PubMed Health⌕ Search

Biomedical subjects

J Star-Lack

Publications and source records attributed to J Star-Lack.

7 recordsLinked to original sources

Clinical application of BASING and spectral/spatial water and lipid suppression pulses for prostate cancer staging and localization by in vivo 3D 1H magnetic resonance spectroscopic imaging.

In previous in situ point-resolved spectroscopy (PRESS) three-dimensional (3D) 1H magnetic resonance (MR) spectroscopic imaging studies, it has been demonstrated that the ratio of prostatic metabolites can noninvasively discriminate prostate cancer from surrounding normal tissue. However, in these studies, conventional chemical shift selective suppression (CHESS) and short-time inversion recovery (STIR) techniques often resulted in inadequate water and lipid suppression. To improve suppression and spatial coverage, the newly developed T1 insensitive dual band selective inversion with gradient dephasing (BASING) Bandstop Filter and dual phase-compensating spectral/spatial spin-echo pulses have been implemented in a clinical setting. In phantom studies, no change in metabolic profiles was observed with application of either BASING or spectral/spatial pulses. In a study of 17 prostate cancer patients, the use of either BASING or spectral/spatial pulses allowed for suppression of water (BASING 99.80 +/- 0.14% and spectral/spatial 99.73 +/- 0.47%) and lipid (BASING 98.56 +/- 1.03% and spectral/spatial 98.44 +/- 1.90%) without a significant difference in the prostatic metabolite ratios. Spectral/spatial suppression has the added advantage of reducing the chemical shift dependence of the PRESS volume, but optimal performance requires high-speed gradients with negligible eddy current effects. BASING suppression is less reliant on accurate pulse and gradient timings and can be implemented easily with no loss in performance on clinical MR scanners with conventional gradients.

Adenocarcinoma↗

High spatial resolution 1H-MRSI and segmented MRI of cortical gray matter and subcortical white matter in three regions of the human brain.

High-resolution MR imaging and spectroscopic imaging were used to study differences in proton spectra between cortical gray matter and subcortical white matter in 23 normal volunteers using a 1.5 T scanner and surface coil receivers. A point-resolved spectroscopy (PRESS) volume with an 8 x 8 x 8 phase-encoding matrix was used to acquire over 1900 0.09-0.2 cc spectral voxels. The high-resolution (0.7 x 0.7 x 0.8 mm3 or 0.8 x 0.8 x 1 mm3) images were corrected for the surface coil reception profile and segmented into cerebrospinal fluid (CSF) and gray and white matter to correlate with the spectra. The data showed that N-acetyl aspartate (NAA) and creatine (Cr) were higher in the gray matter than in the white matter (NAA(g/w) = 1.4+/-0.36, Cr(g/w) = 1.4+/-0.41). Choline was significantly lower in the gray matter of the occipital lobe than in the white matter (0.73+/-0.19), but not significantly different in the other regions. NAA/Cho was found to be significantly higher in the occipital lobe than in the left frontal or vertex regions.

Adult↗

Reduced spatial side lobes in chemical-shift imaging.

Density-weighted k-space sampling with spiral trajectories is used to reduce spatial side lobes in chemical-shift imaging (CSI). In this method, more time is spent collecting data at the center of k space and less time at the edges of k space in order to make the sampling density proportional to a given apodization function, subject to constraints imposed by gradient performance and Nyquist sampling. The efficient k-space coverage of spiral-based trajectories enables good control over the sampling density within practical in vivo scan times. The density-weighted acquisition is compared to a conventional, nonweighted spiral sampling without the application of a window function. For a fixed voxel size and imaging time, the noise variance is observed to be the same for both cases, while spatial side lobes are greatly reduced with the variable-density sampling. This method is demonstrated on a normal volunteer by imaging of brain metabolites at 1.5 T with both single slice CSI and volumetric CSI. Magn Reson Med 42:314-323, 1999.

Brain↗

In vivo lactate editing with simultaneous detection of choline, creatine, NAA, and lipid singlets at 1.5 T using PRESS excitation with applications to the study of brain and head and neck tumors.

