PubMed Health⌕ Search

Biomedical subjects

J W Verba

Publications and source records attributed to J W Verba.

9 recordsLinked to original sources

Single photon emission computed tomograms of the liver: normal vascular intrahepatic structures.

Because of the high target-to-background contrast obtained with single photon emission computed tomography (SPECT), normal intrahepatic vessels approximately 2 cm in diameter may appear as distinct focal defects in tomographic sections throughout the liver even though normal vessels rarely cause such defects on planar images. To assess this problem, five subjects without evidence of liver disease underwent tomography of the liver with Tc-99m sulfur colloid (TSC) and on a separate occasion tomography of the intrahepatic blood pool with Tc-99m autologous red blood cells (RBC). In each case, well demarcated defects were obvious in contiguous TSC liver tomograms in various planes. Direct comparison with RBC tomograms showed that all of these defects corresponded to intrahepatic veins, typically the right portal vein, its posterior branch, and the left portal vein. Knowledge of the intrahepatic vascular anatomy in a variety of tomographic planes, with examination of each defect in multiple orthogonal planes is necessary to avoid false positive interpretations. In some instances a study with RBC may also be required for more conclusive evaluation of defects seen on TSC liver tomograms.

Diagnostic Errors↗

Monitoring of I-125 contamination using a portable scintillation camera.

A technique has been developed using a portable scintillation camera to monitor I-125 contamination of personnel. The procedure takes less than a minute to complete and can detect 3 nanocuries; its use minimizes dissemination of I-125 throughout the hospital, emphasizes safe iodination practices and proper handling of radioactive materials, and reduces radiation exposure by undetected contamination.

California↗

Noninvasive determination of glomerular filtration rate using x-ray fluorescence.

Accurate glomerular filtration rates (GFR) can be calculated based on the infusion of small amounts of nonradioactive iothalamate and collection of plasma samples for assay by x-ray fluorescence. This innovation permits frequent clearance determinations in patients without the hazard of repeated radiation exposure and without the necessity of catheterization of the bladder for urine samples. Thus, the technique becomes feasible in children, transplant patients, and other needing accurate and frequent GFR determinations.

Animals↗

Serial measurements of left ventricular ejection fraction by radionuclide angiography early and late after myocardial infarction.

The left ventricular ejection fraction was determined serially with radioisotope angiography in 63 patients with acute myocardial infarction. After the peripheral injection of a bolus of technetium-99m, precordial radioactivity was recorded with a gamma scintillation camera and the ejection fraction calculated from the high frequency left ventricular time-activity curve. Since this technique requires no assumptions with respect to left ventricular geometry, it is particularly useful in patients with segmental left ventricular dysfunction. Serial measurements during the first 5 days after hospital admission were made in 50 patients, 30 of whom were studied during the subsequent 2 to 39 months (mean 19.9 months). Late follow-up serial studies were also performed in an additional 13 patients who had only one measurement of the left ventricular ejection fraction during the early postinfarction period. Early after infarction, the left ventricular ejection fraction was normal (more than 0.52) in only 15 of the 63 patients, and averaged 0.52 +/- 0.05 (standard deviation) in the 27 patients with an uncomplicated infarct. The ejection fraction was reduced in 24 patients with mild to moderate left ventricular failure (0.40 +/- 0.05, P less than 0.0001) and in the 12 patients with overt pulmonary edema (0.33 +/- 0.07, P less than 0.0001). In 35 patients the ejection fraction correlated with the mean pulmonary arterial wedge pressure (r = 0.72). In 15 patients with normal left ventricular wall motion by heart motion videotracking, the ejection fraction was significantly higher (0.53 +/- 0.08) than in the 26 patients with regional left ventricular dysfunction (0.41 +/- 0.10, P less than 0.0001). During the early postinfarction period, the left ventricular ejection fraction improved in 55 percent of patients and remained unchanged or decreased in 45 percent. A further increase in the ejection fraction was noted in 61 percent of patients during the late follow-up period. Patients with an initially low or decreasing ejection fraction had a significantly greater incidence of early mortality and left ventricular dysfunction (P less than 0.02) than those whose ejection fraction was normal or improved to normal early after infarction. These data indicate that the ejection fraction is a sensitive indicator of left ventricular function after acute myocardial infarction and that serial measurements are helpful in predicting early mortality and morbidity.

