Cultivation of keratinocytes on poly HEMA and their migration after inversion.

This study demonstrates how the pretreatment of poly HEMA disks with bovine serum influences the adhesion of human keratinocytes in vitro. The ability of these cells to migrate from poly HEMA disks to a polystyrene petri dish surface colonized with irradiated 3T3 cells is also evaluated. The stimulatory effect of 24-h preincubation of the poly HEMA disks with bovine serum on the keratinocyte adhesion and growth was dependent on the concentration of the serum used. The keratinocytes migrated from the poly HEMA disks to polystyrene colonized with irradiated 3T3 cells. The numerous cells which migrated from the poly HEMA were positive for cytokeratin 10 (suprabasal layers) after 3 weeks and for cytokeratin 1 (cornified layer) after 1 month. These results seem to be encouraging for further experiments with respect to clinical application.

Animals↗

Toxicity of monomers HEMA, DEGMA and AEMA, used in synthesis of hydrogels for medical applications.

Acute toxicity parameters (lethal doses) were evaluated and calculated after i.m. and i.p. administration of 2-hydroxyethyl methacrylate (HEMA), 2-(hydroxyethoxy)ethyl methacrylate (DEGMA) and 2-(acetoxy)ethyl methacrylate (AEMA) to rats. Our previous findings were revisited and corrected. Based on preceding standardization and physiological values study, some clinical chemical and hematological markers of in vivo subacute i.m. toxicity were followed. Hematological parameters revealed to be of low sensitivity to the toxic influence. Clinical chemical tests suggest the prevalent muscle cell injury.

Animals↗

[Distribution of 3H-labeled acetyl-HEMA monomer in rats].

Original method of tritiation of acetyl-HEMA and its hydrogenated product was developed. Distribution and excretion of both compounds was examined in rat for up to 70 hrs. While the distribution in the tissues examined (liver, spleen, kidney, lung, muscle, heart, and skin) was nearly uniform, the excretion of acetyl-HEMA and its hydrogenated form differed: acetyl-HEMA in the 24. hour is excreted preferably into urine, the hydrogenated form in faeces. In addition to it the later form was absorbed from the application point (muscle) more rapidly. Distinct cumulation of activity (original compound or/and its metabolites) was observed in all tissues.

Acetylation↗

Mapping of endogenous lectins in macrophages colonizing an implanted polymer surface--effect of polymer structure.

The design of synthetic polymers may affect structural features of inflammatory cells, for example the expression of endogenous sugar receptor molecules like lectins in macrophages and foreign body giant multinucleate cells. This characteristic was studied histochemically by use of biotinylated (neo)glycoproteins. The results demonstrate the influence of polymer structure on the phenotypic expression of molecules recognizing carbohydrates in these cells. Very strong activity was observed for carrier-immobilized beta-galactose in cells colonizing hydrophobic polystyrene implants. Sialic acid moieties were not recognized by cells located on the surface of all types of polymeric implant. This study encourages investigation of the influence of polymer design on the differentiation of macrophages.

Animals↗

[Use of highly hydrated contact lenses for therapeutic purposes].

The paper deals with the therapeutic use of contact lenses made from a new highly hydrated material developed in the Institute of Macromolecular Chemistry in Prague. Contact lenses made from a meshed copolymer of n-vinyl pyrrolidone with acetoxyethyl meta-acrylate were applied to a group of 83 patients--a total of 87 eyes. A favourable therapeutic effect was achieved in all groups of patients--in simple traumatic erosions, superficial keratopathies, relapsing erosions, bullous keratopathies, corrosion of cornea, for mechanical protection of epithelization and in persisting ulcerations. In 71 eyes (82%) the contact lens was removed after the therapeutic effect was achieved, in 4 (5%) treatment still proceeds. In the remaining patients treatment was discontinued on account of complications, persistence of the pathological finding and frequent losses of contact lenses. In the group there was no case of complicating keratoconjunctivitis. Progressing vascularization was detected in three cases in the group with persisting ulcerations. The authors did not observe development of corneal vascularization in conjunction with application of the lens. Transient corneal oedema was revealed in the group of relapsing erosions in 6 (40%) patients and in the group of persisting superficial keratopathies in 4 (31%). The rare occurrence of inflammatory complications can be explained by the sterile application of contact lenses for the necessary length of time, the local administration of antibiotics while the defect persisted and frequent check-up examinations. Contact lenses made from the described material proved useful for therapeutic application.

