Patient selection reduces thrombotic complications of emergent stenting for failed PTCA.

A comparison of consecutive initial and later patients receiving emergent coronary artery stents to salvage failed PTCA procedures was made to determine whether experience with this procedure can improve patient outcome. Twenty-six consecutive patients underwent emergent, unplanned implantation of one or more Palmaz-Schatz coronary stents at our institution over a 3-1/2 year period. Indications for stent insertion included impending vessel closure (decrease in TIMI flow grade and clinical evidence of ischemia) or acute occlusion (TIMI flow grade 0 or 1 and > or = 99% stenosis) after PTCA. Immediate and final success (30 day) were determined, and the results in the first (Initial) 13 patients were compared to the remaining (Later) 13 patients. Baseline characteristics of the study population included a male predominance (69%) with a mean (+/- SD) age of 57 +/- 10 years. Conventional balloon PTCA was performed in all three native coronary arteries with an increase in mean percentage stenosis from 76 +/- 13 to 85 +/- 14% (P < 0.05). Twelve patients developed acute occlusion and 14 patients impending closure after PTCA due to the appearance of thrombus (12%), dissection (46%), or both (35%). Palmaz-Schatz stents were successfully inserted in all patients restoring TIMI grade 3 antegrade flow; however, major complications developed in almost 50% of patients. Comparison of initial and later patients showed no differences in demographic or pre-PTCA angiographic characteristics. Later patients had less severe stenoses post-PTCA (before stenting) and were less likely to have thrombus present at the angioplasty site (15% vs. 77%, P < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Emergent use of balloon-expandable coronary artery stenting for failed percutaneous transluminal coronary angioplasty.

BACKGROUND: The balloon-expandable intracoronary stent developed by Palmaz and Schatz is undergoing clinical evaluation for use in unfavorable anatomic situations and in the prevention of restenosis. Because the stent's mechanism of action would suggest effectiveness in salvaging certain percutaneous transluminal coronary angioplasty (PTCA) failures, we retrospectively examined the results of emergency unplanned coronary artery stenting for failed PTCA procedures, including acute occlusion. METHODS AND RESULTS: The study population consisted of all US patients receiving emergency unplanned stent implantation in a nonrandomized fashion at seven centers over a 2 1/2-year period (n = 56). All available medical records and angiograms were reviewed to determine retrospectively the reason for stenting: Group 1 consisted of 23 patients with a suboptimal angioplasty result; group 2 included patients with evidence of impending vessel closure after PTCA (n = 15); and group 3 were patients with frank acute occlusion after PTCA (n = 18). The immediate and final (30-day) results of stenting were examined with respect to major complications, which included death, need for coronary artery bypass graft surgery, and occurrence of myocardial infarction. Finally, restenosis rates (greater than or equal to 50% stenosis) based on follow-up angiography were calculated. Baseline characteristics of the study population included a mean +/- SD age of 58 +/- 11 years and a large prevalence of angiographic characteristics generally considered unfavorable for PTCA, which include lesion eccentricity (49%), intimal dissection (9%), or angiographically visible thrombus (6%). After conventional balloon angioplasty, there was an increased incidence of intimal dissection (74%) and thrombus formation (38%), and overall stenosis severity was unchanged (75 +/- 12% versus 70 +/- 27%, p = NS). Successful stent deployment was achieved in 55 (98%) of 56 patients with initial success (freedom from death, surgery, and infarction) in 52 (93%) of 56 patients. The success rate at 1 month fell to 71% primarily because of the occurrence of subacute stent thrombosis (16%) and its associated complications. Overall, major complications occurred in 16 (29%) of 56 patients within 30 days. The only predictor of subacute stent thrombosis in multiple stepwise logistic regression analysis was the presence of angiographically visible thrombus after stenting (p = 0.03). Angiographic restenosis was documented in eight (23%) of 35 eligible patients. CONCLUSIONS: Emergency stenting may be a useful and effective treatment for failed angioplasty. High initial success rates (greater than 90%) can be achieved, but subsequent complications, often related to subacute thrombosis, occur in a substantial portion of patients. Patients who receive stents on an emergency basis, particularly those with previous acute occlusion, should be considered to be at greater than usual risk for complications and receive more careful anticoagulation and follow-up.

