PubMed Health⌕ Search

Biomedical subjects

J T Dennerlein

Publications and source records attributed to J T Dennerlein.

7 recordsLinked to original sources

Ergonomics and human factors in endoscopic surgery: a comparison of manual vs telerobotic simulation systems.

BACKGROUND: Minimally invasive surgical techniques expose surgeons to a variety of occupational hazards that may promote musculoskeletal disorders. Telerobotic systems for minimally invasive surgery may help to reduce these stressors. The objective of this study was to compare manual and telerobotic endoscopic surgery in terms of postural and mental stress. METHODS: Thirteen participants with no experience as primary surgeons in endoscopic surgery performed a set of simulated surgical tasks using two different techniques--a telerobotic master--slave system and a manual endoscopic surgery system. The tasks consisted of passing a soft spherical object through a series of parallel rings, suturing along a line 5-cm long, running a 32-in ribbon, and cannulation. The Job Strain Index (JSI) and Rapid Upper Limb Assessment (RULA) were used to quantify upper extremity exposure to postural and force risk factors. Task duration was quantified in seconds. A questionnaire provided measures of the participants' intuitiveness and mental stress. RESULTS: The JSI and RULA scores for all four tasks were significantly lower for the telerobotic technique than for the manual one. Task duration was significantly longer for telerobotic than for manual tasks. Participants reported that the telerobotic technique was as intuitive as, and no more stressful than, the manual technique. CONCLUSIONS: Given identical tasks, the time to completion is longer using the telerobotic technique than its manual counterpart. For the given simulated tasks in the laboratory setting, the better scores for the upper extremity postural analysis indicate that telerobotic surgery provides a more comfortable environment for the surgeon without any additional mental stress.

Arm↗

Predictors of whole-body vibration levels among urban taxi drivers.

To identify a set of important WBV predictors that could be used to develop a statistical instrument for exposure assessment in a large epidemiologic study, a total of 432 WBV measures were taken from a sample of 247 male drivers in Taipei City, Taiwan. In accordance with the ISO 2631-1 (1997) methods, we measured the frequency-weighted vertical acceleration (z-axis) over drivers' seat surface, under conditions representing different types of rides (vacant vs. short vs. long) assigned to random destinations. Mixed effect models were used to analyse the WBV data including repeated measures. For this group of urban taxi drivers regularly exposed to WBV of low intensity (mean = 0.31 ms( - 2), ranging from 0.17 to 0.55 ms( - 2) r.m.s.), our analyses indicated that average driving speed was the primary predictor (p < 0.0001). As average driving speed increased, measured vertical acceleration increased in a quadratic-linear manner (p < 0.0001). Other WBV predictors, after adjusting for the effects of other covariates, included automobile manufacturer (p = 0.02), engine size (p = 0.04), body weight (p = 0.002), age (p = 0.02), use of seat cushion (p = 0.03), and traffic period (p = 0.02). Our study suggests that a similar statistical approach could be employed in future studies to improve the quality and efficiency of WBV exposure assessment in professional drivers.

Acceleration↗

Haptic force-feedback devices for the office computer: performance and musculoskeletal loading issues.

Pointing devices, essential input tools for the graphical user interface (GUI) of desktop computers, require precise motor control and dexterity to use. Haptic force-feedback devices provide the human operator with tactile cues, adding the sense of touch to existing visual and auditory interfaces. However, the performance enhancements, comfort, and possible musculoskeletal loading of using a force-feedback device in an office environment are unknown. Hypothesizing that the time to perform a task and the self-reported pain and discomfort of the task improve with the addition of force feedback, 26 people ranging in age from 22 to 44 years performed a point-and-click task 540 times with and without an attractive force field surrounding the desired target. The point-and-click movements were approximately 25% faster with the addition of force feedback (paired t-tests, p < 0.001). Perceived user discomfort and pain, as measured through a questionnaire, were also smaller with the addition of force feedback (p < 0.001). However, this difference decreased as additional distracting force fields were added to the task environment, simulating a more realistic work situation. These results suggest that for a given task, use of a force-feedback device improves performance, and potentially reduces musculoskeletal loading during mouse use. Actual or potential applications of this research include human-computer interface design, specifically that of the pointing device extensively used for the graphical user interface.

Adult↗

In vivo finger flexor tendon force while tapping on a keyswitch.