Contact Lenses, Hydrophilic↗

Simulated quantitative and qualitative isotachophoretic indices of 73 amino acids and peptides in the pH range 6.4-10.

Qualitative and quantitative isotachophoretic indices of 73 amino acids, dipeptides and tripeptides were simulated under 24 leading electrolyte conditions covering the pH range 6.4-10. The RE values and time-based zone lengths are tabulated together with the absolute mobility (m0) and pKa values used. The leading electrolyte used was 10 mM HCl and the pH buffers were imidazole, tris(hydroxymethylamino)methane, 2-amino-2-methyl-1,3-propanediol and ethanolamine. The simulated indices will be useful in the assessment of the separability and determination of the listed and related compounds.

Amino Acid Sequence↗

Determination of limiting ionic mobilities and dissociation constants of some local anaesthetics.

The limiting ionic mobilities and thermodynamic acid dissociation constants were calculated from isotachophoretic experiments for the local anaesthetics procaine, tetracaine, lidocaine, trimecaine, bupivacaine, cinchocaine, diperodone, diocaine, cocaine, psicaine-neu, tropacocaine, amylocaine, beta-eucaine and leucinocaine. The pH values at which the local anaesthetics with very similar limiting ionic mobilities can be isotachophoretically separated were determined from simulated mobility curves. The measuring apparatus employed a high-frequency contactless conductivity detector.

Anesthetics, Local↗

The surface treatment of polypropylene molds and its effect on the quality of cast contact lenses.

An investigation of the surface by XPS photoelectron spectroscopy has shown that the process of production of cast contact lenses based on poly(2-hydroxyethyl methacrylate-co-diethyleneglycol methacrylate) is accompanied by mass transfer at the lens-mold boundary. This phenomenon, which impairs the compatibility of the lens during its application, can be considerably suppressed by employing a suitable surface modification of polypropylene molds. The surface treatment consisting in the oxidation of the mold surface by an AC corona discharge in the oxygen atmosphere increases hydrophilicity of the material, thus facilitating separation of the lens from the mold. The results of the XPS study were also confirmed microscopically by employing the SEM method.

Contact Lenses, Hydrophilic↗

Histochemical changes in the rabbit cornea and plasmin activity in the tear fluid during contact lens wear. Favourable influence of protease inhibitors (aprotinin, PC5, elastatinal).

Plasmin activity in the tear fluid of the rabbit eye was examined during the wearing of soft contact lenses (SCL) and compared with the occurrence of corneal disturbances assessed in cryostat sections. Plasmin activity was determined with a semiquantitative method using dry punches of filter paper previously soaked in 0.1 M Tris-HCl buffer solution containing mmol/l D-Val-Leu-Lys-FCA (trifluoromethylaminocoumarine), pH 7.2. Punches were applied to the corneal surface for 5 s (tear collection) and incubated in wet chamber. The time of appearance of the bright yellow fluorescence in UV light was recorded and taken as a measure of plasmin activity. For calibration punches soaked in solutions containing plasmin in various concentrations, and processed in the same manner were used. Changes in the cornea were examined histochemically using methods of choice for acid glycosidases, proteases, dehydrogenases, and Na(+)-K(+)-ATPase. SCL with high and low water content were worn in rabbits in 1, 2, 4, 7, 14, 21 and 28 days. Decreased activity of Na(+)-K(+)-ATPase, GGT, and SDH in the corneal endothelium and epithelium were not accompanied by detectable plasmin activity in the tear fluid. Pronounced damage of the corneal epithelium (increased activities of acid glycosidases, acid proteases, LDH, markedly decreased activity of SDH) was accompanied by low concentration of plasmin (0.4-1.0 micrograms/ml) in the tear fluid. Middle activity of plasmin (1.0-2.0 micrograms/ml) was detectable when PMNs were present in the corneal stroma. High plasmin activity (2.0-3.0 micrograms/ml) correlated with corneal ulceration and vascularization.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

[The first stage of clinical trials of hydrogel lenses manufactured in Czechoslovakia].

