PubMed Health⌕ Search

Biomedical subjects

J V Linden

Publications and source records attributed to J V Linden.

At least 19 recordsLinked to original sources

Risk factors for infection with HBV and HCV in a largecohort of hemophiliac males.

BACKGROUND: Before the implementation of donor screening and the development of effective virus-inactivation procedures, persons with hemophilia (PWHs) were at risk of infection with HBV and HCV transmitted through clotting factor concentrates. STUDY DESIGN AND METHODS: Data collected from the medical records of a cohort of 2,772 males with hemophilia who resided in six states of the United States were used to examine relations between demographic and clinical characteristics and laboratory markers of past or present infection with HBV and HCV using logistic regression. RESULTS: Test results were available for 60 percent of the cohort. Among those tested, 30 percent were positive for markers of HBV infection and 64 percent for HCV infection. Factors associated with increased odds of positive HBV markers and HCV infection were greater severity of hemophilia, larger amounts of factor use, and HIV infection. Markers of HBV infection persisted in birth cohorts as late as 1992 and those of HCV infections in birth cohorts through 1991. Compared to same-age US males, PWHs born between 1987 and 1989 were more likely to have markers of HBV and HCV infection. CONCLUSION: PWHs who received clotting factor concentrates before 1990 may be at risk for infection with hepatitis B or hepatitis C and should be tested.

Acquired Immunodeficiency Syndrome↗

Transfusion-associated transmission of babesiosis in New York State.

BACKGROUND: Babesiosis can be life-threatening in immunocompromised individuals. Although the disease is usually transmitted by tick bite, more than 20 cases have been reported of infection transmitted by transfusion of blood or blood components obtained from apparently healthy donors from endemic areas in the United States. This report describes several recent cases of transfusion-transmitted babesiosis in New York State. STUDY DESIGN AND METHODS: Transfusion-associated incidents of babesiosis infection were identified and investigated. Seroprevalence of babesiosis in healthy blood donors in a highly endemic area was ascertained. RESULTS: In three incidents, babesiosis was diagnosed in five of eight patients given infected blood: two premature infants, an elderly patient with gastrointestinal bleeding, and two patients with thalassemia. Seroprevalence in blood donors on Shelter Island (Suffolk County, eastern Long Island), a highly endemic area, was 4.3 percent in May 1998. CONCLUSIONS: Infected donors lived in endemic areas and were asymptomatic with no history of tick bite. Blood collected in January 1997 from one donor was infectious. Those transfusion recipients who were infected were neonatal, elderly, or chronically transfused patients. Babesiosis should be included in the differential diagnosis of febrile illness in immunocompromised recipients of blood transfusion, particularly in the Northeastern United States.

Adult↗

The release of unsuitable units through misinterpretation of laboratory results transmitted by facsimile.

BACKGROUND: Preventable errors in transfusion medicine that have a significant risk of adverse outcome include the erroneous administration of blood of the wrong type or blood with unsuitable laboratory test results. Mandatory reports of errors by facilities providing blood services in New York State offer the opportunity for review and analysis of common factors. The state also collects statistics on the collection, laboratory testing, distribution, and disposition of blood in these facilities. CASE REPORTS: Three serious errors in transfusion medicine occurred within 3 months as a result of the misinterpretation of laboratory test results transmitted by facsimile. Two unsuitable units of blood were erroneously released, and a unit mislabeled as to the ABO group was incorporated into the hospital inventory. One of the unsuitable units was repeatedly reactive for HIV (although negative on confirmatory testing), and the other was confirmed positive for HCV. CONCLUSIONS: The vast majority of blood collected in New York State is tested by reference laboratories. Results are often transmitted by facsimile. Facsimile results may be misinterpreted because of distortion during transmission, misreading, or failure to note a separate report of pending results. Such misinterpretation results in an increased risk of adverse outcome for transfusion recipients. Laboratory results to be transmitted by facsimile could readily-and should-be clarified.

Humans↗

Transfusion errors in New York State: an analysis of 10 years' experience.

