PubMed Health⌕ Search

Biomedical subjects

J T Cope

Publications and source records attributed to J T Cope.

28 records · Page 2Linked to original sources

Euro-Collins solution exacerbates lung injury in the setting of high-flow reperfusion.

Single-lung transplantation has been abandoned for the treatment of pulmonary hypertension by many centers because of overperfusion of the graft following implantation. Euro-Collins solution is currently used for lung preservation despite the vasoconstrictive effect of this intracellular-type solution. We hypothesized that high-flow reperfusion, alone or in combination with Euro-Collins-induced vasoconstriction, may cause lung dysfunction. Twenty-eight New Zealand White rabbit lungs were harvested and studied in an isolated, blood-perfused model of lung function after 4 hours of cold ischemia. Control lungs were preserved with 50 ml/kg cold saline solution flush and reperfused at either normal flow (60 ml/min) or high flow (120 ml/min). Experimental lungs were preserved with 50 ml/kg cold Euro-Collins solution and reperfused at normal or high flow rates. The arteriovenous oxygen gradient at the end of the 30-minute reperfusion period was significantly lower in the high-flow versus the low-flow experimental group (31.1 +/- 4.2 vs 130.6 +/- 41.6 mm Hg, p < 0.05). The pulmonary vascular resistance was increased in the high-flow groups and the experimental groups, with a statistically significant difference between low-flow experimental and control groups (64374.4 +/- 5722.6 vs 37041.5 +/- 2110.9 dynes x sec x cm(-5), p < 0.001). The percentage decrease in dynamic airway compliance in the high-flow experimental group was markedly different from that in the high-flow control group (-51% +/- 13.3% vs -10.15% +/- 3.4%, p < 0.05). Similarly, the wet/dry ratio of the lungs in the high-flow experimental group (13.92 +/- 2.32) was significantly greater than that in the low-flow experimental group (6.27 +/- 0.19, p < 0.01) and than that in the high-flow control group (5.88 +/- 0.23, p < 0.001). These data demonstrate that high-flow reperfusion and preservation with Euro-Collins solution are deleterious to lung function, both individually and in combination, in an ex vivo rabbit lung model. Lung preservation with Euro-Collins solution may not be optimal when high-flow reperfusion is anticipated, as in the setting of unilateral lung transplantation for pulmonary hypertension.

Animals↗

Is clamp and sew still viable for thoracic aortic resection?

OBJECTIVE: The authors reviewed the morbidity and mortality of surgical resection of the descending thoracic and thoracoabdominal aorta using the clamp-and-sew technique. BACKGROUND: Paraplegia remains a devastating complication after thoracoabdominal aortic resection, despite many strategies for spinal cord protection. Because of its simplicity, clamp and sew has been the preferred technique at the University of Virginia for the thoracoabdominal aortic resection when proximal control is possible. METHODS: Between 1987 and 1994, the authors reviewed 91 consecutive patients who underwent thoracic aortic resection using clamp-and-sew techniques without any additional adjuncts for spinal cord protection. RESULTS: The average age of patients was 60.8 years; 57.1% were male. No intraoperative deaths occurred. In-hospital mortality was 13% (12/91), with an overall incidence of postoperative spinal cord injury manifested as paraparesis or paraplegia of 9.9% (9/91). Eighty-nine percent (81/91) of all repairs were completed with aortic clamp times of 40 minutes or less, and nearly six out of ten were completed in 30 minutes or less (53/91). Cross-clamp times were not significantly different between those patients who sustained neurologic injury and those who had no deficits. CONCLUSIONS: The authors conclude that clamp and sew is still a viable technique for thoracoabdominal aortic resection. Nearly all resections can be completed within 40 minutes of aortic occlusion. However, the "safe" duration of thoracic aortic occlusion remains unknown, and spinal cord injury can occur even with short clamp times. Reproducible, safe, and technically simple means of spinal cord protection must be developed.

