PubMed HealthSearch

Biomedical subjects

J T Mao

Publications and source records attributed to J T Mao.

6 recordsLinked to original sources

A clinically viable technique of fat suppression for abdomen and pelvis.

Chemical-shift selective imaging with an improved selective presaturation pulse can be used to suppress the fat signal uniformly across the entire abdominal cavity. The required magnetic field homogeneity is no higher than for a routine diagnostic scan. Therefore, no extra setup time for shimming is needed. The technique has been implemented on our clinical system for routine fat suppression scans.

Abdomen

The relation of low frequency restoration methods to the Gerchberg-Papoulis algorithm.

In magnetic resonance imaging, low frequency components can be allowed to saturate the analog to digital converter to reduce the quantization noise. These components can be estimated using least squares error estimation based low frequency restoration methods or the iterative Gerchberg-Papoulis algorithm. In this paper, we show the relationship between the closed form estimation methods and the iterative algorithm, propose a method for improving the speed of iteration, and discuss the advantages and disadvantages of two types of methods.

Algorithms

Spatial mapping of 23Na NMR signals by two-dimensional rotating frame imaging.

The reconstruction of two-dimensional spatial images with 0.5-mm resolution using radiofrequency gradients generated by an NMR coil system rotated about the sample is demonstrated for 23Na. The method retains chemical shift, should be capable of mapping T1 and T2 information, and might offer sensitivity advantages for nuclides with short T2.

Humans

Slice profile improvement for a clinical MRI system.

Optimal control methods have been recently introduced to improve the design of selective radio frequency pulses and several optimized selective pulses that can produce excellent slice profiles have been reported. These pulses usually require high peak rf amplitudes to implement and thus can not be widely utilized because of the limitations of the specific absorption rate and the rf power amplifier of a clinical system. We have a Siemens 1.5 T MRI clinical system. Several pulse files which consist of the bandwidth matched 90 degrees and 180 degrees selective pulses are provided. Some of these can produce excellent slice profiles. However, they can only be used in the pulse sequences with the pulse length of 5.12 msec. The purpose of this paper is to improve the slice profiles produced by the pulse file in the pulse sequences with the shorter 2.56 msec pulse length. A pulse file optimized by the conjugate gradient method is proposed to substitute the 2.56 msec Siemens pulse file. Our experimental results confirm that the slice profiles and images are improved by the optimized pulse file with a lower peak voltage. The proposed pulse file can also be applied in other clinical MRI systems.

Magnetic Resonance Imaging

Selective Fourier transform localization.

We have introduced the selective Fourier transform technique for spectral localization. This technique allows the acquisition of a high-resolution spectrum from a selectable location with control over the shape and size of the spatial response function. The shape and size of the spatial response are defined during data acquisition and the location is selectable through processing after the data acquisition is complete. The technique uses pulsed-field-gradient phase encoding to define the spatial coordinates. In this paper the theoretical basis of the selective Fourier transform technique is developed and experimental results are presented, including comparisons of spectral localization using either the selective Fourier transform method or conventional multidimensional Fourier transform chemical-shift imaging.

Fourier Analysis

Estrogen induction of plasma vitellogenin in the cockerel: studies with a phosvitin antibody.

The effects of estrogen on plasma vitellogenin have been studied in the cockerel by immunoprecipitation techniques using an antiserum prepared against the egg yolk phosphoprotein, phosvitin. The antiserum gave precipitin lines of complete identity to phosvitin and to vitellogenin which was isolated from hen plasma by DEAE-cellulose chromatography and by affinity chromatography using anti-phosvitin coupled to Sepharose 4B. The cross-reactivity of vitellogenin and phosvitin adds support to the concept that plasma vitellogenin is the precursor phosphoprotein of egg yolk phosvitin. In the three-week old cockerel, anti-phosvitin produced no detectable immunoprecipitate in the plasma. However, after a single sc injection of diethylstilbestrol (2.5 mg), plasma vitellogenin levels began to increase at 4 h and reached a maximum 20-30 h after hormone administration. The increase in plasma levels of triglyceride paralleled those of vitellogenin. These studies suggest that there is no significant time lag in the estrogenic induction of plasma vitellogenesis in the cockerel, the longer lag periods observed by other investigators may be a function of the sensitivity of the assays used for detecting vitellogenin.

Amino Acids