The spinal GDNF level is increased after transient spinal cord ischemia in the rat.

Glial cell line-derived neurotrophic factor (GDNF) is known as the most potent neurotrophic factor against injury. We have characterized spinal GDNF changes after ischemia to clarify its possible physiological role against ischemic damage. Spinal ischemia in the rat was produced by cross-clamping of the thoracic aorta together with systemic hypotension. The spinal tissue GDNF level was measured by enzyme-linked immunoabsorbent assay (ELISA) and the localization of GDNF in the tissue was examined by immunohistochemistry. GDNF was increased reaching two peaks after ischemia. The first peak was at 2 hrs after onset of recirculation derived from alpha motor neurons. The second GDNF peak was at 72 hrs provided by astrocytes. These data suggest a necessity of GDNF to increase to protect against ischemic damage, and that activated astrocytes may have an important role in maintaining the GDNF level.

Animals↗

Appropriate method of administration of propofol, fentanyl, and ketamine for patient-controlled sedation and analgesia during extracorporeal shock-wave lithotripsy.

PURPOSE: The aim of this study was to identify the appropriate method for administering propofol, fentanyl, and ketamine (PFK) for patient-controlled sedation and analgesia (PCSA) during extracorporeal shock-wave lithotripsy (ESWL). METHODS: Twenty-one unpremedicated patients were randomly assigned to three groups that received different drug administration regimens. (group 1: low loading dose and high demand bolus, group 2: high loading dose and demand bolus, group 3: high loading dose and low demand bolus). RESULTS: The patients in all groups were hemodynamically stable during ESWL. Oxygen desaturation was recognized in all groups, but was avoided by 2 l.min(-1) of oxygen supply via a nasal prong. The total administration dose of the drugs was significantly higher ( P < 0.05) in group 2 than in groups 1 and 3. The median level of sedation was the same, but the episodes of oversedation were not recognized in group 3 ( P < 0.05). A significant difference in the frequency of episodes of oversedation was found between groups 2 and 3 ( P < 0.05). The results were good or excellent for almost all patients, and were assessed as fair by only one patient in group 2. CONCLUSION: We concluded that the method used for group 3 is the most appropriate for administering PFK for PCSA during ESWL.

Clinical Trial↗

A comparison between low-flow leak test and oxygen flush leak test.

PURPOSE: The clinical efficacy of two methods of preanesthetic leak test,namely the oxygen flush leak test (OFLT) and the low-flow leak test (LFLT), was compared regarding their ability to detect leakage in the anesthesia circuit and their accuracy. METHODS: Examinees comprised 16 staff anesthesiologists and 7 physicians undergoing anesthesia training at our institution. They performed the two leak tests on anesthesia machines with some intentional leaks (0.1-1.0 l.min(-1)). The leakage detection rates (LDR) were analyzed by the chi(2)-test. The ability to detect leaks was measured by recording how many leaks were detected by 50% (LDR(50)) and 95% (LDR(95)) of the examinees. RESULTS: The LDRs in the two tests were significantly different (chi(2)- analysis, P < 0.0001). Both LDR(50) and LDR(95) for the LFLT (0.23 and 0.41 l.min(-1), respectively) were smaller than the values for the OFLT (0.37 and 0.82 l.min(-1), respectively). The sensitivity and specificity of the LFLT (0.97 and 0.84, respectively) were higher than those of the OFLT (0.78 and 0.80, respectively). CONCLUSION: The LFLT was found to be superior to the OFLT regarding leak detection and reliability. We therefore recommend the LFLT for preanesthetic leak testing.

Journal Article↗

[Differential epidural block for definitive diagnosis of snapping hip joint].

Snapping hip joint syndrome is defined as snapping phenomenon accompanied by motion of the hip joint. It occurs from various causes, and its diagnosis and treatment are often difficult. We gave anesthesia for surgery against snapping hip joint under patient's active motion for definitive regional diagnosis. Differential epidural block, which precludes pain while maintaining motor function, was performed by 0.25% bupivacaine, 0.5% lidocaine, and additional administration of fentanyl by 25 micrograms. Although the mechanism of differential nerve block remains to be unknown, the case suggests that effective pain block preserving motor function may be achieved by differential epidural block in combination with low concentration of local anesthetics and small dose of opioid.

Adult↗

[Patient-controlled sedation in a patient with respiratory dysfunction for reconstructive surgery of submandibular fracture under local anesthesia].

A 70-year-old male with respiratory dysfunction, chronic obstructive pulmonary disease associated with asthmatic component, received patient-controlled sedation (PCS) using propofol for reconstructive surgery of submandibular fracture under local anesthesia. PCS produced sedation levels between eyelid closure with prompt response to verbal commands and drowsiness. Respiratory disturbance and hemodynamic change were not recognized. The patient was very cooperative, and felt comfortable during the operation. Propofol PCS is an appropriate method for a patient with respiratory dysfunction under local anesthesia.

Aged↗

[Leak test for the internal circuit of anesthesia machines].

In spite of detailed periodic inspection performed by specialized engineers, a great number of anesthesia machines fail to meet the standard of low flow leak test because of leak in the internal circuit. To find out the background and the solution to the problem, we sent questionnaire to 11 major manufacturers and/or dealers each responsible for periodic inspection of anesthetic machines. According to the responses to the questionnaire, the manufacturers and/or the dealers had various methods of internal circuit leak test without a unified standard in detail. The mismatch of the test methods with those anesthesia machines equipped with check valve mechanism has also led to poor evaluation of internal circuit leak. Leak test must be standardized for its appropriate application to work effectively for the problem of leak in the internal circuit of anesthesia machines.

