PubMed HealthSearch

Biomedical subjects

J Sturis

Publications and source records attributed to J Sturis.

6 recordsLinked to original sources

Abnormalities in the ultradian oscillations of insulin secretion and glucose levels in type 2 (non-insulin-dependent) diabetic patients.

To investigate the temporal organization of insulin secretion and glucose concentration during fasting in Type 2 (non-insulin-dependent) diabetes mellitus, we studied seven patients with Type 2 diabetes, eight obese non-diabetic control subjects and eight normal weight non-diabetic subjects. Blood sampling for glucose, insulin and C-peptide was performed at 15-min intervals during a 24-h period of fasting for the diabetic and the obese control subjects and during an 8-h fasting period for the normal subjects. Insulin secretion rates were calculated from the peripheral C-peptide concentration profiles. Ultradian oscillations of glucose levels and insulin secretion rates were evident during fasting in all subjects. An additional study with blood sampling at 2-min intervals for 8 h further indicated that this ultradian periodicity is expressed independently of rapid 10-15 min insulin oscillations. There were no differences between diabetic and non-diabetic subjects in the frequency of the ultradian oscillations of insulin secretion (which averaged 12-15 oscillations per 24 h) and in the rate of concomitancy of oscillations of insulin secretion with oscillations in glucose levels, which averaged 63-65%. The relative amplitudes of both the insulin and glucose oscillations were also similar in diabetic and nondiabetic subjects. The major abnormality in patients with Type 2 diabetes was evidenced by spectral analysis, and confirmed by calculations of the distributions of inter-pulse intervals. It consisted of a slowing of the glucose oscillations, without a similar slowing of the oscillations in insulin secretion.(ABSTRACT TRUNCATED AT 250 WORDS)

Activity Cycles

Insulin secretory profiles and C-peptide clearance kinetics at 6 months and 2 years after kidney-pancreas transplantation.

Glucose, insulin secretion, and insulin secretory pulses were measured by deconvolution of peripheral C-peptide concentrations in 10 IDDM recipients of a combined kidney-pancreas allograft 6 mo post-transplantation and were compared with 10 matched nondiabetic control subjects. Seven of the 10 recipients were restudied 2 yr post-transplantation. To control for immunosuppressive therapy, 6 patients with a kidney allograft also were studied. Pancreatic insulin secretion rates were evaluated over a 24-h period with three mixed meals. Six months post-transplantation, fasting (5.3 +/- 0.1 vs. 5.3 +/- 0.1 mM), average 24-h (6.0 +/- 0.1 vs. 5.7 +/- 0.1 mM), and meal-related (6.1 +/- 0.3 vs. 5.8 +/- 0.2 mM) plasma glucose levels were not different in control subjects and recipients, respectively. Total 24-h insulin secretion rates were similar between the two groups (150 +/- 15 vs. 182 +/- 24 nmol.m-2.24 h-1). However, post-transplantation, the relationship between basal and meal-stimulated insulin secretion was altered with increased basal insulin secretion (52.2 +/- 6.4 vs. 97.4 +/- 12.5 pmol.m-2.min-1, P less than 0.004) and reduced meal-related secretion. The proportion of total 24-h insulin secretion comprised by basal secretion was 44 +/- 4% in the control subjects vs. 73 +/- 5% in recipients. The number of ultradian oscillations of insulin secretion identified in each 24-h period by pulse analysis was similar in control subjects and recipients (11.9 +/- 0.9 vs. 10.4 +/- 0.5 oscillations/24 hr).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Estimation of insulin secretion rates from C-peptide levels. Comparison of individual and standard kinetic parameters for C-peptide clearance.

Insulin secretion rates can be accurately estimated from plasma C-peptide levels with a two-compartment model for C-peptide distribution and degradation. In previous studies, the kinetic parameters of C-peptide clearance were derived in each subject from the decay curve observed after bolus intravenous injection of biosynthetic human C-peptide. To determine whether standard parameters for C-peptide clearance could be defined and used to calculate insulin secretion without obtaining a decay curve in each subject, we analyzed 200 decay curves of biosynthetic human C-peptide obtained in normal, obese, and non-insulin-dependent diabetes mellitus subjects studied in our laboratory. This analysis showed that the volume of distribution and kinetic parameters of C-peptide distribution and metabolism vary by less than 30% in a population highly heterogeneous in terms of age, sex, degree of obesity, and degree of glucose tolerance. The volume of distribution correlated with the degree of obesity as quantified by body surface area (BSA). This dependence of C-peptide distribution volume on BSA was more marked in men than in women. The long half-life was slightly longer in elderly subjects than in younger adults. When effects of BSA, sex, and age were taken into account, the parameters of C-peptide kinetics were very similar in normal, obese, and diabetic subjects. Based on these findings, a simple procedure to derive standard parameters for C-peptide clearance taking into account degree of obesity, sex, and age was defined. These standard parameters resulted in estimations of mean insulin secretion rates, which differed in each subject by only 10-12% from those obtained with individual parameters. The approach of using standard rather than individual parameters did not systematically underestimate or overestimate insulin secretion so that group values for the fasting secretion rate, the mean 24-h secretion rate, and the number and the amplitude of secretory pulses obtained with standard parameters differed by only 1-2% from the values obtained with individual parameters. Furthermore, the accuracy of measurements based on standard parameters was not different from that associated with replicate determinations of the parameters of C-peptide clearance in the same subject. We conclude that it is possible to estimate insulin secretion rates from plasma C-peptide levels with standard parameters for C-peptide clearance rather than individually derived parameters without significant loss of accuracy.