Force may be a risk factor for musculoskeletal disorders of the upper extremity associated with typing and keying. However, the internal finger flexor tendon forces and their relationship to fingertip forces during rapid tapping on a keyswitch have not yet been measured in vivo. During the open carpal tunnel release surgery of five human subjects, a tendon-force transducer was inserted on the flexor digitorum superficialis of the long finger. During surgery, subjects tapped with the long finger on a computer keyswitch, instrumented with a keycap load cell. The average tendon maximum forces during a keystroke ranged from 8.3 to 16.6 N (mean = 12.9 N, SD = 3.3 N) for the subjects, four to seven times larger than the maximum forces observed at the fingertip. Tendon forces estimated from an isometric tendon-force model were only one to two times larger than tip force, significantly less than the observed tendon forces (p = 0.001). The force histories of the tendon during a keystroke were not proportional to fingertip force. First, the tendon-force histories did not contain the high-frequency fingertip force components observed as the tip impacts with the end of key travel. Instead, tendon tension during a keystroke continued to increase throughout the impact. Second, following the maximum keycap force, tendon tension during a keystroke decreased more slowly than fingertip force, remaining elevated approximately twice as long as the fingertip force. The prolonged elevation of tendon forces may be the result of residual eccentric muscle contraction or passive muscle forces, or both, which are additive to increasing extensor activity during the release phase of the keystroke.

Adult↗

Control strategies for finger movement during touch-typing. The role of the extrinsic muscles during a keystroke.

A single keystroke during touch-typing is a rapid, goal-directed motion of the fingertip which consists of two single-direction movements. The neural control and the role of the finger extrinsic musculature during typing have not yet been explained. The fingertip motion and force, and the intramuscular electromyographic (EMG) activity (fine-wire) of the index finger extrinsic musculature were measured during touch-typing by ten experienced typists. The motions and forces were repeatable qualitatively across keystrokes. A three-burst EMG pattern was observed during a single keystroke. The three bursts were: (1) a burst of extensor activity lifted the finger before the keystroke; (2) a burst of flexor activity followed while the fingertip was moving downward; and (3) a second burst of extensor activity occurred as the fingertip reached the end of key travel. The timing of the third burst suggests the role of the extensors is to remove the fingertip from the keyswitch rather than stop the downward motion of the finger. The collision with the end of key travel stops the downward finger motion. The timing of the finger flexor EMG activity, burst 2, suggests that the flexor contraction principally overcomes the activation force of the keyswitch rather than accelerates the finger downward as expected.

Adult↗

Tensions of the flexor digitorum superficialis are higher than a current model predicts.

Existing isometric force models can be used to predict tension in the finger flexor tendon, however, they assume a specific distribution of forces across the tendons of the fingers. These assumptions have not been validated or explored by experimental methods. To determine if the force distributions repeatably follow one pattern the in vivo tension of the flexor digitorum superficialis (FDS) tendon of the long finger was measured in nine patients undergoing open carpal tunnel release surgery. Following the release, a tendon force transducer (Dennerlein et al. 1997 J. Biomechanics 30(4), 395-397) was mounted onto the FDS of the long finger. Tension in the tendon, contact force at the fingertip, and finger posture were recorded while the patient gradually increased the force applied by the fingertip from 0 to 10 N and then monotonically reduced it to 0 N. The average ratio of the tendon tension to the fingertip contact force ranged from 1.7 to 5.8 (mean = 3.3, s.d. = 1.4) for the nine subjects. These ratios are larger than ratios predicted by current isometric tendon force models (mean = 1.2, s. d. = 0.4). Subjects who used a pulp pinch posture (hyper-extended distal interphalangeal joint (DIP)) showed a significantly (p = 0.02) larger ratio (mean = 4.4, s.d. = 1.5) than the five subjects who flexed the DIP joint in a tip pinch posture (mean = 2.4, s.d. = 0.6). A new DIP constraint model, which selects different force distribution based on DIP joint posture, predicts force ratios that correlate well with the measured ratios (r2 = 0.85).

Adult↗

A low profile human tendon force transducer: the influence of tendon thickness on calibration.

An in vitro calibration method for human tendon force transducers using tendon thickness to predict the calibration factor has been previously proposed (An et al., 1990, J. Biomechanics 23, 1269-1271). However, changes in the calibration factor due to changing tendon geometry during repeated tendon loading are unknown. A new, low-profile transducer design that measures tendon thickness in the transducer, in situ, is developed. An empirical model estimating the transducer's calibration factor is developed using data from in vitro tension testing of 12 fresh frozen human finger flexor tendons. Each tendon is preseated with ten loading cycles before data collection. Using tendon thickness, the model predicts the measured calibration factor to within 0-15% (average 6%). During repeated loading of an in vitro tendon, the calibration factor changes 15% over the first ten cycles (0-50 N) due to the observed changing tendon thickness. After the first ten loading cycles the variability of the calibration factor is reduced to less than 1% for the next three loading cycles. Hence this new, modified in vitro calibration procedure with tendon preseating reduces the cycle-to-cycle variability caused by the associated change in the tendon thickness.

Calibration↗