BACKGROUND: While public focus is on the risk of infectious disease from the blood supply, transfusion errors also contribute significantly to adverse outcomes. This study characterizes such errors. STUDY DESIGN AND METHODS: The New York State Department of Health mandates the reporting of transfusion errors by the approximately 256 transfusion services licensed to operate in the state. Each incident from 1990 through 1998 that resulted in administration of blood to other than the intended patient or the issuance of blood of incorrect ABO or Rh group for transfusion was analyzed. RESULTS: Erroneous administration was observed for 1 of 19, 000 RBC units administered. Half of these events occurred outside the blood bank (administration to the wrong recipient, 38%; phlebotomy errors, 13%). Isolated blood bank errors, including testing of the wrong specimen, transcription errors, and issuance of the wrong unit, were responsible for 29 percent of events. Many events (15%) involved multiple errors; the most common was failure to detect at the bedside that an incorrect unit had been issued. CONCLUSION: Transfusion error continues to be a significant risk. Most errors result from human actions and thus may be preventable. The majority of events occur outside the blood bank, which suggests that hospitalwide efforts at prevention may be required.

ABO Blood-Group System↗

An overview of state efforts to improve transfusion medicine. The New York state model.

OBJECTIVE: New York State must provide effective oversight for more than 400 facilities that provide blood services, ensuring the safety of transfusion recipients. PROGRAM STRUCTURE: Oversight is based on educated, trained program staff; a council of transfusion medicine experts; regulations governing laboratories and blood banking services; proficiency testing; requirements for reporting transfusion-related errors and incidents; tracking collection, testing, and disposition of all blood; inspections; partnership with the Food and Drug Administration; and investigation of incident reports. Policy letters and guidelines (eg, umbilical cord blood, transfusion-associated infections, intraoperative blood recovery) supplement regulations. OBSERVATIONS: Standards are maintained through education by a responsive, proactive oversight program. Areas warranting stricter regulation or supplemental educational guidelines are identified by periodic assessment of standards of practice and review of reported information. CONCLUSION: The multifaceted oversight program contributes to efforts to improve transfusion medicine.

Blood Banks↗

Errors in transfusion medicine. Scope of the problem.

Error is ubiquitous whenever humans are involved in a process. Fortunately, most transfusion-related errors are benign. However, the risk of death due to acute hemolytic transfusion reaction rivals that of human immunodeficiency virus transmission and administration of the wrong blood or of blood to the wrong recipient has occurred at many facilities. Most blood misadministration errors are caused by failure to identify the recipient and blood unit adequately, although phlebotomy errors and blood bank errors also contribute. Many errors are multifactorial and may reflect underlying systems defects. Noncompliant specimen labels may be a cue to an increased risk of phlebotomy error. Autologous blood is not immune from error and poses infectious disease risks as well as the risk of hemolytic transfusion reaction; also, perioperatively recovered blood may pose a risk of air embolism if improperly handled.

Blood Specimen Collection↗

New York State guidelines for cord blood banking. Department of Health.

In response to the profound interest in the transplantation of umbilical cord blood, the New York State (NYS) Department of Health embarked on a regulatory strategy designed to provide guidance to the practitioner while allowing for the flexibility required by the inherent developmental nature of the technology. The result was the development of the Guidelines for Collection, Processing, and Storage of Cord Blood Stem Cells, adherence to which is optional. It is anticipated that through the use of such guidelines as a supplement to the existing hematopoietic progenitor cell (HPC) regulations for tissue banks, practitioners may provide to potential patients the safest and most efficacious cord blood products currently available, and information gained through the use of these products will be of optimal value toward the goal of continuous improvement in the delivery of this new technology.

Blood Banks↗

Fatal air embolism due to perioperative blood recovery.

This study was initiated to investigate the incidence of acute mortality from air embolism associated with perioperative blood recovery and the causative factors and common characteristics of such fatalities. All facilities providing transfusion services in New York State are required to report severe adverse reactions to, and the total number of, transfusion and blood recovery procedures performed. Relevant data for the period from January 1990 to June 1995 were tabulated. During this time, 127,586 perioperative blood recovery procedures were performed, and 8,955,619 conventional blood components were transfused. The frequency of fatal air embolism after readministration of recovered blood was approximately 1:30,000-1:38,000; none followed conventional transfusion. Characteristics common to the fatalities (including an additional case reported before the study interval) were examined; all involved reinfusion of recovered blood under pressure. In the population studied, the incidence of fatal air embolism after the perioperative readministration of recovered blood was significantly higher than that after conventional transfusion. A model of such a system demonstrated that as much as 200 mL of air could enter the circulation in as little as 4 s, rendering visual detection and intervention extremely difficult. Education and guidelines to reduce the risk and mortality associated with this procedure are recommended.