Anesthesiology↗

[The current state of leak in anesthetic machines detected by low flow leak tests].

To assess the current state of leak in anesthetic machines, we selected 66 units of anesthetic machines for inspection and repair from various medical institutions. Based on a newly designed inspection flow chart a low flow leak test for internal circuits of the anesthetic machines was performed. The conventional low flow leak test was also performed for smooth detection of leak for rational evaluation. Only 39% of the anesthetic machines met the standard of the low flow leak tests, and leak was detected in the remaining 61%. The average residual leak mounted to 0.97 l.min-1, with the maximum of 5.3 l.min-1. Canisters, corrugated tubes, and vaporizers were considered the primary causes of leak. After the inspection and repair, leak in 77.5% of the anesthetic machines either disappeared or decreased and the average residual leak dropped to 0.34 l.min-1. However, 47% of the anesthetic machines still failed to meet the standard of the low flow leak tests. To further improve the situation, more detailed inspection and repair are necessary especially for precise detection of the cause of leak in the internal circuit of anesthetic machines which often remains undetected.

Anesthesiology↗

[Patient-controlled sedation using propofol for a patient with von Gierke disease].

Patient-controlled sedation (PCS) using propofol under spinal anesthesia in transurethral lithotripsy was carried out in a 44 year old patient with von Gierke disease accompanied with liver dysfunction, chronic renal failure, hypoglycemia and metabolic acidosis. After administering spinal anesthesia PCS was started (0.2 mg.kg-1 intravenous bolus dose of propofol; infusion at 2 mg.kg-1.h-1; a three-minute lockout time interval following an initial doses of 0.4 mg.kg-1). PCS with propofol, throughout the operation, brought about adequate sedation level for this patient with 2 or 3 on Wilson's sedation score, and the sedative effect by propofol diminished quickly within 15 minutes after the end of PCS. In addition, respiratory depression due to this sedation which would be worse in acidotic condition was not seen using PCS during the operation. This patient was much satisfied with this sedation in an interview during the postoperative period. PCS using propofol is a useful method without respiratory depression for a patient with von Gierke disease.

Adjuvants, Anesthesia↗

[Is patient-controlled sedation good for elderly patients?].

The purpose of this study was to evaluate the safety and advantage of intra-operative patient-controlled sedation (PCS) in elderly patients. Propofol PCS was compared with anesthesiologist-controlled sedation (ACS) during knee arthroplasty under epidural anesthesia. Eleven elderly patients scheduled for unilateral knee total or partial arthroplasty were divided randomly into PCS group (n = 6) and ACS group (n = 5). Epidural anesthesia was performed to produce an appropriate level of sensory block (T 10 through S). Firstly a mixture of pentazocine 0.2 mg.kg-1 and 2% mepivacaine 6-9 ml was injected to the epidural space, and anaesthesia was maintained using 2% mepivacaine afterward. Patients in both groups received propofol 0.3 mg.kg-1 i.v. as a loading dose and 0.6 mg.kg-1.h-1 continuous infusion. Furthermore patients in PCS group received propofol PCS (bolus: 0.2 mg.kg-1, lockout time: 3 min). Patients in ACS group were administered propofol continuously and infusion rates were regulated to maintain a sedation score 3 (Wilson et al) by anesthesiologist. Respiratory rate, blood pressure, heart rate, SpO2, arterial blood gas analysis and plasma levels of propofol were measured 4 times during and after the surgery. Satisfaction of patients and surgeons was questioned. Patients in PCS group received a mean propofol dose of 1.9 +/- 0.1 mg.kg-1 during procedures with a mean duration of 147 min. On the other hand patients in ACS group received propofol 2.9 +/- 0.3 mg.kg-1 with 142 min of procedures. Satisfaction of patients and surgeons, the incidence of complication were similar between the groups. For elderly patients who undergo epidural anesthesia, PCS is a safe and effective technique providing similar good sedation as with ACS.

Adjuvants, Anesthesia↗

[Where is a leak point detected by "the low flow leak test" of anesthetic machines?].

"The low flow leak test" is recommended for pre-anesthetic inspection of anesthetic machines. We carried out anesthesia compression tests as a standard. Even in that case, often the low flow leak test does not meet the standard. We investigated the point where there is a leak in the anesthetic machine. Observing the leak that fluctuates each time there is detachment or attachment of the canister, the primary cause of the leak is thought to be related to the canister. It is important to carry out an inspection of the canister if the low flow leak test does not meet the standard.

Anesthesiology↗

[Reduction of erythrocyte membrane band 4.2 protein in patients with obstructive jaundice].

Alteration of erythrocyte membrane proteins was studied in patients with obstructive jaundice in comparison with healthy controls. Analysis of the erythrocyte membrane proteins by SDS-PAGE revealed a slightly reduced protein 4.2 (MW 72 kDa). The erythrocytes with reduced protein 4.2 contained normal amounts of all other membrane proteins. In this study, it was demonstrated that the reduction of 4.2-protein is a common alteration in abnormal erythrocytes, target cells, and is observed in obstructive jaundice.

Adolescent↗