Long-term renal function of kidneys transplanted from non-heart-beating cadaver donors.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Torras.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Primary malignancies originating in large veins are infrequent. Leiomyosarcomas and malignant vascular tumors have been occasionally reported. The recently described histiocytoid hemangioma has a predilection for medium-sized and large vessels. A case is reported of histiocytoid hemangioma arising in the innominate vein and presenting clinically as a mediastinal mass.
Explore the source record for details and available documents.
Levels of antithrombin III (AT III) measured by two different methods, Factor V (FV) and One Stage Prothrombin Time, have been studied in two groups of patients: 55 with chronic liver disease and 22 with extra hepatic cholestasis. Results show a statistically significant correlation between the decrease of AT III and FV in the first group, and the normality of these parameters (unrelated to One Stage Prothrombin Time) in the second group. Levels at AT III and FV correlate directly with the functional integrity of hepatic parenchyma, so they may help in the differential diagnosis of different types of cholestasis.
Explore the source record for details and available documents.
Preformed xenoreactive natural antibodies (XNA) and complement mediate hyperacute xenograft rejection (HXR) in pig-to-human discordant xenotransplantation. In a pig kidney-human blood xenoperfusion model, we investigated whether XNA depletion and/or human complement inactivation preserved early pig kidney function. Pig kidneys were perfused for 180 min with pig blood (AUTO group, n = 8), human blood (HETER group, n = 6), complement-inactivated human blood (COMi group, n = 5), XNA-depleted human blood (ABd group, n = 5) or complement-inactivated and XNA-depleted human blood (ABd&COMi group, n = 5). HETER kidneys were rejected after 15-30 min and showed vascular microthrombi and interstitial hemorrhages. XNA depletion and/or complement inactivation prevented HXR. The glomerular filtration rate in ABd, COMi and ABd&COMi groups was significantly lower than in the AUTO group. Also, beyond 60 min, the COMi group showed a significantly lower glomerular filtration rate than that observed in ABd and ABd&COMi groups. Kidneys from ABd, COMi and ABd&COMi groups displayed endothelial cell edema, as well as higher soluble P-selectin levels and a higher renal myeloperoxidase content than the AUTO group kidneys. COMi and ABd&COMi groups had a significantly lower renal myeloperoxidase level than the HETER group. Also, in contrast to HETER and ABd groups, these complement-inactivated groups failed to show a positive correlation between P-selectin and renal myeloperoxidase. We also investigated platelet-activating factor (PAF) as possible mediator for these functional and pathologic changes. We found that blood PAF levels were similar in HETER, ABd, COMi and ABd&COMi groups and significantly higher than in the AUTO group. Also, when PAF was added to porcine endothelial cell monolayers, morphological changes due to cytoskeleton contraction were observed, and these changes were prevented by preincubation with a PAF receptor antagonist. In conclusion, although depletion of XNA and/or complement inactivation prevent HXR, the pig kidney function is not preserved at the level of the autologous combination. The PAF overproduction observed in the xenogenic combination, which is independent of the presence of XNA and complement, may be, at least in part, responsible for early endothelial cell morphological changes still present when HXR is prevented.
Explore the source record for details and available documents.
Venous pressure between the external jugular vein (EJV), and the superior caval vein (SCV) was compared in 15 patients, free of cardiorespiratory disease and undergoing abdominal surgery. In each patient data was taken in four different positions: A) anaesthetized patient in supine position and mechanical ventilation; B) anaesthetized patient in Trendelenburg position and mechanical ventilation; C) anaesthetized patient in anti-Trendelenburg and mechanical ventilation, and D) awake patient in supine position and spontaneous ventilation. A short, thick catheter with unique end lumen was used for EJV, and a long catheter from the basilic vein, to the SCV. Significant differences between mean and standard deviations of EJV and SCV were not founded. Linea correlation for the 4 positions was performed (r = 0.97, 0.91, 0.88 and 0.60 respectively) being significant for A-B y C positions. 4.5 cm H2O was the maximal difference obtained between SCV and EJV for A, B and C positions, and 10 cm H2O the maximal difference for the D position. The mean changes between the positions A-B, A-C and A-D was compared and significant differences (p less than or equal to 0.001) for A-C were seen, whereas A-B did not attain significant differences. We conclude that the EJV cannulation, with a short and thick catheter, allow the central venous pressure control during anaesthesia, in supine position, Trendelenburg and anti-Trendelenburg, but not during the recovery.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.