Aged

Restenosis after placement of Palmaz-Schatz stents in native coronary arteries. Initial results of a multicenter experience.

BACKGROUND: Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. METHODS AND RESULTS: To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in the first group of patients selected for this procedure, clinical and quantitative angiographic data from 206 consecutive patients (221 stenoses) with successful stent placement (diameter stenosis < 50%) were analyzed. Six patients (2.9%) had thrombosis-mediated stent closure within 1 month after stent placement and were excluded from long-term angiographic follow-up. One hundred eighty-one (91%) of the remaining 200 patients had angiography at 5.8 +/- 2.1 months. Patients with and without follow-up did not differ in any baseline characteristic; in particular, history of restenosis at the site stented (73% versus 65%), placement of multiple overlapping stents (17% versus 20%), and mean poststent diameter stenosis (16 +/- 12% versus 14 +/- 12%). The overall incidence of restenosis (diameter stenosis > or = 50% at follow-up) in this group at high risk for restenosis was 36% (95% confidence interval, 29-43%) on a per-stenosis basis. The incidence of restenosis when a single stent was placed was 30% (95% confidence interval, 23-37%). Risk was dependent upon a history of restenosis (present versus absent 36% versus 16%, p = 0.02) and upon whether or not a poststent stenosis < or = 0% was achieved (6% versus 33%, p = 0.02). When multiple overlapping stents were placed, restenosis occurred at 64% of sites, and placement of multiple stents was discouraged during the later phases of this study as these results became apparent. CONCLUSIONS: Although multiple stents appear to yield a poor long-term result, placement of single stents may offer a benefit compared with standard coronary angioplasty, particularly if an excellent angiographic result can be obtained in patients without prior restenosis. Further randomized trials in such patients are needed.

Coronary Angiography

Effect of intracoronary stenting on intimal dissection after balloon angioplasty: results of quantitative and qualitative coronary analysis.

The effect of the Palmaz-Schatz stent on the angiographic appearance and residual luminal stenosis in patients with intimal dissection after balloon angioplasty was evaluated in 84 consecutive patients (90 lesions). Coronary angiography was performed before angioplasty, after conventional angioplasty and after stent implantation. The degree of intimal disruption was assessed as follows: grade 0, no dissection; grade 1, simple dissection (intraluminal linear defect or extraluminal cap extravasation); or grade 2, complex dissection (nonlinear spiral defect or luminal defect with multiple irregular borders). Quantitative coronary analysis of digitized cineangiograms was performed with use of a computerized automatic edge detection algorithm. After balloon angioplasty, 31 (34%) of 90 lesions demonstrated intimal dissection (18 simple, 13 complex). After stent implantation, intimal dissection improved by greater than or equal to 1 grade in 29 (94%) of the 31 lesions with 27 (87%) reduced to grade 0 (that is, no dissection). Dissection grade improved after stenting in 16 (89%) of 18 simple dissections and in all 13 complex dissections. Mean diameter stenosis was 77 +/- 17% before angioplasty, 47 +/- 17% after angioplasty and 14 +/- 10% after stenting (before angioplasty vs. after angioplasty and after angioplasty vs. after stenting, p less than 0.0001). In conclusion, intracoronary stenting is effective in reducing the residual luminal stenosis and in improving the angiographic appearance of intimal dissections after conventional balloon angioplasty.

Adult

Choice of contrast agents for cardiac angiography: review and recommendations based on clinically important distinctions.

Low osmolal contrast agents (LOCA) are measurably superior to high osmolal contrast agents (HOCA) in a number of properties. However, LOCA are substantially more expensive than HOCA, and universal use of LOCA for cardiac angiography would strain the health care budget. Therefore, the choice to use LOCA in place of HOCA should be based on clinically important differences. Review of available published data suggests that HOCA can be used safely and effectively for cardiac angiography in patients with mild or moderately severe heart disease. When HOCA are used, those that do not bind calcium should be chosen as they cause fewer clinically important adverse reactions than those that do bind calcium. Use of LOCA may offer added safety in high risk patients, although to date, this conclusion has not been proved with clinical experience. Nonionic LOCA may be safer to use than ionic LOCA.

Angiocardiography

Clinical and angiographic determinants of primary coronary angioplasty success. M-HEART Investigators.