Two T2-independent J-difference lactate editing schemes for the PRESS magnetic resonance spectroscopy localization sequence are introduced. The techniques, which allow for simultaneous acquisition of the lactate doublet (1.3 ppm) and edited singlets upfield of and including choline (3.2 ppm), exploit the dependence of the in-phase intensity of the methyl doublet upon the time interval separating two inversion (BASING) pulses applied to its coupling partner after initial excitation. Editing method 1, which allows for echo times TE = n/J (n = 1, 2, 3, . . . . ), alters the BASING carrier frequency for each of two cycles so that, for one cycle, the quartet is inverted, whereas, for the other cycle, the quartet is unaffected. Method 2, which also provides water suppression, allows for editing for TE > 1/J by alternating, between cycles, the time interval separating the inversion pulses. Experimental results were obtained at 1.5 T using a Shinnar Le-Roux-designed maximum phase inversion pulse with a filter transition bandwidth of 55 Hz. Spectra were acquired from phantoms and in vivo from the human brain and neck. In a neck muscle study, the lipid suppression factor, achieved partly through the use of a novel phase regularization algorithm, was measured to be over 10(3). Spectra acquired from a primary brain and a metastatic neck tumor demonstrated the presence of lactate and choline signals consistent with abnormal spectral patterns. The advantages and limitations of the methods are analyzed theoretically and experimentally, and significance of the results is discussed.

Aspartic Acid↗

High spatial resolution and speed in MRSI.

The in vivo applications of magnetic resonance spectroscopic imaging (MRSI) have expanded significantly over the past 10 years and have reached the point where clinical trials are underway for a number of different diseases. One of the limiting factors in the widespread use of this technology has been the lack of widely available tools for obtaining data which are localized to sufficiently small tissue volumes to make an impact upon diagnosis and treatment planning. This is especially difficult within the timeframe of a clinical MR examination, which requires that both anatomic and metabolic data are acquired and processed. Recent advances in the hardware and software associated with clinical scanners have provided the potential for improvements in the spatial and time resolution of imaging and spectral data. The two areas which hold the most promise in terms of MRSI data are the use of phased array coils and the implementation of echo planar k-space sampling techniques. These could have immediate impact for 1H MRSI and may prove valuable for future applications of 31P MRSI.

Brain Neoplasms↗

Improved water and lipid suppression for 3D PRESS CSI using RF band selective inversion with gradient dephasing (BASING).

A T1 insensitive solvent suppression technique-band selective inversion with gradient dephasing (BASING)-was developed to suppress water and lipids for 1H magnetic resonance spectroscopy (MRS). BASING, which consists of a frequency selective RF inversion pulse surrounded by spoiler gradient pulses of opposite signs, was used to dephase stopband resonances and minimally impact passband metabolites. Passband phase linearity was achieved with a dual BASING scheme. Using the Shinnar-Le Roux algorithm, a highpass filter was designed to suppress water and rephase the lactate methyl doublet independently of TE, and water/lipid bandstop filters were designed for the brain and prostate. Phantom and in vivo experimental 3D PRESS CSI data were acquired at 1.5 T to compare BASING with CHESS and STIR suppression. With BASING, the measured suppression factor was over 100 times higher than with CHESS or STIR causing baseline distortions to be removed. It was shown that BASING can be incorporated into a variety of sequences to offer improved suppression in the presence of B1 and T1 inhomogeneites.

Brain Chemistry↗

Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/spatial spin-echo pulses.

Dual phase-compensating spectral/spatial echo-planar (EP) spin-echo (SE) pulses were incorporated into the point resolved spectroscopy (PRESS) excitation sequence to improve water and lipid suppression for 1H chemical shift imaging (CSI) and to decrease the dependence of the PRESS box location upon chemical shift. The asymmetric EPSE pulses (either minimum or maximum phase in the chemical shift domain) were substituted for the two PRESS SE pulses to yield zero phase spectra. Three different pulses were designed and tested at 1.5 T. Pulse 1, targeted for brain CSI (TE > 85 msec), passed choline to lipid resonances, suppressed water, and rephased the methyl lactate doublet independently of TE. Pulse 2, targeted for general purpose shorter TE PRESS, possessed both high chemical shift and spatial domain bandwidths. Pulse 3, designed for prostate CSI, passed choline to citrate resonances while suppressing lipids and water. The three pulses possessed spatial bandwidths ranging between 3.3 and 5.0 kHz, more than three times higher than that offered by one-dimensional SE pulses of equivalent maximum B1 amplitude. Phantom and in vivo experimental results demonstrated that, for EPSE pulses 1 and 2, suppression factors higher than 10(4) were achieved. The increased spatial bandwidths resulted in less contamination by signals from outside the designated PRESS excited region and a significant improvement in the uniformity of metabolite intensities for voxels located near edges of the PRESS box.

Aged↗