PubMed Health⌕ Search

Biomedical subjects

J W Durkee

Publications and source records attributed to J W Durkee.

5 recordsLinked to original sources

A fully coupled binary biochemical reactive-diffusion model with analytic solution.

Coupled multicomponent biochemical reactive diffusion underlies a variety of biological signalling processes and pharmacokinetic applications, such as paracrine signalling involving "cocktails" comprised of growth promoter/inhibitor factors and proteases associated with tumor angiogenesis, invasion and metastasis, extravascular drug delivery, and polymeric controlled-release drug codelivery design. Here, we present a model and develop a new analytic solution to illustrate the spatiotemporal behavior associated with fully coupled binary biochemical reactive diffusion. The complete coupling renders the solution appreciably more complex in structure and behavior than solutions for unicomponent or partially coupled models. Concentration behavior is illustrated by the computational simulation of binary-species tumor angiogenesis factor reactive-diffusion in the extravascular tissue matrix. The computational results indicate that (a) steady-state concentration profiles are achieved within 1 h of a change in factor production; (b) in the steady state, the spatial profiles of the two components tend to be similar; (c) exceedingly steep concentration gradients, involving several orders-of-magnitude differences in concentration over a few tenths of a millimeter, can occur in the vicinity of boundary sources due to inter-species reaction; (d) the concentration profiles of the two species differ from unicomponent predictions due to the simultaneous mass interchange between the two species. The analytic solution predictions are also used to provide a first-ever validation of a time-dependent, binary-component Crank-Nicholson numerical solution. The ability to quantitatively model interacting and often strongly varying concentration levels as a function of time and position can serve as a powerful complementary tool to experimental analyses for assessing disease state and interventional pharmacological efficacy, especially when the spatial scales on which in vivo behavior occurs taxes the limits of imaging capabilities.

Angiogenesis Inducing Agents↗

SPECT electronic collimation resolution enhancement using chi-square minimization.

An electronic collimation technique is developed which utilizes the chi-square goodness-of-fit measure to filter scattered gammas incident upon a medical imaging detector. In this data mining technique, Compton kinematic expressions are used as the chi-square fitting templates for measured energy-deposition data involving multiple-interaction scatter sequences. Fit optimization is conducted using the Davidon variable metric minimization algorithm to simultaneously determine the best-fit gamma scatter angles and their associated uncertainties, with the uncertainty associated with the first scatter angle corresponding to the angular resolution precision for the source. The methodology requires no knowledge of materials and geometry. This pattern recognition application enhances the ability to select those gammas that will provide the best resolution for input to reconstruction software. Illustrative computational results are presented for a conceptual truncated-ellipsoid polystyrene position-sensitive fibre head-detector Monte Carlo model using a triple Compton scatter gamma sequence assessment for a 99mTc point source. A filtration rate of 94.3% is obtained, resulting in an estimated sensitivity approximately three orders of magnitude greater than a high-resolution mechanically collimated device. The technique improves the nominal single-scatter angular resolution by up to approximately 24 per cent as compared with the conventional analytic electronic collimation measure.

Algorithms↗

Analytic treatment of resolution precision in electronically collimated SPECT imaging involving multiple-interaction gamma rays.

The widely applied single-interaction analytic expression characterizing the energy resolution component of the angular resolution precision for an electronically collimated point source is extended to include multiple-interaction Compton scatter sequences as well as sequences terminated by photoelectric absorption. The analytic formulation is developed using the statistical variance of the mean for components comprising composite, multivariate resolution precision estimators. It is demonstrated that enhanced resolution precision in the incident interaction scatter angle is attained when use is made of information from multiple interactions. An improvement in the resolution precision of up to approximately 40% is observed for triple Compton scatter. Comparison of the analytic estimates with Monte Carlo/chi-square results shows good agreement.

Chi-Square Distribution↗