PubMed Health⌕ Search

Biomedical subjects

J Tarning

Publications and source records attributed to J Tarning.

3 recordsLinked to original sources

Characterization of human urinary metabolites of the antimalarial piperaquine.

Five metabolites of the antimalarial piperaquine (PQ) (1,3-bis-[4-(7-chloroquinolyl-4)-piperazinyl-1]-propane) have been identified and their molecular structures characterized. After a p.o. dose of dihydroartemisinin-piperaquine, urine collected over 16 h from two healthy subjects was analyzed using liquid chromatography (LC)/UV, LC/tandem mass spectrometry (MS/MS), Fourier transform ion cyclotron resonance (FTICR)/MS, and H NMR. Five different peaks were recognized as possible metabolites [M1, 320 m/z; M2, M3, and M4, 551 m/z (PQ + 16 m/z); and M5, 567 m/z (PQ + 32 m/z)] using LC/MS/MS with gradient elution. The proposed carboxylic M1 has a theoretical monoisotopic molecular mass of 320.1166 m/z, which is in accordance with the FTICR/MS (320.1168 m/z) findings. The LC/MS/MS results also showed a 551 m/z metabolite (M2) with a distinct difference both in polarity and fragmentation pattern compared with PQ, 7-hydroxypiperaquine, and the other 551 m/z metabolites. We suggest that this is caused by N-oxidation of PQ. The results showed two metabolites (M3 and M4) with a molecular ion at 551 m/z and similar fragmentation pattern as both PQ and 7-hydroxypiperaquine; therefore, they are likely to be hydroxylated PQ metabolites. The molecular structures of M1 and M2 were also confirmed using H NMR. Urinary excretion rate in one subject suggested a terminal elimination half-life of about 53 days for M1. Assuming formation rate-limiting kinetics, this would support recent findings that the terminal elimination half-life of PQ has been underestimated previously.

Antimalarials↗

A new approach to evaluate regression models during validation of bioanalytical assays.

The quality of bioanalytical data is highly dependent on using an appropriate regression model for calibration curves. Non-weighted linear regression has traditionally been used but is not necessarily the optimal model. Bioanalytical assays generally benefit from using either data transformation and/or weighting since variance normally increases with concentration. A data set with calibrators ranging from 9 to 10000 ng/mL was used to compare a new approach with the traditional approach for selecting an optimal regression model. The new approach used a combination of relative residuals at each calibration level together with precision and accuracy of independent quality control samples over 4 days to select and justify the best regression model. The results showed that log-log transformation without weighting was the simplest model to fit the calibration data and ensure good predictability for this data set.

Algorithms↗

Development and validation of an automated solid phase extraction and liquid chromatographic method for the determination of piperaquine in urine.

A sensitive and specific bioanalytical method for determination of piperaquine in urine by automated solid-phase extraction (SPE) and liquid chromatography (LC) has been developed and validated. Buffered urine samples (containing internal standard) were loaded onto mixed phase (cation-exchange and octylsilica) SPE columns using an ASPEC XL SPE robot. Chromatographic separation was achieved on a Chromolith Performance RP-18e (100 mm x 4.6 mm I.D.) LC column with phosphate buffer (pH 2.5; 0.1 mol/L)-acetonitrile (92:8, v/v). Piperaquine was analysed at a flow rate of 3 mL/min with UV detection at 347 nm. A linear regression model on log-log transformed data was used for quantification. Within-day precision for piperaquine was 1.3% at 5000 ng/mL and 6.6% at 50 ng/mL. Between-day precision for piperaquine was 3.7% at 5000 ng/mL and 7.2% at 50 ng/mL. Total-assay precision for piperaquine over 4 days using five replicates each day (n = 20) was 4.0%, 5.2% and 9.8% at 5000, 500 and 50 ng/mL, respectively. The lower limit of quantification (LLOQ) was set to 3 ng/mL using 1 mL of urine, which could be lowered to 0.33 ng/mL when using 9 mL of urine and an increased injection volume.

Animals↗