PubMed Health⌕ Search

Biomedical subjects

J Vandenbogaerde

Publications and source records attributed to J Vandenbogaerde.

15 recordsLinked to original sources

Delayed restoration of atrial function after conversion of atrial flutter by pacing or electrical cardioversion.

It is often suggested but never proven that atrial function is not affected during atrial flutter, nor after its conversion to normal sinus rhythm. To evaluate this hypothesis, a prospective study was performed in 22 patients (age range 20 to 88 years) with atrial flutter. Diastolic transmitral flow was analyzed with echo-Doppler before and after conversion. After randomization, conversion was attempted with overdrive pacing or up to two 50 J shocks. If the initial method was unsuccessful, a 200 J shock was administered. All patients were converted to sinus rhythm with this protocol. Shortly after conversion (at 1 and 6 hours), atrial contribution to ventricular filling was absent in 4 of 22 patients. In the remaining 18 patients, atrial contribution to ventricular filling was small. Atrial contribution to transmitral flow improved from 20 to 27% within 24 hours (p < 0.01) and increased further to 38% at 6 weeks (p < 0.005). Peak velocity of late diastolic filling increased from 0.28 m/s after 1 hour to 0.39 m/s after 24 hours (p < 0.0001) and improved even further during later follow-up. In 1 patient, an effective atrial systole was not observed until the 14th day. Cardiac output did not change significantly during the study period. No differences were observed between the conversion modalities. In conclusion, atrial dysfunction is present immediately after conversion of atrial flutter to normal sinus rhythm. This dysfunction occurs also after overdrive pacing and can last > 1 week. The findings suggest that stasis in the atria can remain temporarily present after successful conversion of atrial flutter to sinus rhythm.

Adult↗

Computer-controlled in vitro model of the human left heart.

The decision for surgical intervention in the treatment of stenosis and for regurgitation of the mitral valve demands an objective and quantitative evaluation of the severity of mitral valve disease. The availability of ultrasound techniques capable of analysing flow velocities across valves and to produce representative images of valve orifices has increased the interest in the hydraulics of cardiac valves. To isolate and study the determinants of transmitral flow, an in vitro model of the human left heart was built. From the model it is possible to differentiate the influence of the different determinants of left heart performance on transmitral flow: preload, compliance of the left atrium and ventricle, peripheral resistance (afterload) and heart rate. The mechanical part of the model consists of a reservoir connected to an elastic closed circuit (Latex pulmonary veins, left atrium, left ventricle and aortic arch) with replaceable mitral and aortic valves. The electronic part of the model drives and controls the hydraulic part, allowing the independent regulation and monitoring of left atrial and left ventricular pressures p, volumes V and 'pV-loops' throughout the cardiac cycle at different cardiac rhythms. Left atrial filling pressure and aortic resistance are variable in a controlled fashion. Echo-Doppler study of the mitral valve and the transmitral valve flow is possible both from an atrial and a ventricular window in the model. This technical note describes the model.

Heart↗

Transoesophageal echo-Doppler in patients suspected of a cardiac source of peripheral emboli.

The initial results of a controlled and partly blinded study aimed at evaluating the accuracy of transoesophageal echo-Doppler in detecting cardiac sources of peripheral emboli are reported. A total of 120 consecutive patients suspected of acute embolic events were entered. After completion of all investigations, the patients were classified into three groups: patients who had definitely not suffered an embolic event (controls; n = 56); patients in whom the differentiation between local thrombosis, embolic event originating from a diseased infarct-related artery or embolic event from a cardiac source was not possible (questionable cases; n = 24) and patients in whom a cardiac source of a definite embolic event was highly suspected (cardiac emboli; n = 40). Isolated interatrial septum anomaly and mitral valve prolapse were as frequent in the control group as in the embolism group. Transoesophageal echo-Doppler had a sensitivity of 83% and a specificity of 86% in correctly assigning a patient to the cardiac embolism group or to the control group. The positive and negative predictive values were 80% and 87% respectively. It is concluded that transoesophageal echo-Doppler is highly sensitive but is also specific in demonstrating cardiac sources of peripheral emboli.

Adult↗

Transesophageal echocardiography: a simple method for monitoring the patency of ventriculoatrial shunts. Technical note.

A new method for evaluating the patency of a ventriculoatrial shunt is described, and early experience with it is reported. Transesophageal echocardiography can demonstrate a cerebrospinal fluid leak in the right atrium through the atrial tip of a shunting device. This capability was an incidental discovery, and since then the accuracy of the technique in evaluating the patency of a ventriculoatrial shunt has been prospectively studied in 20 observations of 16 patients. The method proved to be accurate in 90% to 100% of cases. It is concluded that transesophageal echocardiography offers a rapid and accurate assessment of ventriculoatrial shunt function, is well tolerated, and is easy to perform.