Adult

Hypoglycemic thresholds for cognitive dysfunction in IDDM.

Fourteen poorly controlled insulin-dependent diabetes mellitus (IDDM) patients (HbA1c 11 +/- 0.5%) with a mean +/- SE duration of disease of 15 +/- 2 yr were studied to evaluate the hypoglycemic threshold for cognitive dysfunction under insulin-induced hypoglycemia. The P300 event-related potential, a measure of cognitive function, and reaction time (RT) in response to visual stimuli under euglycemic conditions and at plasma glucose concentrations of 3.5 and 2.5 mM (63 and 45 mg/dl, respectively) during a constant insulin infusion were recorded. Baseline P300 latency was similar to that of a nondiabetic control group, but baseline RT was greater in the IDDM group. There was no increase in P300 latency or RT under euglycemic clamp conditions or at a plasma glucose level of 3.5 mM (63 mg/dl). However, when plasma glucose was lowered to 2.5 mM (45 mg/dl), there was an increase in P300 latency and a prolongation of RT. As plasma glucose returned to baseline, P300 latency and RT remained prolonged. After administration of intravenous glucose and a meal, P300 latency and RT returned to baseline. P140, an event-related potential reflecting sensory processes, was not altered. Because P300 latency changes paralleled RT changes, hypoglycemia appears to slow decision-making processes in IDDM. This study revealed that 1) baseline P300 latency is not elevated in poorly controlled IDDM patients, suggesting no cumulative cognitive dysfunction.

Blood Glucose

Computer model for mechanisms underlying ultradian oscillations of insulin and glucose.

Oscillations in human insulin secretion have been observed in two distinct period ranges, 10-15 min (i.e. rapid) and 100-150 min (i.e., ultradian). The cause of the ultradian oscillations remains to be elucidated. To determine whether the oscillations could result from the feedback loops between insulin and glucose, a parsimonious mathematical model including the major mechanisms involved in glucose regulation was developed. This model comprises two major negative feedback loops describing the effects of insulin on glucose utilization and glucose production, respectively, and both loops include the stimulatory effect of glucose on insulin secretion. Model formulations and parameters are representative of results from published clinical investigations. The occurrence of sustained insulin and glucose oscillations was found to be dependent on two essential features: 1) a time delay of 30-45 min for the effect of insulin on glucose production and 2) a sluggish effect of insulin on glucose utilization, because insulin acts from a compartment remote from plasma. When these characteristics were incorporated in the model, numerical simulations mimicked all experimental findings so far observed for these ultradian oscillations, including 1) self-sustained oscillations during constant glucose infusion at various rates; 2) damped oscillations after meal or oral glucose ingestion; 3) increased amplitude of oscillation after increased stimulation of insulin secretion, without change in frequency; and 4) slight advance of the glucose oscillation compared with the insulin oscillation.(ABSTRACT TRUNCATED AT 250 WORDS)

Activity Cycles

Entrainment of pulsatile insulin secretion by oscillatory glucose infusion.

Ultradian "oscillations" or "pulses" of insulin secretion with periods around 120 min occur in man. It is not known whether glucose plays an active role in generating these oscillations, or if an intrapancreatic pacemaker generates oscillations in insulin secretion that entrain glucose passively. To determine if the frequency of pulses of insulin secretion could be modified by oscillatory glucose infusion, seven normal men were studied on three separate occasions. The first study involved a constant glucose infusion administered at a rate of 6 mg/kg per min for 28 h. During the two subsequent studies, the subjects received an oscillatory glucose infusion for 28 h with the same mean rate, an amplitude of 33% above and below the mean infusion rate, a sinusoidal waveshape and a period either 20% longer ("slow oscillatory infusion") or 20% shorter ("rapid oscillatory infusion") than the periodicity observed during constant glucose infusion. Samples for insulin, C-peptide, and glucose were drawn at 10-min intervals during the last 24 h of each study. Insulin secretion rates were calculated by deconvolution of C-peptide levels. During constant glucose infusion, the respective periods of oscillation of glucose and insulin secretion averaged 126 +/- 5 min and 118 +/- 3 min (mean +/- SEM). During the slow oscillatory infusion, the period of infusion was 155 +/- 7 min and the periods of insulin secretion and glucose were, respectively, 155 +/- 7 min and 150 +/- 5 min. During rapid oscillatory infusion, the period of infusion was 103 +/- 5 min and the period of both insulin secretion and glucose was 105 +/- 5 min. Thus the periodicity of both insulin secretion and plasma glucose changed in parallel with the exogenous periodicity, indicating complete entrainment of the secretory oscillations. These results suggest that the ultradian oscillations of insulin secretion are caused by the feedback loop linking glucose and insulin.

Adult