PubMed Health⌕ Search

Biomedical subjects

J T Reilly

Publications and source records attributed to J T Reilly.

At least 37 records · Page 2Linked to original sources

Low level leucocyte counting: a critical variable in the validation of leucodepleted blood transfusion components as highlighted by an external quality assessment study.

Leucocyte counts of < 5 x 106 per blood transfusion product are currently recommended in the UK in order to reduce transfusion-related infections and febrile reactions. Routine leucocyte depletion, however, requires the development of reliable internal and external quality assurance (EQA) programmes. We report preliminary findings from the UK NEQAS for Low-Level Leucocyte Counting from 18 UK Transfusion Centres over a four month period. Data analysis showed that the IMAGN 2000 had the lowest CVs (range 7.5-36%, mean 16.7) for samples with counts of 5-30 cells/microl when compared to the flow cytometric (range 13.8-88%, mean 29.5) and Nageotte methods (range 20.6-117%, mean 61.8). In addition, laboratories using commercial nuclear stains (LeucoCOUNTTM) had consistently lower CVs than those using 'in-house' propidium iodide staining methods. Important differences in flow cytometric gating strategies were also identified. This study highlights the current variability in low level leucocyte counting, especially within the critical range of 5-30 cells/microl (equating to < 5 x 106/l). The acceptance of consensus protocols, including gating strategies and nuclear staining techniques, is required to reduce the observed interlaboratory variation. Finally, we demonstrate that stabilized blood preparations can be successfully used to provide a national/international low-level leucocyte EQA scheme.

Blood Component Transfusion↗

UK NEQAS for leucocyte immunophenotyping: the first 10 years.

In the past decade, cellular immunophenotyping has become a new discipline in diagnostic haematology and immunology, and is invaluable in the rapid diagnosis of leukaemia and monitoring disease progression in human immunodeficiency virus infected individuals. The introduction of bench top flow cytometers has meant that immunophenotyping is now also used for the quantitation of CD34(+) peripheral blood stem cells (PBSCs) to ensure the correct timing and adequacy of haematopoietic progenitor cell harvests. Furthermore, flow cytometry has become an important tool for the counting of leucocytes in blood components after leucocyte depletion. Because this new discipline is now such a major diagnostic and prognostic tool in the clinical arena, its use must be subject to both internal and external quality control. Such a requirement was first recognised as early as 1986 when an Inter-Regional Quality Assessment Scheme (IRQAS) was initiated for laboratories that undertook the immunocytochemical diagnosis of leukaemia using the alkaline phosphates anti-alkaline phosphatase technique. This programme began with around 25 UK laboratories. In 1990, after the introduction of two more programmes (one for leukaemia diagnosis using UV microscopy and latterly flow cytometry, and one for the enumeration of CD4(+) T cells) the IRQAS achieved UK National External Quality Assessment Scheme (UK NEQAS) status and changed its title to UK NEQAS for Leucocyte Immunophenotyping. In the past decade the once small IRQAS programme has evolved into the largest international scheme of its kind, providing EQA to over 650 laboratories world wide for leukaemia immunophenotyping, lymphocyte subset analysis, PBSCs, and more recently low level leucocyte counting. Over the years, this EQA programme has highlighted important problems, such as the inappropriate use of fluorochromes and antibody titre, and the identification of effective gating strategies, all of which have contributed directly to the high interlaboratory variations seen in cellular immunophenotyping. Furthermore, particularly in absolute counting of lymphocyte subsets, PBSCs, and the enumeration of low numbers of leucocytes, UK NEQAS for Leucocyte Immunophenotyping programmes have been instrumental in highlighting the differences that occur between single and dual platform flow cytometric technologies. As a result of these findings, UK NEQAS for Leucocyte Immunophenotyping has helped to reduce the variation seen on an interlaboratory basis and enabled greater standardisation both in the UK and internationally. These advances have been attributable to the development, by UK NEQAS for Leucocyte Immunophenotyping, of a unique whole blood stabilising process that ensures the retention of the physical characteristics (both light scatter and antigenic profile) required of cells to ensure successful cellular immunophenotyping. This major technological advancement has enabled the distribution of specimens for EQA purposes on a global scale that have minimal matrix effect and behave in a manner identical to fresh blood for several months after stabilisation.

Antigens, CD34↗

Reduction of intra- and interlaboratory variation in CD34+ stem cell enumeration using stable test material, standard protocols and targeted training. DK34 Task Force of the European Working Group of Clinical Cell Analysis (EWGCCA).

