PubMed Health⌕ Search

Biomedical subjects

J W Monroe

Publications and source records attributed to J W Monroe.

5 recordsLinked to original sources

Assessment of internal auditory canal tumors: a comparison of contrast-enhanced T1-weighted and steady-state T2-weighted gradient-echo MR imaging.

BACKGROUND AND PURPOSE: Although contrast-enhanced T1-weighted MR imaging is the standard of reference for diagnosing tumor in the cerebellopontine angle, high-resolution T2-weighted imaging may show more details of the seventh and eighth cranial nerve branches, resulting in more accurate tumor volume measurements. The purpose of this study was to compare two MR sequences for their ability to delineate internal auditory canal tumors. METHODS: Twenty-seven ears in 21 patients with 16 confirmed schwannomas were studied with the 3D T2-weighted prototype segment-interleaved motion-compensated acquisition in steady state (SIMCAST) and the T1-weighted contrast-enhanced spoiled gradient-echo (SPGR) techniques. Twenty-eight axial sections were acquired using parameters of 17/3.3 (TR/TE), a 40 degrees flip angle, a 20 x 15-cm or 22 x 16-cm field of view (FOV), a 512 x 256 matrix, and a 0.4- or 1.2-mm section thickness for the SIMCAST technique, and 30/4.2, a 30 degrees flip angle, a 20 x 20-cm FOV, a 512 x 288 matrix, and a 1.5-mm section thickness for the SPGR technique. Tumor appearance and depiction of surrounding anatomy, including the cranial nerves, were evaluated. Tumor volumes were measured by manual tracing. RESULTS: Both sequences clearly identified tumors that ranged in size from 0.06 to 3.0 cm3. Measurements on both sequences agreed, on average, within 14%. The information from both sequences was complementary. SIMCAST usually delineated the CSF spaces better, whereas SPGR more clearly showed the tumor/brain boundary. CONCLUSION: SIMCAST and SPGR are suitable for tumor detection and volume measurements. SPGR has somewhat better contrast, but SIMCAST excels at depicting the surrounding anatomy and tumor involvement of the seventh and eighth cranial nerves.

Adolescent↗

Phased array coils for upper extremity MRA.

A phased array coil was constructed for imaging the upper extremity vasculature for patients undergoing dialysis treatment. The phased array coil exhibits improved signal-to-noise ratio (SNR) over the body coil and allows imaging of the entire upper extremity. SNR as a function of depth was measured on a homogeneous phantom with the arm coil and compared with the body coil. Near the coil there is an improvement of a factor of 7 and at a depth of approximately 6-7 cm, there is an improvement of factor 2. In vivo SNR measurements resulted in similar improvements. Images of the upper extremity vasculature of healthy volunteers were generated using 2D-time-of-flight (2DTOF) angiography. Blood flow velocity was assessed in a CINE-phase contrast study.

Arm↗

Phased array RF coils for high-resolution MRI of the inner ear and brain stem.

OBJECTIVE: The spatial resolution in MRI is predominantly limited by the available signal-to-noise ratio (S/N). To increase the S/N, a four coil phased array consisting of bilateral pairs of semioval coils was constructed for high resolution imaging of the temporal bone and brainstem. MATERIALS AND METHODS: Coil sizes of 10 x 6 and 6 x 4.5 cm were tested. The S/N values were measured in vivo and with homogeneous phantoms and compared to commercial 3 in receive and quadrature head coils. RESULTS: At a depth of 4-5 cm, phantom studies yielded S/N improvements of a factor of 1.26-1.37 with the large array compared to the 3 in coil and 2.33-1.74 compared to the head coil. Similar improvements (1.16 and 2.37) were obtained in inner ear images. No further improvement was achieved at this depth with the small array. At a depth of 8 cm, phantom studies yielded similar S/N for the quadrature head coil and two bilaterally placed large array coils, while a factor of 1.27 was obtained in brainstem images. CONCLUSION: The use of phased array coils yields significantly increased S/N and is thus valuable for high resolution MRI.

Brain Stem↗