ECG variable cine: computer program for presentation of temporal changes in ECG variables over different number of ECG leads.

The analysis of exercise electrocardiogram (ECG) is based on the alteration of the measured variables in the detection of coronary artery disease (CAD). In its existing form the analysis of the exercise ECG is laborious and requires much time. The temporal analysis of the ECG variable and the comparison between different phases of the exercise test is difficult and time consuming, especially the simultaneous examination of the variables over several leads. In this article we present a computer program, ECG Variable Cine, for the visualization of the temporal changes of values of exercise ECG variables over the selected ECG lead system. The program includes the stationary 3-D presentation for the variables' alteration simultaneously in all selected leads over the time of exercise test. In addition, the program determines two parameters; the average value of the variable over the selected leads at every sample moment, and the chronotropic index, a parameter that indicates heart rate response to exercise. According to the results the average value of ST-segment deviation at the end of the exercise over the leads and chronotropic index are clinically more competent than the maximum value of ST-segment depression in the detection of CAD.

Electrocardiography↗

Detection of coronary artery disease using maximum value of ST/HR hysteresis over different number of leads.

We have studied the effect of the number and ordering of exercise electrocardiographic (ECG) leads when using the maximum value of the ST segment depression/heart rate (ST/HR) hysteresis over a different number of leads for the detection of coronary artery disease (CAD). The study population consisted of 127 patients with CAD and 220 patients with a low likelihood of the disease referred for an exercise test at Tampere University Hospital, Finland. The lead system used was the Mason-Likar modification of the standard 12-lead system, and exercise tests were performed on a bicycle ergometer. The number of leads was studied using lead sets consisting of first 2 leads, then 3 leads, and so on, up to all 12 leads. The criterion for the order of inclusion of the next lead in the new lead set was based on the maximized area under the receiver operating characteristic (ROC) curve for the new lead set. The importance of the number of leads was evaluated by means of three different approaches: ROC analysis; using a fixed partition criterion of 0.01 mV; and using a fixed specificity value of 80%. According to the results, the most powerful diagnostic capacity of an individual lead was in lead V5, and the most deficient diagnostic capacities were in leads aVL and V1. Using the maximum search procedure, it was possible to improve the diagnostic capacity of the ST/HR hysteresis by anything from 4 up to a maximum of 8 leads. After that it started to decrease rapidly. In conclusion, this study suggests that the diagnostic capacity of the ST/HR hysteresis could be improved by increasing the number of leads. However, the selection of leads is of major importance when using the maximum value of the ST/HR hysteresis over the leads in the detection of CAD.

Adult↗

Correct utilization of exercise electrocardiographic leads in differentiation of men with coronary artery disease from patients with a low likelihood of coronary artery disease using peak exercise ST-segment depression.

In this study we compared the diagnostic characteristics of the individual exercise electrocardiographic leads, 3 different lead sets comprising standard leads and the effect of the partition value in the detection of coronary artery disease (CAD). The diagnostic variable used was ST-segment depression at peak exercise, and the study population consisted of 101 patients with CAD and 100 patients with a low likelihood of the disease. The lead system used was the Mason-Likar modification of the standard 12-lead system and exercise tests were performed on a bicycle ergometer. The comparisons were performed by means of receiver-operating characteristic analysis and by determining sensitivities at a fixed 95% specificity. These properties, defined here as diagnostic capacity, were the most efficacious in leads I, -aVR, V4, V5, and V6. Diagnostic capacities in leads aVL, aVF, III, V1, and V2 were quite poor; statistical comparisons indicated significant differences between these leads and lead V5 (p < or = 0.0001 in each case). Use of the maximum value of ST-segment depression at peak exercise derived from all 12 leads produced a considerable decrease in the diagnostic capacity of the exercise electrocardiogram compared with lead V5. The exclusion of leads aVL, V1, and III improved the diagnostic capacity compared with the 12-lead set, but it was still smaller than that of lead V5. With use of a lead set with the 5 best leads increased the diagnostic capacity over other lead sets and over any individual lead. Further improvement was noted when a 50% smaller partition value was applied to leads I and -aVR than for the other leads (p = 0.041). In conclusion, this study suggests that use of leads I, -aVR, V4, V5, and V6 is the most influential when differentiating between patients with CAD and patients with a low likelihood of disease using peak exercise ST-segment depression. The effective use of leads I and -aVR requires the partition value applied for these leads to be 50% smaller than that used for the lateral precordial leads.

Coronary Disease↗

Reproducibility of the ST-segment depression/heart rate analysis of the exercise electrocardiographic test in asymptomatic middle-aged population.

The reproducibility of the ST-segment depression against heart rate (ST/HR) hysteresis, ST/HR index, and end-exercise ST depression between the repeated exercise electrocardiographic tests were determined in 61 asymptomatic middle-aged subjects. The findings support the clinical utility of the ST/HR hysteresis, but it is noteworthy that the results also suggest that the magnitude of change in the exercise electrocardiographic variables, which has to be observed to make the clinician confident that a real diagnostic change has occurred, is surprisingly large.