The European Working Group on Clinical Cell Analysis (EWGCCA) has, in preparation for a multicentre peripheral blood stem cell clinical trial, developed a single-platform flow cytometric protocol for the enumeration of CD34+ stem cells. Using this protocol, stabilized blood and targeted training, the EWGCCA have attempted to standardize CD34+ stem cell enumeration across 24 clinical sites. Results were directly compared with participants in the UK National External Quality Assessment Scheme (NEQAS) for CD34+ Stem Cell Quantification that analysed the same specimens using non-standardized methods. Two bead-counting systems, Flow-Count and TruCount, were also evaluated by the EWGCCA participants during trials 2 and 3. Using Flow-Count, the intralaboratory coefficient of variation (CV) was </= 5% in 39% of the laboratories (trial 1), increasing to 65% by trial 3. Interlaboratory variation was reduced from 23.3% (trial 1) to 10.8% in trial 3. In trial 2, 70% of laboratories achieved an intralaboratory CV </= 5% using TruCount, increasing to 74% for trial 3; the interlaboratory CV was reduced from 23.4% to 9.5%. Comparative analysis of the EWGCCA and the UK NEQAS cohorts revealed that EWGCCA laboratories, using the standardized approach, had lower interlaboratory variation. Thus, the use of a common standardized protocol and targeted training significantly reduced intra- and interlaboratory CD34+ cell count variation.

Antigens, CD34↗

FLT3 internal tandem duplication mutations in adult acute myeloid leukaemia define a high-risk group.

Genomic DNA from 106 cases of adult de novo acute myeloid leukaemia (AML) was screened by polymerase chain reaction (PCR) and gel electrophoresis for FLT3 internal tandem duplication (ITD) mutations within the juxtamembrane (JM) domain. FLT3 mutations were detected in 14 cases (13.2%) and occurred in FAB types M1 (4 out of 14 cases), M3 (1 out of 10 cases), M4 (5 out of 37 cases) and M5 (4 out of 11 cases). Sequence analysis of four cases with abnormal PCR electrophoretic patterns revealed in frame duplications in the region of exon 11 of between 27 and 111 base pairs. Three are predicted to result in the tandem duplication of adjacent amino acid residues and one to result in a tandem duplication plus insertion of a novel amino acid motif. Statistical analysis showed the FLT3 mutations to be a strong prognostic factor, with patients lacking the mutation surviving significantly longer from diagnosis (mean 29.1 months) than those with an ITD (mean 12.8 months; P = 0.0002). Thirteen of the 14 patients with FLT3 mutations died within 18 months of diagnosis. FLT3 mutations were of prognostic significance in good risk disease (P = 0.04), as well as in patients with standard risk disease (P = 0.0096). This study demonstrates that the FLT3 ITD mutation occurs in a significant percentage of adult AML cases and is an important adverse prognostic factor that appears independent of conventional karyotypic findings.

Acute Disease↗

Are aberrant BCR--ABL transcripts more common than previously thought?

We report the use of multiplex polymerase chain reaction (PCR), using 4% polyacrylamide gel electrophoresis (PAGE) for the detection of BCR-ABL transcripts in Philadelphia-positive disease. Three out of 50 cases [two out of 37 chronic myeloid leukaemia (CML), one out of 13 acute lymphoblastic leukaemia (ALL)] possessed rare breakpoints; an e19a2 and e13a3 in CML and an e1a3 in the ALL. We suggest that multiplex PCR using 4% PAGE and optimized for smaller transcript detection may lead to a higher detection rate of rare BCR-ABL breakpoints. Multiplex PCR, however, failed to distinguish e13a2 from e1a3 transcripts. Finally, the presence of e13a3 in CML supports the view that abl exon 2 sequences are unnecessary for the pathogenesis of 'classic' CML.

Chromosome Breakage↗

Cytogenetically cryptic AML1-ETO and CBF beta-MYH11 gene rearrangements: incidence in 412 cases of acute myeloid leukaemia.

The rearrangements t(8;21)(q22;22) and inv(16)(p13q22) are two of the most frequently seen in acute myeloid leukaemia (AML), accounting for 8% and 4% of cases respectively. Detection of these abnormalities is important for disease management as both are associated with good responses to conventional chemotherapy and prolonged disease-free survival. Recent reports using reverse transcriptase polymerase chain reaction (RT-PCR) suggest that significant proportions of AML cases without a visible t(8;21) or inv(16) show expression of an abnormal fusion gene transcript and, consequently, they could not be detected using conventional cytogenetic analysis alone. We present here a four centre study involving 412 cases of AML screened using both standard cytogenetics and RT-PCR for AML1-ETO and CBF beta-MYH11. We detected a cytogenetic t(8;21) in 31 out of 412 (7.5%) cases and an inv(16) or t(16;16) variant in 27 out of 412 (6.6%) cases. RT-PCR detected only two cases (0.5%) of cryptic t(8;21) and no instances of cryptic inv(16). Both cryptic t(8;21) cases had the classic M2 FAB morphology for this type of disease. Our data concur with the established FAB type distribution of the rearrangements and indicate that cryptic t(8;21) and inv(16) may be much less frequent than reported elsewhere.

