PubMed Health⌕ Search

Biomedical subjects

J W Babich

Publications and source records attributed to J W Babich.

58 records · Page 4Linked to original sources

An improved tungsten-178/tantalum-178 generator system for high volume clinical applications.

Clinical utilization of the multiwire gamma camera (MWGC) requires low-energy radionuclides. The short-lived (9.3 min) tantalum-178 (178Ta) is ideally suited for the MWGC and can be produced from long-lived (21.7 day) tungsten-178 (178W) by a previously reported 178W/178Ta generator. This generator, however, is limited by sharp increase in breakthrough after elution of only 30-60 column-volumes. To optimize the 178W/178Ta generator for clinical use, varying eluant acid concentrations were evaluated. A reduced (from 0.1 to 0.03N) HCI concentration in the eluant, coupled with low operating temperatures (3 to 5 degrees C) allowed high (40 to 60%) 178Ta yield. Minimal 178W breakthrough (less than .01%) resulted, even after elution of more than 200 column-volumes. Each of six tested generators provided sterile, high activity (up to 100 mCi) 178Ta elutions for more than 30 days. Radiation dosimetry was estimated utilizing both human and animal biodistribution data. The whole body (critical organ) dose in adults and neonates were 1/20 (1/21) and 1/19 (1/50) respectively relative to that of technetium-99m (99mTc) as sodium pertechnetate. The optimized 178W/178Ta generator provides a commercially practical, safe source of low-energy radioisotope for the MWGC with substantial dosimetry advantages over 99mTc.

Animals↗

99mTc-HMPAO as a tumour blood flow agent.

The cerebral blood flow agent, 99mTc-HMPAO ('CeretecTM') has been investigated to see if it can be used to estimate tumour blood flow. Its distribution in Balb/c mice bearing either a subcutaneously implanted sarcoma or a plasmacytoma has been shown to be similar to that of 86RbCl. The changes in peripheral blood flow caused by the beta-blocker, propranolol, and by Nembutal anaesthesia, are manifested equally by 99mTc-HMPAO and 86Rb. We conclude, therefore, that HMPAO may be useful in estimating tumour perfusion.

Animals↗

An antibody-desferrioxamine conjugate labelled with 67Ga.

The optimum conditions for producing a 67Ga labelled antibody-desferrioxamine conjugate were determined. The mouse monoclonal antibody LICR-LON-M8 was coupled to the metal chelating compound desferrioxamine (DFO) using glutaraldehyde (GLUT). A DFO:GLUT:M8 molar ratio of 500:150:1 gave an immunoreactive antibody with low amounts (less than 5%) of high molecular weight polymer. The labelling efficiency with 67 Ga was greater than 90%, with a specific activity of 2-4 MBq/mg antibody. This 67Ga labelled antibody is suitable for evaluation as a diagnostic imaging agent.

Animals↗

A gamma camera for medical applications, using a multiwire proportional counter.

A multiwire proportional counter gamma camera, specifically designed for nuclear medicine applications, is portable and weighs less than 50 lb including shielding and collimator. The basic operating characteristics have been investigated with various radioactive sealed sources. The camera demonstrates a peak count rate of 850,000 cps, an intrinsic spatial resolution of 2.5 mm, and excellent image uniformity when used with x-ray sources in the range of 22-81 keV. Tests of the device with Ta-178--a very promising, short half-life (9.3 min), low-energy radionuclide--using 20 mCi injections provided images of quality comparable to those obtained from 15 mCi Tc-99m studies with conventional imaging devices. The camera used with Ta-178 offers particular promise in first-pass nuclear cardiology studies. Considerably improved study quality will likely result in this area because of the increased injectable dose levels offered by Ta-178 combined with the high-count rate capability and improved resolution.

Americium↗