Adult↗

Data on apheresis, blood collection, and transfusion-related activities: statistical analyses of the American Association of Blood Banks institutional membership questionnaires.

BACKGROUND: The American Association of Blood Banks annually surveys institutional members on activities pertinent to blood collections, apheresis, and transfusions. STUDY DESIGN AND METHODS: Retrospective descriptive statistics and comparative statistical analyses including trend tests were performed on selected topics from the 1989, 1990, and 1991 Institutional Questionnaires. The data were compiled by institution type, namely, regional and community blood donor collection centers and hospital-based facilities. Evaluated topics included the apheresis and therapeutic procedures performed, transfusion-associated AIDS and hepatitis, and the blood components (red cells, platelets, fresh-frozen plasma, and cryoprecipitate) that were collected, transfused, or outdated or discarded. RESULTS: Significant findings (p<0.05) included upward trends over time in the numbers of donor plateletpheresis units collected and transfused and in the numbers of random-donor platelet concentrates collected by hospitals. There was an upward trend over time in the outdating or discarding of all blood component types that was reported by hospitals. Data from blood centers showed the outdating or discarding of significant numbers of apheresis platelets, fresh-frozen plasma, and cryoprecipitate. No significant trends were identified in the reported cases of transfusion-associated hepatitis or AIDS. CONCLUSION: Ongoing data analysis of the institutional questionnaires provides information on trends in blood collection and transfusion-related activities.

Blood Banks↗

Blood donor-, apheresis-, and transfusion-related activities: results of the 1991 American Association of Blood Banks Institutional Membership Questionnaire.

Approximately 2154 regional blood centers and hospital-based blood banks and transfusion services responded to the 1991 American Association of Blood Banks Institutional Membership Questionnaire that elicited data from 1990. Information from 2144 institutions was considered valid. Questionnaire topics were donor blood collections, hemapheresis, perioperative cell salvage, component usage, and transfusion-associated diseases. Institutional members reported collecting 9.3 million units, of which 90.9 percent were for allogeneic use in the community, 6.0 percent were for autologous use, and 3.1 percent were directed donations. The percentage of directed-donor units that were crossed over for allogeneic use (51%) was greater than the percentage of units transfused to the designated patient (49%). Only 12.5 percent of institutions reported obtaining specific consent for transfusion. Of the 15.4 million transfused blood components, 8.5 million were red cells, 4.1 million were platelets, 1.8 million were fresh-frozen plasma, and 0.9 million were cryoprecipitate. There were 1263 reported cases of transfusion-associated hepatitis. Approximately 44 percent of the patients who were tested proved positive for hepatitis B surface antigen, and 80 percent of the patients who were tested proved positive for antibody to hepatitis C. The questionnaire's aggregate results can be used to assess current patterns of blood donation and transfusion activities.

Acquired Immunodeficiency Syndrome↗

Mandating vitamin K prophylaxis for newborns in New York State.

New York State's infant deaths and hospitalizations attributed to hemorrhagic disease of the newborn and other neonatal hemorrhagic conditions were reviewed. In 65% of 34 deaths reviewed, vitamin K was not documented as given or was given only after the onset of hemorrhage. Vitamin K was not included in standing orders in any of 22 hospitals contacted. As a result of this review, vitamin K prophylaxis was made a mandatory newborn care procedure in the State Public Health Code.

Cerebral Hemorrhage↗

A report of 104 transfusion errors in New York State.

In New York State, significant incidents involving the collection, processing, or transfusion of blood must be reported. Incident reports received over a 22-month period involving transfusion of blood to other than the intended recipient or release of blood of an incorrect group were analyzed. Among 1,784,600 transfusions of red cell components; there were 92 cases of erroneous transfusion that met study criteria (1/19,000). There were 54 ABO-incompatible transfusions (1/33,000); three of these (1/600,000) were fatal. Correction for underreporting of ABO-compatible errors resulted in an estimate of 1 per 12,000 as the true risk of transfusion error. National application of New York State data results in an estimate of 800 to 900 projected red cell-associated errors in the United States annually. The majority of reported errors occurred outside of the blood bank (43% resulted solely from failure to identify the patient and/or unit prior to transfusion and 11% resulted from phlebotomist error), while the blood bank was responsible for 25 percent of errors and contributed, with another hospital service, to 17 percent. The risk of transfusion of ABO-incompatible blood remains significant, and additional precautions to minimize the likelihood of such events should be considered.

ABO Blood-Group System↗