PubMed Health⌕ Search

Biomedical subjects

J T Noteboom

Publications and source records attributed to J T Noteboom.

3 recordsLinked to original sources

Precision-grip force changes in the anatomical and prosthetic limb during predictable load increases.

This study examined precision-grip force applied to an instrumented test object held aloft while the weight of the object was predictably varied by transporting and placing loads (50, 100, or 200 g) atop the test object. Transport of the loads was performed either by the subject or the experimenter. Grip force was examined in four non-amputee control subjects and in the anatomical and prosthetic hand of a subject with a prosthetic device. As subjects transported the load, anticipatory grip-force changes occurred in the anatomical hands and prosthetic hand, which were scaled in relation to the load. When the experimenter transported the load to the anatomical hands of control subjects or the prosthetic user, anticipatory increases in grip force occurred that also were scaled in relation to load. However, when the experimenter transported the load to the prosthetic hand, anticipatory grip-force adjustments were absent. During the phase in which the load was being assumed by the postural hand, grip forces in the anatomical hands and prosthetic hand were further scaled to load demands. Ability to adapt grip force in the prosthetic hand during this phase suggested that the subject was utilizing sensory information from the residual limb to adjust grip force. Thus, while anticipatory changes precede the process of adaptation to load changes, actual sensory consequences resulting from added weight remain necessary to fully adapt grip force to load demands, even for the prosthetic user.

Adaptation, Physiological↗

Bilateral simultaneous infrapatellar tendon ruptures: a case study.

This case study reports on a patient with a diagnosis of bilateral patellar tendon ruptures. Bilateral ruptures of the infrapatellar tendons are rare occurrences; approximately 20 cases have been reported in the medical literature. Much of the medical literature concentrates on surgical repair, immediate postoperative follow-up, and final outcome. There is a void in the literature concerning the rehabilitative process of these patients. The subject of this study is a 26-year-old male former collegiate athlete who suffered simultaneous bilateral patellar tendon ruptures while jumping. A rehabilitation model is provided that may assist others treating patients with similar conditions.

Adult↗

Effects of electrical and electromagnetic stimulation after anterior cruciate ligament reconstruction.

A need exists to develop new methods of neuromuscular electrical stimulation (NMES) that are both effective and relatively pain-free. The purpose of this pilot study was to determine the effects of both NMES and a new method of electromagnetic (NMES/PEMF) stimulation for reducing girth loss and for reducing pain and muscle weakness of the knee extensor muscles in patients during the first 6 weeks after reconstructive surgery of the anterior cruciate ligament (ACL). Seventeen patients receiving ACL reconstructive surgery participated as a control group (N = 3), as an NMES group (N = 7), and with combined NMES and magnetic field stimulation (NMES/PEMF) (N = 7). Patients receiving NMES/PEMF rated each type of stimulation for perceived pain and were measured for their torque. Torque results revealed a mean decrease of 13.1% for NMES/PEMF patients. The mean percent of thigh girth decreased 8.3% for controls, 0.5% for NMES, and 2.3% for NMES/PEMF patients. The NMES/PEMF patients rated NMES as causing about twice the pain intensity as NMES/PEMF during treatments. As a result of this data, the authors conclude that both NMES and NMES/PEMF are effective in reducing girth loss and that NMES/PEMF is less painful than NMES alone in treating patients after ACL reconstruction.

Adolescent↗