Clinical and anatomic determinants of the initial success of percutaneous transluminal coronary angioplasty were prospectively evaluated in 826 patients enrolled in the Multi-Hospital Eastern Atlantic Restenosis Trial (M-HEART). The 639 men and 187 women ranged in age from 31 to 85 years. Successful angioplasty (residual stenosis less than 50% and no major complications) was achieved in 886 (88.6%) of 1,000 lesions. Success rates were uniform among the eight individual centers. Outcome was not influenced by gender, age or other clinical features, including severity and duration of angina, prior myocardial infarction, rest pain, transient ST segment elevation, history of smoking or diabetes. In contrast, procedural outcome was significantly associated with lesion-specific angiographic factors. Stenoses 60% to 74%, 75% to 89%, 90% to 99% and 100% were associated with success rates of 96%, 90%, 84% and 69%, respectively (p less than 0.001). Angioplasty was less successful in calcified than in noncalcified lesions (82% versus 90%, p less than 0.01), in thrombotic than in nonthrombotic lesions (82% versus 90%, p less than 0.05) and in lesions in the right coronary artery than in other vessels (84% versus 90%, p less than 0.01). Outcome was not related to other anatomic variables, including lesion location (proximal versus distal), vessel size, eccentricity, stenosis length or translesional gradient. By multivariate logistic regression, preangioplasty percent stenosis, right coronary artery location and lesion calcification were demonstrated to be significant independent predictors of angioplasty success. Alternative clinical and angiographic variables did not contribute to this regression model.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary

Restenosis after coronary angioplasty: a multivariate statistical model to relate lesion and procedure variables to restenosis. The M-HEART Investigators.

The Multi-Hospital Eastern Atlantic Restenosis Trial group obtained follow-up angiography in 510 patients with 598 successfully dilated coronary lesions who were enrolled in a controlled trial of the effects of a single dose of 1 g of methylprednisolone on restenosis after coronary angioplasty. The overall restenosis rate was 39.6%. The strongest univariate relations to the restenosis rate were found for lesion location (saphenous vein graft, 68%; left anterior descending artery, 45%; left circumflex artery and right coronary artery, 32%; p = 0.002); lesion length (less than or equal to 4.6 mm, 33%; greater than 4.6 mm, 45%; p = 0.001); percent stenosis before angioplasty (less than or equal to 73%, 25%; greater than 73%, 43%; p = 0.005), percent stenosis after angioplasty (less than or equal to 21%, 33%; greater than 21%, 46%; p = 0.017) and arterial diameter (less than 2.9 mm, 44%; greater than or equal to 2.9 mm, 34%; p = 0.036). Two multivariate models to predict restenosis probability were developed with use of stepwise logistic regression. The preprocedural model, which included only variables whose values were known before angioplasty, entered lesion length, vein graft location, left anterior descending artery location, percent stenosis before angioplasty, eccentric lesion and arterial diameter. The postprocedural model, which also included variables whose values were known after angioplasty was performed, was similar to the preangioplasty model except that it also entered postangioplasty percent stenosis and "optimal" balloon sizing but did not enter eccentric lesion. These data indicate that the probability of restenosis after angioplasty is determined predominantly by the characteristics of the lesion being dilated. They are consistent with the known intimal proliferative mechanism of restenosis, offer a means of identifying lesions at unusually high or low risk of restenosis, and of predicting the likelihood that a particular lesion will restenose after angioplasty and provide a rationale for stratification by restenosis probability in the design of future studies of restenosis.

Angioplasty, Balloon, Coronary

Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study.

Stenting of native coronary arteries with a balloon-expandable stent was attempted in 226 patients after elective angioplasty. Delivery of the device was successful in 213 (94%) of the patients. Of these, 39 received aspirin and dipyridamole only (group 1) and 174 received aspirin, dipyridamole, and warfarin for 1-3 months (group 2). There was no abrupt closure (less than or equal to 1 day) or perioperative death in either group. In-hospital or perioperative complications in group 1 compared with group 2 were as follows: subacute closure (1-14 days), seven (18%) patients versus one (0.6%) patient, respectively, p less than 0.0001; myocardial infarction, five (13%) patients versus one (0.6%) patient, respectively; condition requiring urgent bypass surgery, one (2.5%) patient versus no patients, respectively. Thus, the incidence of major complications such as death, myocardial infarction, or a condition requiring urgent bypass surgery was 15% in group 1 and 0.6% in group 2. Clinical follow-up revealed that 92% of the patients were asymptomatic at 3 months after stenting compared with 6% before stenting (p less than 0.0001). Of the 13 patients who were symptomatic, nine underwent cardiac catheterization and, ultimately, successful elective coronary angioplasty or bypass surgery. We conclude that a high delivery success rate can be expected with this device and that clinical thrombosis is less frequent in anticoagulated patients than in nonanticoagulated patients. Furthermore, in this selected patient population, coronary stenting results in a low incidence of in-hospital and perioperative complications. Clinical success, defined by absence of symptoms, appears to be sustained at 3 months.

