Flow, radiofrequency pulse sequences, and gradient magnetic fields: basic interactions and adaptations to angiographic imaging.

The basic process of MRI consists of two essential, relatively independent components: (1) excitation in the form of a radiofrequency pulse sequence, and (2) signal sampling and localization, that is, forming the MR image through the use of field gradients. The presence of motion (blood flow) during either excitation or sampling results in two types of corresponding effects: (1) time-of-flight effects, and (2) spin phase phenomena. These effects can be manipulated through the use of special coils, pulse sequences, gradients, and postprocessing techniques to provide angiographic images in which simple motion provides the basis for contrast.

Cerebral Angiography

Gradient-echo MR imaging of the cervical spine: evaluation of extradural disease.

A prospective study was undertaken on 204 consecutive patients comparing low flip angle gradient-echo and T1-weighted spin-echo techniques in the MR evaluation of cervical extradural disease. Four patient groups were studied with varying gradient-echo TEs (6 or 13 msec) and flip angles (10 degrees or 60 degrees). Images were evaluated independently for contrast behavior and anatomy, then directly compared for conspicuity of lesions. The FLASH sequences (especially with a 10 degrees flip angle) produced better conspicuity of disease in half the imaging time. T1-weighted spin-echo sequences were more sensitive to marrow changes and intradural disease. The short TE sequence (6 msec) did not produce any diagnostic advantage over the longer TE sequence (13 msec). A fast and sensitive MR examination for cervical extradural disease combines a sagittal T1-weighted spin-echo acquisition with sagittal and axial FLASH 10 degrees sequences.

Cervical Vertebrae

Improved sensitivity of proton MR to oxygen-17 as a contrast agent using fast imaging: detection in brain.

The potential utility of H2(17)O as a contrast agent has been demonstrated in biological solutions and isolated tissues but its use has been impaired by the need to run heavily T2-weighted spin-echo images. By choosing an appropriate steady-state free precession experiment sensitive to T1/T2, we have improved the available contrast-to-noise per unit time by more than a factor of 5. This allows easy measurement of the proton effects for concentrations as low as 0.4% H2(17)O in less than 1 min. Injection into small animals produces a marked reduction in the overall image intensity. Consecutive imaging at the rate of one every 52 s has been used to follow the rate of change in brain image intensity immediately after injection.

Animals

Oxygen-17 contrast agents. Fast imaging techniques.

Under physiologic conditions the stable isotope oxygen-17, in the form of O-17 water, lowers the proton T2 of blood, CSF, tissues, and whole organisms. With MRI the resulting changes in intensity can be detected using spin-echo pulse sequences, but much greater sensitivity is achieved in a fraction of the time with a steady-state free precession sequence such as FISP. With this sequence it is possible to detect levels as low as 0.4% Oxygen-17 water in 53 seconds or less.

Contrast Media

The value of fast gradient-echo MR sequences in the evaluation of brain disease.

One-hundred-fifteen patients thought to have intracranial disease were studied with various two-dimensional short repetition time, partial-flip-angle gradient-echo techniques: at 1.0 T, fast low-angle short (FLASH) at 10 degrees and 30 degrees and fast imaging with steady-state precession (FISP) at 60 degrees; at 1.5 T, FLASH 10 degrees, 30 degrees, and 60 degrees, FISP 60 degrees, and contrast-enhanced fast steady state at 60 degrees. These sequences were compared with a T2-weighted spin-echo sequence to determine the relative sensitivities of these techniques in detecting parenchymal lesions. Except for hemorrhagic lesions a substantial number of abnormalities were either not visible or poorly seen on the partial-flip-angle gradient-echo sequences. Minimizing echo time (6-9 msec) to decrease magnetic susceptibility effects did not improve lesion detection. Current usage of two-dimensional gradient-echo techniques for lesion detection is limited, except when calcification or hemorrhage is involved. Their utility may be expanded via the incorporation of three-dimensional techniques and IV contrast agents.

Brain Diseases