The authors give an account of the results of the first stage of clinical trials of Czechoslovak disc-shaped hydrogel lenses made from the copolymer HEMA and methacrylic acid. Hitherto assembled experience provided evidence that the envelope technique for opening of the anterior capsule does not ensure sufficient stability of these lenses in the later stage and their decentration may cause serious complications. Therefore the optimal solution is to place the implant in the capsule after circular capsulorhexy. Improvement of the geometrical and optic properties of the lenses during the subsequent follow-up and their perfect harmony with the surgical technique will produce even better functional results in operated patients.

Aged↗

Accumulation of boron-10 (10B) in cell cultures exposed to mercaptododecaborate (Na2H(11)10B12SH) used for the neutron capture therapy of brain tumors.

Toxicity of mercaptoundecahydro-closo-dodecaborate (MHB, Na2H(11)10B12SH) and accumulation of MHB-derived 10B were studied in E7 neuroblastoma, C6 glioma, HeLa cells and embryonic lung LEP 19 fibroblasts in culture in exponential and stationary phases of growth (2- and 7-day-old cultures, respectively). The pilot study of acute toxicity, performed on C6 glioma cells, showed good tolerance of the drug up to 1000 micrograms/ml (4.8 x 10(-3) M), when cell growth slowed and a small part of the population was lethally damaged (8.3%, 20-h incubation interval). The changes became more extensive and appeared sooner (toward 5 h) at 2000 micrograms MHB/ml (9.5 x 10(-3) M). None of the four cell lines used was found to be affected in gross morphology or growth by 200 micrograms MHB/ml within a 5-day culture interval. When exposed to this dose for 4 h, the amount of 10B accumulated in cell lines at the exponential growth phase ranged from 0.51 to 4.4 ng/micrograms protein; in the stationary cultures of the corresponding cell phenotype, the 10B values were 3 to 10 times lower (0.12-1.2 ng/micrograms protein). Irrespective of the growth phase, the values achieved in C6 glioma cells were several times higher than in the other cell lines. Furthermore, in the glioma cells, particularly in the exponential phase of growth, accumulation of 10B proceeded against the marked concentration gradient. The data provide a new indication for the use of MHB for boron neutron capture therapy of brain tumors.

Animals↗

The influence of hydrogel functional groups on cell behavior.

This study provides information on the behavior of macrophages on the surface of the subcutaneously implanted hydrogel strips. Hydrogel containing -OH, -CO-NH-, and (CH3)2N- groups induced a spreading of macrophages on the implants. The materials containing -SO3H groups slightly, and materials containing -COOH groups more intensively, inhibited spreading of the macrophages. The fusion of macrophages into multinucleate cells was inhibited on the surface of materials containing acidic groups (-SO3H, -COOH) and increased on the hydrogels containing 30 mol% of alkaline (CH3)2N- groups in comparison with hydrogels containing -OH or -CO -NH- groups. The differences of the behavior of macrophages on the surface of individual types of hydrogels are probably independent on the adsorption of plasma fibronectin onto the hydrogels. The correlation between the macrophages spreading and fusion and surface charge of the hydrogel implant can be hypothetically explained by electrostatic interaction between macrophages cell membrane and implant.

Animals↗

Silicone rubber-hydrogel composites as polymeric biomaterials. II. Hydrophilicity and permeability to water-soluble low-molecular-weight compounds.

The surface and transport properties of water-swollen silicone rubber-hydrogel composites were investigated. Surface wettability of these materials, composed of a polysiloxane matrix and the hydrogel phase consisting of very fine particles of lightly cross-linked poly(2-hydroxyethylmethacrylate), increased markedly with increasing content of the hydrogel phase. For composite materials containing a lightly cross-linked 2-hydroxyethylmethacrylate (HEMA)-methacrylic acid (MAA) copolymer and polymethacrylic acid (PMAA) as the hydrogel phase, permeability to water-soluble organic compounds and drugs were measured. The permeability varied within a broad range depending on the composition and content of the hydrogel phase. High permeation rates could be obtained while still retaining relatively fair mechanical properties. Relationships between the composition of silicone rubber-hydrogel composites, their structure and the permeation coefficients of the individual permeates are discussed.