Acute Disease↗

Nontraumatic determination of left ventricular ejection fraction by radionuclide angiocardiography.

Previous reports have suggested that left ventricular ejection fraction can be assessed by recording the passage of peripherally administered radioactive bolus through the heart. The accuracy and validity of this technique were examined in 20 patients undergoing diagnostic cardiac catheterization. 99m-Tc-human serum albumin was injected via a central venous catheter into the superior vena cava and precordial activity recorded with a gamma scintillation camera interfaced to a small digital computer. A computer program was designed to generate time-activity curves from the left ventricular blood pool and to calculate left ventricular ejection fractions from the cyclic fluctuations of the left ventricular time-activity curve which correspond to left ventricular volume changes during each cardiac cycle. The results correlated well with those obtained by biplane cineangiocardiography (r equals 0.94) and indicated that the technique should allow accurate and reproducible determination of left ventricular ejection fraction. The findings, however, demonstrated that the time-activity curve must be generated from a region-of-interest which fits the left ventricular blood pool precisely and must be corrected for contributions arising from noncardiac background structures. This nontraumatic and potentially noninvasive technique appears particularly useful for serial evaluation of the acutely ill patient and for follow-up studies in nonhospitalized patients.

Adult↗

Automatic analysis of left ventricular ejection fraction using stroke volume images.

The purpose of this study was to analyze, validate, and report on an automatic computer algorithm for analyzing left ventricular ejection fraction and to indicate future applications of the technique to other chambers and more advanced measurements. Thirty-eight patients were studied in the cardiac catheterization laboratory by equilibrium radionuclide ventriculography and concurrent contrast ventriculography. The temporal and spatial behavior of each picture element in a filtered stroke volume image series was monitored throughout the cardiac cycle. Pixels that met specific phase, amplitude, and derivative criteria were assigned to the appropriate chamber. Volume curves were generated from regions of interest for each chamber to enable calculation of the left ventricular ejection fraction. Left ventricular ejection fractions showed a good correlation (r = 0.89) between the two techniques. Ejection fractions ranged between 0.12 and 0.88, showing a wide range of application. It is concluded that automatic analysis of left ventricular ejection fraction is possible using the present algorithm and will be useful in improving the reproducibility and providing more accurate information during exercise protocols, pharmaceutical interventions, and routine clinical studies.

Cardiac Output↗

Effect of patient imaging angle on apparent cardiac volumes and the potential impact on measurement of valvular regurgitant fractions.

The accurate measurement of cardiac chamber volume is of major importance in assessing cardiac performance. Accurate equilibrium radionuclide volume estimations are difficult to obtain, due to the geometry of the chambers, and the physical characteristics of the imaging system. The purpose of this study was to examine the effects of imaging projections on relative cardiac chamber volumes, indexes, and stroke volume ratios. Twenty-two male patients, free of clinical evidence of disease, were studied. A series of four 2-minute acquisitions were made with the patient successively imaged in the anterior, 30 degrees left anterior oblique (LAO), 45 degrees LAO, and 60 degrees LAO projections with 15 degrees of caudal inclination. Filtered stroke volume and original images were used by the operator to assign right ventricular (RV), left ventricular (LV), and a combined right and left ventricular (TOT) regions-of-interest. From the data we determined end-diastolic counts (EDC), end-systolic counts (ESC), stroke counts (SC), ejection fractions (EF), and R/L stroke count ratios. The following changes were observed as the projection was moved from the anterior to 60 degrees LAO: 1) all RV parameters decreased in value, including, RVEDC (P less than .001), RVESC (P less than .01), RVESC (P less than .01) and RVEF (P less than .001); 2) LVEDC and LVESC (both P less than .01) increased while LVEF decreased (P less than .004); and 3) the R/L stroke count ratio decreased (P less than .001). Variability could be explained by 1) chamber overlap and geometry; 2) patient variability; and 3) intrachamber, interchamber and chest wall photon attenuation and scatter. We suggest that close attention to detail, with computer assistance, to optimally position the patient may reduce the effect of inherent limitations in radionuclide volumetric measurements, thus improving the reliability and usefulness of existing studies.

Aged↗