Acute Disease↗

Standardization of lymphocyte antibody binding capacity - a multi-centre study.

As quantitative flow cytometry is being increasingly used to characterize non-malignant and malignant disorders, interlaboratory standardization becomes an important issue. However, the lack of standardized methods and process controls with predefined antibody binding capacity values, limits direct interlaboratory comparison. The present study has addressed these issues using a stable whole blood product and a standardized antigen quantification protocol. It was demonstrated that: (i) a standard technical protocol can result in a high degree of interlaboratory concordance; (ii) interlaboratory variation of less than 12% can be achieved for CD4 antibody binding capacity values; and (iii) stable whole blood can be used as a process control with predefined antibody binding capacity values. Furthermore, using such an approach, a normal range was established for CD3, CD4 CD8 and CD19. These antigens appear to be expressed in a hierarchical manner, a factor that could be used as a procedural quality control measure.

Antigens, CD↗

Autoimmune thrombocytopenia: a complication of fludarabine therapy in lymphoproliferative disorders.

We describe two cases of autoimmune thrombocytopenia precipitated by fludarabine therapy in patients with chronic lymphatic leukaemia. Both were treated with high dose steroids and initially responded with recovery of normal platelet counts. One patient developed recurrent autoimmune thrombocytopenia on two occasions following re-exposure to the drug when his disease had become refractory to all other treatments. A retrospective review of the case notes of 45 patients with lymphoproliferative disorders treated with fludarabine over the past 6 years indicated the development of autoimmune thrombocytopenia in 4.5% (two out of 45) and autoimmune haemolytic anaemia in 6.7% (three of the 45).

Adult↗

Scrotal ulceration during all-trans retinoic (ATRA) therapy for acute promyelocytic leukaemia.

We report the development of painful scrotal ulceration in two patients during treatment with all-trans-retinoic acid (ATRA) for acute promyelocytic leukaemia (APL). ATRA 45 mg/m2 was administered orally for 8 days prior to the addition of standard induction chemotherapy. Painful scrotal ulceration developed in both cases within 2 weeks of therapy (9 and 13 days) and responded slowly to drug withdrawal and systemic, or topical, corticosteroids. A total of 17 APL patients have been treated with ATRA at our institution during the last 10 years, giving an incidence of approximately 12%. The present report, together with a review of literature, suggests that scrotal ulceration is a specific adverse effect of ATRA therapy and that this complication may be more common than previously documented.

Adrenal Cortex Hormones↗

Absolute CD4+ T-lymphocyte and CD34+ stem cell counts by single-platform flow cytometry: the way forward.

To determine the potential advantage of single-platform technology in the enumeration of CD4+ T lymphocyte and CD34+ stem cells, data has been analysed from the UK NEQAS for Leucocyte Immunophenotyping schemes. The inter-laboratory CVs for CD4+ T lymphocyte counts were consistently lower for single-platform (mean 13.7%, range 10-18.3%) compared to dual-platform methodology (mean 23.4%, range 14.5-43.7%). Subgroup analysis of single-platform users demonstrated mean overall inter-laboratory CVs of 17.2%, 13% and 7.1% for the FlowCount, TruCount and volumetric approach respectively. The lowest inter-laboratory CVs obtained for a single sample by each single platform approach were 4% (TruCount), 4.4% (volumetric), 4.6% (FACSCount) and 12.7% (FlowCount). Similarly, the mean inter-laboratory CV for CD34+ stem cell enumeration using non-standardized single-platform approaches was 18.6% (range 3.1-36.9%) compared to 28.6% (range 19-44.2%) for the dual-platform technology. Our results suggest absolute cell subset enumeration should be performed by single-platform technology and that such an approach should improve the quality control of multi-centre clinical trial data for CD4+ T lymphocyte and CD34+ stem cells.

Antigens, CD34↗

Pathogenesis and management of idiopathic myelofibrosis.

