A fluid dynamic analysis using flow visualization of the Baylor/NASA implantable axial flow blood pump for design improvement.

The Baylor/NASA Axial Blood Flow Pump has been developed for use as an implantable left ventricular assist device (LVAD). The pump is intended as an assist device for either pulmonary or systemic circulatory support for more than 3-months' duration. To date the pump provides acceptable results in terms of thrombus formation and hemolysis (IH of 0.018 g/100 L). A fluid dynamics analysis using flow visualization was performed to investigate the flow fields and to determine areas within the pump that could be improved. These studies focused upon the inflow area in front of the pump. A prototype axial flow pump assembly was constructed to facilitate the flow visualization studies. Particle image tracking velocimetry techniques were used to measure Amberlite particles suspended in a blood analog fluid composed of 63% water and 37% glycerin. This method used a pulsed (612 Hz) laser light to determine flow velocity profiles, shear stress, Reynolds numbers, and stagnant areas within the axial pump. These studies showed that the flow straightener (a vaned assembly in the pump inflow) reduced Reynolds numbers from 4,640 to 2,540 (at 8.5 L/min) and that the flow straightener exacerbates a discontinuity found between it and the impeller. Within the inflow area, a maximum of 80 N/m2 shear stress was measured, which is well below published blood damage thresholds. Design variations were investigated resulting in a smoother flow transition between flow straightener and impeller. These variations must be investigated further to establish a correlation with hemolysis and thrombus formation.

Blood Flow Velocity↗

Flow pattern analysis of the Baylor total artificial heart.

To obtain an optimal design of the left blood chamber of the total artificial heart (TAH), flow visualization studies were performed. Information on velocities in critical areas of the left chamber was gathered using sectional pulsed laser light. The flow patterns on the entire pumping duration were photographed frame by frame. The inflow port, the opposite of the inflow and outflow of the pump (bottom area), and the diaphragm/housing junction were the focal areas. The pump conditions, such as chamber pressure, preload and afterload pressure, pumping rate and roller screw, and displacement were recorded. Major stagnations and a low washout effect were observed in the bottom region. The closing of the inflow valve was irregular. In order to solve this problem, the inflow valve angle was changed 20 degrees. A comparison study showed a better valve closing characteristic, and no stagnation areas were observed with this new valve angle. Various velocity profiles confirmed the results. The valve closing characteristics is described in relationship to back flow.

Blood Flow Velocity↗

The Baylor total artificial heart. Flow visualization studies.

To analyze the flow patterns of the left blood chamber of the Baylor total artificial heart (TAH) and to evaluate influences of the inflow valve angle to the flow patterns, flow visualization studies were performed. The inflow valve angle of the left housing was changed by 20 degrees orthogonal to the inflow tube, and comparison studies of the modified and unmodified models were made. For evaluating sectional flow patterns, a laser light was used, the clear transparent housing was scanned segmentally, and flow patterns were recorded on high contrast film for measuring flow velocities. A signal was used that synchronized the timing of the camera shutter to the pusher-plate movement signal. With the modified 20 degree inflow valve direction, there were better closing characteristics of the inflow valve leaflets. At the same time, we could successfully reduce the vortex formation at the inflow port, which may cause thrombus formation. We also have improved the washout during the diastolic phase in not only the bottom area, but in the entire pumping chamber. This flow visualization setup is simple and inexpensive. It is useful not only for validation of global flow patterns, but also for validation of local flow velocities of various blood pumps.

Biomedical Engineering↗