Angioplasty, Balloon, Coronary

Cardiovascular effects of iodinated contrast agents.

The ideal intravascular contrast agent would be biologically inert and have no pharmacologic actions. Pharmacologic actions of currently used radiographic contrast agents are determined principally by 3 physicochemical properties of the iodine-bearing molecule and its formulation: osmolality, sodium concentration and calcium-binding properties. Within this framework, the calcium-binding 1.5 ratio agents have the most marked effects, and the 3.0 ratio nonionic agents the least, with the noncalcium-binding formulations of 1.5 ratio agents and ioxaglate (the only 3.0 ratio ionic agent) in between. Differences in hemodynamic effects are predominantly related to osmolality with the 3.0 agents causing less hemodynamic disturbance. The magnitude of difference is small enough that the 3.0 ratio agents have no important clinical advantage when used in patients with good or moderately impaired left ventricular function. However, the difference may be important in patients with severely impaired circulatory performance. The principal electrophysiologic differences are between the calcium-binding 1.5 ratio agents (which are associated with a clear-cut greater frequency of ventricular fibrillation during coronary injection than the noncalcium-binding 1.5 ratio agents) and the 3.0 ratio agents. There is no justification for the use of calcium-binding 1.5 ratio agents, since noncalcium-binding formulations of the same molecule are available at the same price. The circulatory reserve of most patients makes the differences between 3.0 ratio agents and noncalcium-binding 1.5 ratio agents clinically unimportant. In view of the substantial price disparity between 1.5 ratio and 3.0 ratio agents, noncalcium-binding 1.5 ratio agents are appropriate for patients with good circulatory performance and 3.0 ratio agents are best reserved for patients with impaired circulatory performance.(ABSTRACT TRUNCATED AT 250 WORDS)

Contrast Media

Patient-related variables and restenosis after percutaneous transluminal coronary angioplasty--a report from the M-HEART Group.

As part of a randomized prospective study designed to investigate the restenosis process after percutaneous transluminal coronary angioplasty (PTCA), the relation between patient-related variables and restenosis rate was examined. A total of 722 patients had successful PTCA. Angiographic follow-up was scheduled for 6 +/- 2 months after the procedure and achieved in 510 patients (71%), yielding 598 lesions for analysis. The overall restenosis rate was 40%. The rate was higher in patients undergoing early restudy for a clinical event than in those undergoing routinely scheduled follow-up restudy (71 vs 22%, p less than 0.0001). Age, sex, cigarette smoking history, diabetes mellitus and history of previous myocardial infarction were not associated with restenosis rate. Angina duration and severity before PTCA were also unrelated to restenosis rate. In summary, these variables, many of which have been previously implicated in restenosis, were not found to be predictors of restenosis. The decision to perform PTCA in individual patients should not be negatively influenced by the presence of these factors.

Adult

Safety of cardiac angiography with conventional ionic contrast agents. The Philadelphia Area Contrast Agent Study.

To characterize the frequency of adverse reactions to conventional ionic contrast agents, data describing the frequency of such reactions were gathered from 4,630 diagnostic cardiac angiographic procedures. The patient population had a large prevalence of severe or unstable cardiac disease (56% had New York Heart Association class III, IV or V, 12.6% had left ventricular end-diastolic pressure greater than 25 mm Hg and 34% had 3-vessel or left main coronary artery disease). The overall minor adverse reaction rate was 14.2%. Major adverse reactions (requiring treatment) occurred in 61 (1.3%) of procedures. All adverse reactions were managed successfully and there were no deaths. Adverse reactions were more frequent in patients with higher New York Heart Association classes and with elevated left ventricular end-diastolic pressure. The adverse reaction rate was not increased in patients with more extensive coronary artery disease, reduced left ventricular ejection fraction or reduced cardiac index. The overall adverse reaction rate was probably influenced by physician behavior. Smaller volumes of contrast agent were administered to patients with more severe cardiac disease. Six percent of procedures were abbreviated either because of an adverse reaction or of concern that a reaction might occur if the procedure were continued. As a result, the diagnostic data obtained were judged to be inadequate in 0.8% of procedures. These data demonstrate that appropriate operator caution within the highly monitored environment of the cardiac catheterization laboratory allows cardiac angiography to be performed safely with conventional ionic contrast agents in most patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

