. A retrospective cohort study of patients treated in the Veterans Affairs medical care system was conducted using linked administrative databases as data sources. In 1996, the average heart failure cohort member had 1-2 hospitalizations, 14 inpatient days, 6-7 visits with the primary physician, 15 other visits for consultations or tests, and 1-2 urgent care visits per 12 months. The overall risk-adjusted 5-year survival rate was 36%. Hospital use rates in the cohort fell dramatically between 1992 and 1996. One-year survival rates increased slightly over the period. Patients with heart failure are heavy users of services and have a very poor prognosis. Utilization and outcome data indicate the need for major efforts to assure quality of care and to devise innovative ways of delivering comprehensive services.

Adult↗