Biocompatible Materials↗

[Use of a new type of hydrogel in bone surgery].

The authors submit information on the properties of a new macroporous hydrogel, which was synthetized specially for use in bone surgery. In animal experiments the authors evaluate microscopically the biocompatibility and process of biodegradation of the implant in osseous tissue.

Animals↗

[Comparison of tolerance to hydrophilic contact lenses made of Hema (37% H2O) and Hema-Degma (55%, 65% H2O) in the rabbit eye. I. Changes in corneal transparency due to disturbed hydration].

The authors compared on the rabbit eye the tolerance of hydrophilic contact lenses with equal parameters (0.2 mm central and peripheral thickness, 7.4 radius, 15 mm diameter) with a different degree of hydration (37% H2O-Hema), (55% and 65% H2O-Hema-Degma) during continuous wear for a period of two weeks (1, 2, 3, 4, 7 and 14 days). Special attention was devoted to changes in the transparency of the cornea. Changes of the transparency due to wearing of contact lenses were due to changes of corneal hydration. The cause of increased corneal hydration were metabolic and later also morphological disorders in the corneal endothelium. The activity of Na+-K+-dependent adenosine triphosphatase and gamma-glutamyl transferase were reduced, followed by a change in the shape and size of endothelial cells. Later the activities of both enzymes were reduced also in the epithelium. Keratocytes had reduced alkaline phosphatase and gamma-glutamyl transferase activities. The staining properties of glycosaminoglycans in the stroma remained, however, unaltered, similarly as the activity of acid glycosidases and other investigated lysosomal enzymes. The onset of increased corneal hydration caused by a disorder of the active water ion transport and of metabolites in the cornea depended on the percentage of water in hydrophilic contact lenses. It was observed latest after application of contact lenses with 65% water.

Animals↗

[Comparison of tolerance to hydrophilic contact lenses made of Hema (37% H2O) and Hema-Degma (55%, 65% H2O) in the rabbit eye. II. Changes in corneal transparency due profound degenerative processes].

The authors investigated on the rabbit eye the effect of long-term continuous wearing (14, 21, 28 days) hydrophilic contact lenses (h. c. l.) with varying degrees of hydration (37%, 55%, 65% water). Long-term wearing of the lenses caused disorders in all corneal layers. These changes are identical in all types of contact lenses, only their onset is earlier and the extent is more marked in contact lenses with a low hydration (37% water). Contrary to epithelial changes in the corneal stroma, the changes are qualitatively different depending on the degree of hydration of the contact lens. Prolonged application of contact lenses with 37% water leads to infiltration of the stroma by inflammatory cells which carry the activities of destructive lysosomal enzymes. The latter are gradually released into tissues and local degenerative processes develop which in some instances culminate by ulceration. Other corneas are vascularized. The described changes in stroma were not found in hydrophilic contact lenses with 55% and 65% water. After prolonged application of highly hydrated contact lenses (65% water) the authors, however, observed uptake of liquid from the upper third of the stroma due to the contact lens which dried on the eye and acted on the cornea as a hypertonic solution. In this subepithelial zone the staining of glycosaminoglycans was reduced, similarly as the enzymatic activities in keratocytes which suggests serious degenerative processes, i. e. disorders in the synthesis of components of the ground substance of the corneal stroma.

Animals↗

[Clinico-pathologic evaluation of one type of intraocular lens].

Four intraocular lenses of Saturn type (extrapupillar iris lens fixated in the posterior chamber) were surgically removed when bullous pseudophakic keratopathy was present, without loss of the eye-bulb, during the period of 2-6.5 years after the performed implantation. Cytologic examination of the surface of the implanted lens displayed the individual tolerance of the implant in various patients. In all cases on the surface of the lenses there was observed a reactive membrane, also in the cases of the low biological tolerance.

Adult↗