Adolescent↗

The initial clinical evaluation of a transesophageal system with pulsed Doppler, continuous wave Doppler, and color flow imaging based on an annular array technology.

The application of transesophageal echocardiography (TEE) offers access to a great deal of important clinical information regarding cardiovascular anatomy and physiology. Two applications which have not been reported and would appear to be of interest are continuous wave Doppler capabilities and the implementation of higher frequency transducers. A TEE system designed at the Institute of Biomedical Engineering in Trondheim, which is based on an annular array technology, offers these capabilities. We evaluated this instrument in the clinical setting in a series of 30 patients to test the probe function in terms of the tissue and flow imaging quality with a 7.5 MHz carrier frequency, and to report on the implementation of a continuous wave Doppler modality in a TEE probe. We found that the annular array method permitted the use of high frequency probes for tissue and flow imaging which resulted in excellent image resolution, and that shifting the carrier frequency of the transducer to a lower frequency permitted the optimization of the Doppler sensitivity. The continuous wave Doppler was used to measure abnormal blood flow velocities in excess of 5.0 m/s, and was particularly useful in the operating room as velocity measurements could be obtained without compromising the sterile field. The results of our evaluation indicate that high imaging frequencies and continuous wave Doppler can be applied by an annular array TEE transducer.

Adolescent↗

Acute cholinesterase inhibitor poisoning mimicking pulmonary oedema.

In patients poisoned with a cholinesterase inhibitor, the diagnosis may initially be missed especially when no history is available from the patient or his relatives. The predominant respiratory symptoms may suggest pulmonary oedema as illustrated by the two case reports presented here. A high degree of suspicion and a careful clinical examination are necessary to make the correct diagnosis, which eventually can be confirmed by measurement of red cell and serum cholinesterase activity.

Aged↗

Creatine determinations as an early marker for the diagnosis of acute myocardial infarction.

In the acute phase of acute myocardial infarction (3-8 h after onset of symptoms) an early transient increase in the creatine concentration of serum, saliva, and especially of urine can be observed. Due to the renal threshold, urine values give a much better discrimination between infarction patients and controls than do serum determination. In some patients secondary peaks of serum and urine creatine concentrations can be seen about 24-36 h after hospital admission. Intramuscular injections of 5.0 mL of a saline solution and muscular trauma interfere with the test, but with angina pectoris interference is absent or limited. Creatine leakage from myocardium is insufficient to explain the observed creatinuria in infarctions, and intact extra-cardiac tissues are believed to be involved in creatine release.

Adolescent↗

[Hemodynamic aspects of bicarbonate dialysis].

About the comparison of the acetate haemodialysis with the bicarbonate haemodialysis different and partly contradictory data are found in literature. In general the bicarbonate haemodialysis is regarded as that variant of therapy which has a less negative influence on the haemodynamics during the dialysis treatment. On 21 patients comparative examinations were performed with the two variants of therapy. The acute complications during the treatment were registered, the circulatory parameters blood pressure, pulse rate and cardiac output (1/min) were measured and the oxygen partial pressure was established. Comparing the two methods of therapy, no essential differences could be found. Patients with evident acetate incompatibility showed significantly more frequently clinical complications under the acetate dialysis. In the acetate dialysis the oxygen partial pressure clearly decreased which is to be discussed as cause for the circulatory instability in this therapeutic method.

Bicarbonates↗

Ventricular pacing via a Swan Ganz catheter: a new mode of pacemaker therapy.

Hemodynamic monitoring via a Swan Ganz catheter is often required with critically-ill patients. In the further course of the illness emergency temporary pacing might be necessary, most frequently for AV-conduction disturbances or sinus bradycardia. Insertion via the right internal jugular vein has been used in many cases. This raises the problem that one may find a second central vein, which can lead to serious problems and in any case may be a dangerous waste of time. Recently we had the opportunity to stimulate the right ventricle with a small pacing wire, brought into the ventricle via a Swan Ganz catheter especially designed for this purpose with an extra lumen ending in the right ventricle of the heart. In this account we describe our experience with the first ten patients to whom this method was applied.

Adult↗

Paraquat poisoning.

A fatal case of paraquat poisoning is described. Postmortem concentration of paraquat in different tissues reveals that treatment in this case could not prevent lethal tissue accumulation. Although accumulation was more pronounced in renal tissue, lung toxicity caused death. The formation of enormous fecaliths and the appearance of hypercalcemia are reported. Both were most likely connected with Füllers earth therapy. In spite of the fact that the exact nature of the equilibrium between plasma levels and tissue accumulation of paraquat (static or dynamic) is not understood, aggressive treatment must be recommended, even after the distribution phase and despite likely "fatal" plasma levels.

Adult↗