Pulmonary function tests cannot predict exercise-induced hypoxemia in chronic obstructive pulmonary disease.

We studied 40 patients with chronic obstructive pulmonary disease (COPD) to determine whether measurements of pulmonary function could predict a fall in arterial oxygen pressure (PaO2) with exercise. The PaO2 fell more than 3 mm Hg in 21 patients (group 1), did not change (+/- 3 mm Hg) in nine patients (group 2), and increased more than 3 mm Hg in ten patients (group 3). Group 3 had significantly less severe expiratory obstruction than groups 1 and 2. The most significant variables in predicting a change in PaO2 with exercise were the ratio of the forced expiratory volume in one second over the forced vital capacity (FEV1/FVC) and the single-breath carbon monoxide diffusing capacity (Dsb). Measurements of FEV1/FVC of 0.50 or more and Dsb of 20 ml/min/mm Hg or more were 100 percent predictive in excluding a fall in PaO2 with exercise. Measurements below these thresholds could not be used reliably to predict which patients would develop worsening hypoxemia with exercise. Because of wide variability in reference values from eight different published studies for diffusing capacity, recommended criteria based on the percent predicted Dsb should be used with caution. We conclude that pulmonary function measurements cannot be used to predict exercise-induced hypoxemia in patients with COPD; however, the measurements may be useful in identifying patients whose condition is less severe who are unlikely to develop worsening hypoxemia with exercise.

Carbon Dioxide

Accuracy of two ear oximeters at rest and during exercise in pulmonary patients.

The accuracy of 2 ear oximeters (Hewlett-Packard 47201A and Biox IIA) was evaluated at rest and during exercise in 116 pulmonary patients. Ear oximetry measurements were compared with arterial oxygen saturation (SaO2) measured from simultaneous arterial blood samples. When used according to the manufacturer's instructions for stabilization during exercise testing, both oximeters demonstrated comparable accuracy in estimating arterial blood SaO2 both at rest and during exercise in these patients (95% confidence limits, 2 SEE = +/- 4 to 5%). The oximeters were more accurate in measuring a change in SaO2 from a previous reading (95% confidence limits, 2 SEE = +/- 2.5 to 3.5%). COHgb levels greater than 4% and dark skin pigmentation appeared to decrease the accuracy of ear oximetry measurements. Within the limitations of accuracy, both ear oximeters may be useful for clinical exercise testing in pulmonary patients.

Arteries