Electrocardiography↗

The effect of lead selection on traditional and heart rate-adjusted ST segment analysis in the detection of coronary artery disease during exercise testing.

Several methods of heart rate-adjusted ST segment (ST/HR) analysis have been suggested to improve the diagnostic accuracy of exercise electrocardiography in the identification of coronary artery disease compared with traditional ST segment analysis. However, no comprehensive comparison of these methods on a lead-by-lead basis in all 12 electrocardiographic leads has been reported. This article compares the diagnostic performances of ST/HR hysteresis, ST/HR index, ST segment depression 3 minutes after recovery from exercise, and ST segment depression at peak exercise in a study population of 128 patients with angiographically proved coronary artery disease and 189 patients with a low likelihood of the disease. The methods were determined in each lead of the Mason-Likar modification of the standard 12-lead exercise electrocardiogram for each patient. The ST/HR hysteresis, ST/HR index, ST segment depression 3 minutes after recovery from exercise, and ST segment depression at peak exercise achieved more than 85% area under the receiver-operating characteristic curve in nine, none, three, and one of the 12 standard leads, respectively. The diagnostic performance of ST/HR hysteresis was significantly superior in each lead, with the exception of leads a VL and V1. Examination of individual leads in each study method revealed the high diagnostic performance of leads I and -aVR, indicating that the importance of these leads has been undervalued. In conclusion, the results indicate that when traditional ST segment analysis is used for the detection of coronary artery disease, more attention should be paid to the leads chosen for analysis, and lead-specific cut points should be applied. On the other hand, ST/HR hysteresis, which integrates the ST/HR depression of the exercise and recovery phases, seems to be relatively insensitive to the lead selection and significantly increases the diagnostic performance of exercise electrocardiography in the detection of coronary artery disease.

Coronary Disease↗

Computer model analysis of the relationship of ST-segment and ST-segment/heart rate slope response to the constituents of the ischemic injury source.

The objective of the study was to investigate a proposed linear relationship between the extent of myocardial ischemic injury and the ST-segment/heart rate (ST/HR) slope by computer simulation of the injury sources arising in exercise electrocardiographic (ECG) tests. The extent and location of the ischemic injury were simulated for both single- and multivessel coronary artery disease by use of an accurate source-volume conductor model which assumes a linear relationship between heart rate and extent of ischemia. The results indicated that in some cases the ST/HR slope in leads II, aVF, and especially V5 may be related to the extent of ischemia. However, the simulations demonstrated that neither the ST-segment deviation nor the ST/HR slope was directly proportional to either the area of the ischemic boundary or the number of vessels occluded. Furthermore, in multivessel coronary artery disease, the temporal and spatial diversity of the generated multiple injury sources distorted the presumed linearity between ST-segment deviation and heart rate. It was concluded that the ST/HR slope and ST-segment deviation of the 12-lead ECG are not able to indicate extent of ischemic injury or number of vessels occluded.

Adult↗

Accurate detection of coronary artery disease by integrated analysis of the ST-segment depression/heart rate patterns during the exercise and recovery phases of the exercise electrocardiography test.

In this comparative cross-sectional study, we evaluated whether a novel computerized diagnostic variable, ST-segment depression/heart rate ST/HR analysis during both the exercise and postexercise recovery phases of the exercise electrocardiography (ECG) test, can detect coronary artery disease more accurately than methods using either exercise or recovery phase alone. The study population comprised 347 clinical patients referred for a routine bicycle exercise ECG test at Tampere University Hospital, Finland. Of these, 127 had angiographically proven coronary artery disease, whereas 13 had no coronary artery disease according to angiography, 18 had no perfusion defect according to technetium-99m sestamibi single-photon emission computed tomography, and 189 were clinically normal with respect to cardiac diseases. For each patient, the maximum values of the ST/HR hysteresis, ST/HR index, end-exercise ST depression, and recovery ST depression were determined from the Mason-Likar modification of the standard 12-lead exercise electrocardiogram [aVL, aVR, and V1 excluded]. The diagnostic performance of these continuous diagnostic variables was compared by means of receiver-operating characteristic analysis. The area under the receiver-operating characteristic curve of the ST/HR hysteresis was 89%, which was significantly larger than that of the end-exercise ST depression (76%, p < or = 0.0001), recovery ST depression (84%, p = 0.0063), or ST/HR index (83%, p = 0.0023), indicating superior diagnostic performance of the ST/HR hysteresis independent of the partition value selection. In conclusion, computerized analysis of the HR-adjusted ST depression pattern during the exercise phase, integrated with the HR-adjusted ST depression pattern during the recovery phase after exercise, can significantly improve the diagnostic performance and clinical utility of the exercise ECG test for the detection of coronary artery disease.

Adult↗