J Veseth-Rogers

Publications and source records attributed to J Veseth-Rogers.

5 recordsLinked to original sources

Comparison of efficacy of automatic implantable cardioverter defibrillator in patients older and younger than 65 years of age.

PURPOSE: The efficacy of the automatic implantable cardioverter defibrillator (AICD) was compared in elderly patients and younger patients with life-threatening ventricular tachyarrhythmias. Clinical characteristics, surgical complications, and long-term survival rates were compared between the two age groups. PATIENTS AND METHODS: A retrospective study was conducted of 54 elderly patients (greater than 65 years) and 79 younger patients (less than 65 years) who had had AICDs implanted for recurrent symptomatic ventricular tachycardia and/or ventricular fibrillation. RESULTS: In 85% of elderly patients and 78% of younger patients, coronary artery disease was the underlying disease (NS). The mean left ventricular ejection fraction was 31.4 +/- 14.3% in the elderly patients and 35.7 +/- 17.6% in the younger patients (NS). Concomitant myocardial revascularization was performed in 37% of elderly patients and 29% of younger patients (NS); however, only 4% of elderly patients had concomitant left ventricular resection or cryoablation, compared with 15% of younger patients (p less than 0.001). Two patients in each age group died perioperatively (4% versus 3%, NS), and no significant difference in surgical morbidity or length of hospital stay following AICD implantation was noted between the age groups. In conjunction with AICD, elderly patients more commonly received antiarrhythmic drugs, with 54% of elderly patients taking amiodarone at the time of hospital discharge compared with 29% of the younger patients (p less than 0.008). In contrast, beta-blockers were more commonly used in younger patients (16% versus 2%, p less than 0.03). At a mean follow-up of 25 months, 11 (20%) elderly patients and 16 (20%) younger patients had died. Six deaths in elderly patients and five deaths in younger patients were classified as arrhythmic deaths (NS); however, only one younger patient and three elderly patients died suddenly (NS). Calculated survival curves demonstrated similar survival rates in the two age groups with approximately 90%, 87%, and 80% of the patients alive at 1, 2, and 3 years, respectively. Theoretic survival curves calculated from appropriate AICD shocks demonstrated significantly lower survival compared with actual survival. CONCLUSION: It is concluded that AICD is a very effective treatment for life-threatening ventricular tachyarrhythmias, and this benefit applies to elderly patients as well as younger patients.

Adolescent↗

A practical approach to teaching the automatic implantable cardioverter-defibrillator patient.

An implantable defibrillator is a surgically implanted device capable of continuously monitoring the patient's heart rhythm and automatically delivering a cardioverting or defibrillating shock to the heart. This article describes one approach to teaching the implanted defibrillator patient. Preoperative, postoperative, and discharge teaching goals and content are discussed. A case study illustrates the need for contact with the emergency medical system.

Arrhythmias, Cardiac↗

Long-term internal cardiac defibrillation threshold stability.

The automatic implantable cardioverter-defibrillator is tested intraoperatively with defibrillation trials to ensure effectiveness. It is unknown if the energy requirement for internal defibrillation remains stable and that once demonstrated effective, if the device will continue to be effective in terminating lethal ventricular arrhythmias. In this study, the defibrillation energy requirement was compared in 56 patients at the time of lead implantation to that obtained at the time of generator replacement. Mean time to generator replacement was 17. +/- 6.6 months. The defibrillation threshold was stable over that time (11.9 +/- 6.7 joules compared to 12.7 +/- 8.4 joules, NS). There was no relation between transmyocardial impedance and defibrillation threshold. In addition, no effect on defibrillation threshold was demonstrated by the use of various cardiac medications, concomitant surgery or the occurrence of clinical shocks during follow-up.

Electric Countershock↗

Complications of automatic implantable cardioverter defibrillators: radiographic, CT, and echocardiographic evaluation.

Automatic implantable cardioverter defibrillators (AICDs) were studied in three groups: (a) Serial radiographs were reviewed in 51 clinic patients. Twenty of 96 (21%) AICD patches distorted with time. (b) Thirty-six postoperative computed tomographic (CT) scans of asymptomatic patients revealed that pericardial fluid collections were frequent during the month after surgery but rare beyond that. Echocardiography was insensitive for these collections. CT also demonstrated dense fibrosis around some distorted patches, months after surgery. (c) Five other patients with pericardial infection had distorted patches, and the four studied with CT had fluid beneath their patches. (d) A case of constrictive pericarditis had distorted patches but was not diagnosed with CT. The authors conclude that distorted patches may indicate postoperative complications and that CT is the imaging modality of choice.

Arrhythmias, Cardiac↗