Idiopathic myelofibrosis is the least common and carries the worst prognosis of the chronic myeloproliferative disorders. The primary disease process is a clonal haematopoietic stem cell disorder which results in a chronic myeloproliferation and an atypical megakaryocyte hyperplasia. In contrast, the characteristic stromal proliferation is a reactive phenomenon, resulting from the inappropriate release of megakaryocyte/platelet-derived growth factors, including PDGF, TGF-beta bFGF and calmodulin. The median survival is approximately 4 years, although individual survival varies greatly. A variety of prognostic schema have been developed which enable the identification of high-risk patients, for whom bone marrow transplantation should be considered. Management for the majority of patients, however, is directed towards the alleviation of symptoms and improvement in quality of life. This review summarizes the recent advances in our understanding of the disease's pathogenesis and discusses the limited therapeutic options available to clinicians.

Anemia↗

Quality assessment of CD34+ stem cell enumeration: experience of the United Kingdom National External Quality Assessment Scheme (UK NEQAS) using a unique stable whole blood preparation.

CD34+ peripheral blood stem cell (PBSC) mobilization and harvesting has rapidly replaced autologous bone marrow as a source of stem cells for transplantation. Timing and adequacy of harvests rely upon the accurate enumeration of circulating CD34+ cells. However, previous EQA programmes have reported interlaboratory CVs as high as 284%, suggesting the need for greater standardization. In addition the routine use of fresh and/or frozen cells as analytes also introduces antigen instability as a variable factor. To circumvent this problem and achieve a true reflection of interlaboratory variation, we have used a novel whole blood preparation in which the antigenic profiles of PBSCs, as determined by flow cytometry, are retained for > 200 d. This international scheme, currently the largest in the world, distributes aliquots of stabilized whole blood bi-monthly to 91 laboratories in 20 countries (44 U.K., 47 overseas). Participants are required to determine the percentage and absolute values for CD34+ PBSCs using in-house techniques. Adopting such a preparation, a more accurate determination of interlaboratory variation has been possible when compared to previous EQA studies, with CVs as low as 22% and 24% for percentage and absolute counts. In addition the programme has established that a wide range of methods are in routine use, emphasizing the urgent requirement for national/international consensus guidelines.

Antigens, CD34↗

Determination of leucocyte antibody binding capacity (ABC): the need for standardization.

The flow cytometric determination of antigen density, or cellular antibody binding capacity, is now an accepted technique for the characterization of cells in health and disease. In HIV infection, for example, antigen density changes in CD38 expression may be an important indicator of disease progression. Our experience of using one such method, Quantum Simply Cellular, which measures antibody binding capacity (ABC), has highlighted several technical factors which can affect the results. We report the influence of pH, incubation temperature and time, antibody fluorochrome and titre, as well as lysing reagent (FACS Lysing Solution v. Ortho-mune Lysing Reagent) on the ABC of anti-CD3, CD4 and CD8 of normal lymphocytes. In addition, the effect of single, double or triple-staining was assessed. The results indicate that the ABC values are influenced by all the variables studied. The pH range tested (6.0-9.0) demonstrated that pH 7.4 gave maximal binding. Furthermore, temperature also influenced the pH of the two lysing solutions, and thus potentially the ABC. Antibody concentration, fluorochrome and staining technique are also important factors with an observed difference of up to 458,855 ABC between the various fluorochromes. In addition a maximal difference of 130,119 ABC was observed between single and triple staining techniques. In conclusion, if antigen quantification is to be used in the clinical setting, an internationally standardized method is required to ensure the reproducibility of results from centre to centre. Our data suggests that single staining, using fluorescein isothiocynate (FITC) conjugated antibodies with all reagents at pH 7.4 + 0.1, with incubation and lysing carried out at 20 + 1 degrees C, could be used as a 'benchmark' method for ABC determination using the QSC system.

Antigen-Antibody Reactions↗

Efficacy of urate oxidase (uricozyme) in tumour lysis induced urate nephropathy.

Urate oxidase (uricozyme) is an enzyme of non-human origin capable of oxidizing human uric acid to allantoin, a highly soluble product at renal tubule pH. We report its efficacy in three patients with acute urate nephropathy due to tumour lysis in chronic lymphatic leukaemia and high grade lymphoma. Two patients had an additional obstructive nephropathy due to ureteric urate crystals. An intravenous infusion (100 units/kg in 50 ml saline over 30 min) was given for between two and five consecutive days. All patients showed a rapid fall in serum urate levels with associated diuresis, correction of metabolic disturbance and full resolution of uraemia within a week. The treatment was well tolerated and caused a rapid resolution of clinical symptoms in all cases. We review the literature relating to the use of this agent both in the treatment of hyperuricaemic acute renal failure and gouty arthritis.

Aged↗