PubMed Health⌕ Search

Biomedical subjects

J Verdú-Andrés

Publications and source records attributed to J Verdú-Andrés.

6 recordsLinked to original sources

Chemiluminescent method for detection of eutrophication sources by estimation of organic amino nitrogen and ammonium in water.

An automatic method has been developed for the estimation of organic amino nitrogen (CH2-NH) and ammonium in water samples. We propose a continuous flow system in which nitrogen compounds react with hypochlorite reagent to produce chloramines. Subsequently, the mixture is mixed with luminol, generating a chemiluminescence signal. The signal emission at 425 nm, registered as a function of time, decreases as nitrogen concentration increases, due to the decrease on hypochlorite concentration. A large number of nitrogen compounds have been assayed and their sensitivities compared, in milligrams per liter nitrogen. The ammonium calibration graph, expressed as N, can be used for most of the assayed compounds. The linear interval was 0.24-4 mg L(-1) N, with the detection limit 0.07 mg L(-1) N. The chemiluminescence method was applied to the analysis of several kinds of real water samples, natural, lake, irrigation ditch, fountain, residual, and seawater in order to detect possible sources of eutrophication. The accuracy (% relative error) and precision were satisfactory, with mean values of 5 +/- 4 and 3 +/- 2, respectively. This procedure has been used to estimate nitrogen content in samples before and after Kjeldahl treatment. In the same samples, the N found for the untreated samples provided a good estimation of the N Kjeldahl. Sixty samples per hour can be analyzed, and the procedure can also be used for in situ monitoring.

Journal Article↗

An evaluation of solid phase microextraction for aliphatic amines using derivatization with 9-fluorenylmethyl chloroformate and liquid chromatography.

The reliability of SPME combined with a chemical reaction for the analysis of short-chain aliphatic amines by liquid chromatography has been investigated. Different options to couple SPME and derivatization have been tested and compared: (i) derivatization of the analytes in solution followed by the extraction of the derivatives, (ii) extraction of the analytes and subsequent derivatization by immersing the SPME fibre onto a solution of the reagent, and (iii) extraction/derivatization of the analytes using fibres previously coated with the reagent. Methylamine (MA), dimethylamine (DMA) and trimethylamine (TMA) have been selected as a model of primary, secondary and tertiary amines, respectively. The analytes have been derivatized with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC), and the fibre coating was Carbowax-templated resin (CW-TR). The employment of fibres coated with FMOC to extract and derivatize the analytes was the best option, as compared with the other approaches tested the sensitivity was considerably improved. On the basis of these studies, a new procedure for the determination of MA, DMA and TMA in water is presented. To demonstrate the utility of the proposed conditions data on linearity, accuracy, repeatability and sensitivity are given. Results of the determination of the amines in tap, river and waste water are also presented.

Amines↗

Strategies for the enantiomeric determination of amphetamine and related compounds by liquid chromatography.

This paper summarizes recent research on the stereospecific analysis of amphetamine, its analogs and metabolites, by liquid chromatography. The different methods proposed have been evaluated and compared in terms of resolution power, time of analysis, sensitivity, or potential for automation. Chiral derivatization, followed by separation of the diastereomers formed in achiral chromatographic systems, is still the method preferred for the analysis of amphetamines at trace levels, as derivatization also improves analyte detectability. This is the method of choice for the enantiomeric analysis of amphetamines at the low concentrations typically encountered in biological samples. In recent years, special attention has been devoted to the development of alternatives for the automation of the analytical process by integrating the derivatization step into the chromatographic scheme. A promising alternative is the employment of beta-cyclodextrins as chiral selectors, both immobilized on the stationary phase and added to the mobile phase. However, with a few exceptions, beta-cyclodextrins perform better for non-derivatized amphetamines. Therefore, the utility of these selectors in the analysis of biological samples is limited. The reliability of less-used chiral stationary phases (Pirkle type, cellulose based or protein based), as well as methods based on the mathematical treatment of the chromatographic signal, are also discussed.

Amphetamines↗

Analysis of enantiomers giving partially overlapped peaks by using different treatments of the chromatographic ultraviolet signals: quantification of pseudoephedrine enantiomers.

Different strategies for the quantification of partially coeluting optical isomers have been investigated. The methods tested are based on the use of different features as the analytical UV signals: peak heights, perpendicular drop areas, first and second derivatives of the chromatograms, peak areas obtained by deconvolution of the overlapped peaks with data fitting optimization, and a multivariate model (principal component regression, PCR). The amphetamine-derivative drug pseudoephedrine was selected as a model compound. For chromatography, LiChrospher 100 RP18 and a mobile-phase consisting of methanol and a solution of carboxymethyl-beta-cyclodextrin (the chiral selector) were used. The UV detector was set at 215 nm. The accuracy obtained with the tested methods at different degrees of overlapping and at different concentration ratios between enantiomers was evaluated. The results of this study demonstrated that the best option for quantification of partially overlapped UV peaks of enantiomers and to obtain the enatiomeric excess is the use of a PCR model using peak heights, perpendicular drop peak areas and deconvoluted peak areas as the original variables. The predictive ability of the proposed calibration model is of about 2-8 times better (depending on the overlapping degree) than that achieved with the other models tested.

Ephedrine↗

Sensitive determination of methylenedioxylated amphetamines by liquid chromatography.

Different strategies for the liquid chromatographic determination of methylenedioxylated amphetamines were evaluated: separation and detection of underivatized analytes by (i) UV or (ii) fluorescence, (iii) derivatization with 3,5-dinitrobenzoyl chloride followed by separation and UV detection of the derivatives formed and (iv) derivatization with 9-fluorenylmethyl chloroformate (FMOC) and subsequent separation and fluorimetric detection of the derivatives. The compounds tested were 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDE). On the basis of these studies, a new procedure for the chromatographic determination of MDA, MDMA and MDE is proposed, based on derivatization with FMOC. The described procedure allows the quantification of the tested compounds with adequate linearity, reproducibility and accuracy in the concentration interval 0.5-20.0 micrograms mL-1. The limits of detection were 0.01 microgram mL-1 for MDA and 0.025 microgram mL-1 for MDMA and MDE. The utility of the described assay was tested by determining methylenedioxylated amphetamines in plasma and urine.

3,4-Methylenedioxyamphetamine↗

Determination of aliphatic amines in water by liquid chromatography using solid-phase extraction cartridges for preconcentration and derivatization.

Bond Elut C18 solid-phase extraction cartridges were used for preconcentration and pre-column derivatization with 3,5-dinitrobenzoyl chloride (DNB) of aliphatic amines in water. Conditions for analyte preconcentration and derivatization (including the volume of sample, concentration of reagent, time of reaction and pH) were investigated, using ethylamine, isopropylamine and dimethylamine as model compounds. On the basis of these studies, a rapid and sensitive method for the determination of aliphatic amines in water is presented. The analytes are retained and purified on the cartridges and then derivatized and desorbed by drawing in succession the DNB solution and acetonitrile. The collected extracts are subsequently chromatographed in a Hypersil ODS C18 column using acetonitrile-water for elution. The DNB derivatives are monitored at 230 nm. The method provides satisfactory reproducibility and linearity within the 0.050-1.0 mg l(-1) concentration interval, the limits of detection being 2-5 microg l(-1). Analyte recoveries were in the 70-102% range, whereas the conversion yields compared with those observed for the solution derivatization were in the 79-107% range. The total analysis time (sample treatment plus chromatography) was about 15 min. The method was applied to the determination of ethylamine, isopropylamine and dimethylamine in tap and river waters.

Amines↗