PubMed Health⌕ Search

Biomedical subjects

J W Bulte

Publications and source records attributed to J W Bulte.

38 records · Page 3Linked to original sources

Comparison of T2 relaxation in blood, brain, and ferritin.

T2 was measured in samples of human blood and monkey brain over a field range of 0.02-1.5 Tesla, with variable interecho times, and was compared with previous data on ferritin solutions (taken with the same apparatus). 1/T2 in deoxygenated blood increased quadratically with field strength, as noted previously, but in brain gray matter the increase was linear, as also was the case in ferritin solution. In both deoxygenated blood and gray matter, 1/T2 increased with interecho time, but appeared to level off at times around 50 msec, as expected from the theory of diffusion through magnetic gradients. Diffusion times estimated by using the chemical exchange approximation were 3.4 msec for deoxygenated blood and 5.7 msec for the globus pallidus. The quadratic field dependence in blood is consistent with this same theory, but the linear dependence in brain tissue and in ferritin solutions remains unexplained.

Animals↗

The quantitative relation between T1-weighted and T2-weighted MRI of normal gray matter and iron concentration.

A retrospective analysis of 158 T1-weighted and T2-weighted MRI scans of normal brains at 0.5 and 1.5 Tesla was performed. Signal intensities in the frontal cortex, caudate nucleus, putamen, and globus pallidus were divided by those of frontal white matter; and these gray/white ratios were correlated with iron concentration, estimated from the anatomical region and age of the patient. Intraregional plots were also made of gray/white ratio versus age for the 1.5 Tesla scans. The changes in both T1-weighted and T2-weighted ratios were consistent with the hypothesis that 1/T1 and 1/T2 vary linearly with iron concentration, and the corresponding coefficients, determined separately from the interregional and intraregional plots, were generally in agreement. Furthermore, the variability of the MRI ratios at 1.5 Tesla was consistent with expected iron variability except for the cortex, in which partial volume errors due to sulci and white matter caused increased variations. The MRI results agreed well with in vitro data on T1 and T2 in tissue specimens and with other MRI studies. When compared with T1 and T2 in ferritin solution, a significant "tissue relaxation enhancement" was found, attributable to slower diffusion and clustering of ferritin in tissue.

Adult↗