Publications and source records attributed to J Stefan Petersson.

5 recordsLinked to original sources

Molecular imaging with endogenous substances.

Dynamic nuclear polarization has enabled hyperpolarization of nuclei such as 13C and 15N in endogenous substances. The resulting high nuclear polarization makes it possible to perform subsecond 13C MRI. By using the dynamic nuclear polarization hyperpolarization technique, 10% polarization was obtained in an aqueous solution of 100 mM 13C-labeled urea, ready for injection. The in vivo T1 relaxation time of 13C in the urea solution was determined to 20 +/- 2 s. Due to the long relaxation time, it is possible to use the hyperpolarized substance for medical imaging. A series of high-resolution ( approximately 1-mm) magnetic resonance images were acquired, each with a scan time of 240 ms, 0-5 s after an i.v. injection of the hyperpolarized aqueous [13C]urea solution in a rat. The results show that it is possible to perform 13C angiography with a signal-to-noise ratio of approximately 275 in approximately 0.25 s. Perfusion studies with endogenous substances may allow higher spatial and/or temporal resolution than is possible with current proton imaging techniques.

Animals↗

Hyperpolarized 13C MR angiography using trueFISP.

A (13)C-enriched water-soluble compound (bis-1,1-(hydroxymethyl)-1-(13)C-cyclopropane-D(8)), with a (13)C-concentration of approximately 200 mM, was hyperpolarized to approximately 15% using dynamic nuclear polarization, and then used as a contrast medium (CM) for contrast-enhanced magnetic resonance angiography (CE-MRA). The long relaxation times (in vitro: T(1) approximately 82 s, T(2) approximately 18 s; in vivo: T(1) approximately 38 s, T(2) approximately 1.3 s) are ideal for steady-state free precession (SSFP) imaging with a true fast imaging and steady precession (trueFISP) pulse sequence. It was shown both theoretically and experimentally that the optimal flip angle was 180 degrees. CE-MRA was performed in four anesthetized live rats after intravenous injection of 3 ml CM. The angiograms covered the thoracic/abdominal region in two of the animals, and the head-neck region in the other two. Fifteen consecutive images were acquired in each experiment, with a flip-back pulse at the end of each image acquisition. In the angiograms, the vena cava (SNR approximately 240), aorta, renal arteries, carotid arteries (SNR approximately 75), jugular veins, and several other vessels were visible. The SNR in the cardiac region was 500. Magnetization was preserved from one image acquisition to the next using the flip-back technique (SNR(cardiac) approximately 10 in the 15th image).

Animals↗

Quantitative measurement of regional lung ventilation using 3He MRI.

A new strategy for a quantitative measurement of regional pulmonary ventilation using hyperpolarized helium-3 (3He) MRI has been developed. The method employs the build-up of the signal intensity after a variable number of (3)He breaths. A mathematical model of the signal dynamics is presented, from which the local ventilation, defined as the fraction of gas exchanged per breath within a given volume, is calculated. The model was used to create ventilation maps of coronal slices of guinea pig lungs. Ventilation values very close to 1 were found in the trachea and the major airways. In the lung parenchyma, regions adjacent to the hilum showed values of 0.6-0.8, whereas 0.2-0.4 was measured in peripheral regions. Monte Carlo simulations were used to investigate the accuracy of the method and its limitations. The simulations revealed that, at presently attainable signal-to-noise ratios, the ventilation parameter can be determined with a relative uncertainty of <5% over a wide range of values.

Animals↗

13C-angiography.

Explore the source record for details and available documents.

Animals↗