Influence of heparin therapy on percutaneous transluminal coronary angioplasty outcome in patients with coronary arterial thrombus.

The clinical and angiographic outcome of 18 patients with coronary thrombus undergoing percutaneous transluminal coronary angioplasty without antecedent heparin therapy was compared to that of a group of 35 patients receiving pre-procedural heparin therapy. The former group had a significant reduction in angiographic success (61 vs 94%, p less than 0.05) and a significant increase in immediate postprocedural thrombotic arterial occlusion (33 vs 6%, p less than 0.05). This difference existed despite equivalent frequencies of antiplatelet therapy. Prolonged intravenous heparin therapy before angioplasty in the setting of coronary thrombus improves the overall success rate and lessens the likelihood of periprocedural coronary arterial thrombosis.

Angiography

Accuracy of subjective and computer-assisted assessments of angiographic left ventricular regional wall motion.

To evaluate the accuracy of angiographic methods for analysis of left ventricular regional wall motion, we measured the ability of a carefully performed subjective analysis (three independent observers) and that of three computer-assisted methods (centerline, radial, and area) to detect the presence of significant coronary artery disease. Normal ranges were established in 90 studies showing normal wall motion, and accuracy was tested in a second, consecutive series of 43 ventriculograms. The results show that the subjective method best separated those regions with from those without significant coronary disease. The subjective method also demonstrated sensitivity comparable to the centerline and radial methods. Among the computer-assisted methods, the area method was least sensitive but most specific for both anterior and inferior region coronary disease. The centerline and radial methods were highly sensitive, but less specific. When coronary disease was defined by electrocardiographic Q-waves, the area method had superior accuracy. Further analysis showed the following: 1) For the centerline and radial methods, long-axis reregistration of the end-systolic frame resulted in loss of sensitivity but increased specificity for anterior wall coronary disease, and little change in analysis of the inferior wall; 2) inclusion or exclusion of the apex had little effect on predictive accuracy for anterior wall coronary disease; 3) as expected, sensitivity and specificity results of all methods were dependent on the selection of a normal range cutoff value; but when performance was optimized, the subjective and area methods had a higher overall predictive accuracy than the centerline method; 4) It is likely that all three computer-assisted methods could be calibrated to give indications of degrees of hypokinesis, as their results correlated well with subjective observers' evaluations over the entire range of scores. These results should assist in selection of the optimal method for regional wall motion analysis in clinical and research applications. As currently applied, the area method is the most specific of the computer-assisted methods tested; the centerline and radial methods have highest sensitivity and therefore are most suited to detection of mild degrees of hypokinesis.

Angiocardiography

A controlled trial of corticosteroids to prevent restenosis after coronary angioplasty. M-HEART Group.

A multicenter, double-blind, placebo-controlled trial was conducted to determine if corticosteroids influence the development of restenosis after successful percutaneous transluminal coronary angioplasty (PTCA). Either placebo or 1.0 g methylprednisolone (steroid) was infused intravenously 2-24 hours before planned PTCA in 915 patients. The PTCA patient success rate was 87% (mean) in the eight centers. There were no differences in clinical or angiographic baseline variables between the two groups. End-point analysis (angiographic restenosis, death, recurrent ischemia necessitating early restudy, and coronary artery bypass graft surgery) showed that there was no significant difference comparing placebo- with steroid-treated patients. Angiographic restudy showed the lesion restenosis rate to be 39% (120 of 307 lesions) after placebo and 40% (117 of 291) after steroid treatment (p = NS). We conclude that pulse steroid pretreatment does not influence the overall restenosis rate after successful PTCA.

Angioplasty, Balloon, Coronary