Adolescent↗

Impaired bronchial healing after lung donation from non-heart-beating donors.

BACKGROUND: Bronchial viability after lung transplantation remains a concern. Modern preservation methods, surgical technique, and limited cold ischemic periods have decreased the frequency of bronchial complications. However, lungs procured from non-heart-beating donors are subjected to a mandatory period of warm ischemia. We investigated bronchial healing in a porcine survival model of left lung transplantation using organ procurement from non-heart-beating donors after a 60-minute period of warm ischemia. METHODS: Fourteen adult domestic swine underwent left lung transplantation. All lungs were preserved with cold Euro-Collins flush and stored inflated at 4 degrees C. Control lungs (n = 5) were flushed, harvested, and stored for 2 hours before implantation. Experimental lungs (n = 9) were procured from non-heart-beating donors. These lungs were subjected to 60 minutes of warm ischemia before flush and harvest, followed by 2 hours of cold storage before implantation. After 21 days of immunosuppression with prednisone, azathioprine, and cyclosporine, pulmonary function was assessed. Bronchial viability was evaluated with bronchoscopy and, at autopsy, followed by histologic analysis. RESULTS: Implantation time did not differ significantly between the control group and the experimental group (59.6 +/- 2.1 versus 64.4 +/- 2.9 minutes, p = 0.24). Control swine exhibited no evidence of ischemic injury to the donor bronchus. In contrast, six of nine lungs procured from non-heart-beating donors showed evidence of ischemic bronchial injury (p = 0.031 versus control). Findings ranged from hypovascular edematous mucosa to necrosis and sloughing of the mucosa throughout the entire donor bronchial tree. The remaining three non-heart-beating donor lungs exhibited normal lung function and bronchial healing. CONCLUSIONS: We conclude that 60 minutes of warm ischemia for lungs procured from non-heart-beating donors results in impaired bronchial viability with current preservation techniques. Thirty minutes of warm ischemia may be the acceptable limit for lung procurement from non-heart-beating organ donors.

Animals↗

Pulmonary function after non-heart-beating lung donation in a survival model.

BACKGROUND: Lung procurement from recently deceased cadavers has been suggested to enlarge the limited donor pool. We hypothesized that lungs harvested from non-heart-beating donors (NHBD) would function as well as those harvested from heart-beating donors. METHODS: Sixteen adult swine underwent left lung allotransplantation. Controls received lungs procured from heart-beating donors, NHBD pigs received lungs immediately harvested from donors after death from asphyxiation, and NHBD-15 and NHBD-30 pigs received lungs harvested after 15 and 30 minutes after asphyxiation. RESULTS: After 1 week of survival, mean dynamic airway compliance (mL/cm H2O +/- standard error of the mean) was 16.3 +/- 0.7 in controls, and 17.3 +/- 1.0, 16.4 +/- 6.0, and 7.3 +/- 1.6 in the NHBD, NHBD-15, and NHBD-30 groups, respectively (p = 0.02, NHBD-30 versus others combined). No significant differences were noted in the pulmonary venous partial pressure of oxygen or pulmonary vascular hemodynamics compared with controls. CONCLUSIONS: The decrease in airway compliance noted in the NHBD-30 group may reflect an exacerbation of reperfusion injury caused by 30 minutes of warm ischemia during organ retrieval. We conclude that posttransplantation lung function using an NHBD with up to 15 minutes of warm ischemia is equivalent to lung function after heart-beating harvest.

Animals↗

A simple technique for retrograde cerebral perfusion during circulatory arrest.

We describe a simple and safe technique for achieving retrograde cerebral perfusion via a small coronary sinus type catheter placed in the superior vena cava. This method is especially useful when the need for circulatory arrest is first recognized intraoperatively and a single two-stage venous cannula has already been placed for cardiopulmonary bypass. The advantages of this technique over other currently employed methods for retrograde cerebral perfusion are discussed.

Brain↗